Permit Application Status

PRRES20216390


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216390
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
12/15/2021
12/20/2021
06/14/2022
05/01/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
CBRUNING@NEWMARKHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,121.65 $1,121.65 Paid 12/20/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/20/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/20/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 12/20/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/20/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/20/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 02/08/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/14/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/13/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/12/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/18/2022 (10:30) 1/18/2022 01/18/2022
Underslab Plumbing Inspection - Residential Failed 2/28/2022 2/28/2022 02/28/2022
Misc
Corrective Action Required
02/28/2022
inspection denied due to lack of erosion control at back of lot
Erosion Control Inspection Residential Failed 2/28/2022 02/28/2022
Misc
Corrective Action Required
02/28/2022
Erosion control required at back of lot
Underslab Plumbing Inspection - Residential Passed 3/2/2022 3/2/2022 03/02/2022
Misc
Resolved
03/02/2022
inspection denied due to lack of erosion control at back of lot
Erosion Control Inspection Residential Partial 3/2/2022 03/02/2022
Misc
Resolved
03/02/2022
Erosion control required at back of lot
Misc
Informational
03/02/2022
EROSION CONTROL BACK IN COMPLIANCE Mitchell Schwarz 03/02/2022 9:30 AM
Sewer Service Inspection - R Passed 3/29/2022 (2:00) 3/29/2022 03/29/2022
Water Service Inspection - R Passed 3/31/2022 (10:30) 3/31/2022 03/31/2022
Erosion Control Inspection Residential Failed 05/13/2022
Misc
Resolved
05/13/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/13/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Mantain silt fence and clean debris from streets
Piers/Caissons Inspection - Residential Failed 6/28/2022 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/28/2022
piers full of water pump out water for inspection
Piers/Caissons Inspection - Residential Passed 6/29/2022 (11:15) 6/29/2022 06/29/2022
Misc
Resolved
06/29/2022
piers full of water pump out water for inspection
Electrical Service Inspection Passed 10/17/2022 10/17/2022 10/17/2022
Gas Service Inspection - Residential Failed 10/17/2022 10/17/2022 10/17/2022
Misc
Corrective Action Required
10/17/2022
provide minimum 10 psi at gas gauge and bond gas line
All Rough Inspection - Residential Not Ready 10/17/2022 10/17/2022 10/17/2022
Misc
Corrective Action Required
10/17/2022
inspection denied no city stamped plans on site
All Rough Inspection - Residential Failed 10/18/2022 10/18/2022 10/18/2022
Misc
Resolved
10/18/2022
inspection denied no city stamped plans on site
Misc
Corrective Action Required
10/18/2022
-anchor bolts to be tight see pfh, unfinished basement (Check throughout) -missing lib in garage -missing stud pack garage south wall -fire-block wall to ceiling space in dining area -tighten all nuts and bolts at beam in living room -fire blocking at fireplace -address over notched studs E and W basement wall -anchor bolts to be in the middle 1/3 of sill plate though out -fire block stud space to ceiling space rec room E wall -add blocking to plans under kitchen island to plans -fire block dead space at grinder pump -fire block into furr down above bed 4 window at beam -fire block bed 4 W wall to ceiling space -fireblock bed 4 closet to ceiling space
Gas Service Inspection - Residential Passed 10/24/2022 10/24/2022 10/24/2022
Misc
Resolved
10/24/2022
provide minimum 10 psi at gas gauge and bond gas line
All Rough Inspection - Residential Passed 10/24/2022 10/24/2022 10/24/2022
Misc
Resolved
10/24/2022
-anchor bolts to be tight see pfh, unfinished basement (Check throughout) -missing lib in garage -missing stud pack garage south wall -fire-block wall to ceiling space in dining area -tighten all nuts and bolts at beam in living room -fire blocking at fireplace -address over notched studs E and W basement wall -anchor bolts to be in the middle 1/3 of sill plate though out -fire block stud space to ceiling space rec room E wall -add blocking to plans under kitchen island to plans -fire block dead space at grinder pump -fire block into furr down above bed 4 window at beam -fire block bed 4 W wall to ceiling space -fireblock bed 4 closet to ceiling space
Driveway Inspection Passed 11/22/2022 11/22/2022
Misc
Informational
11/22/2022
On Tuesday, 11-22-2022. I performed and passed a driveway inspection for placement of concrete.
Sidewalk Inspection Passed 11/22/2022 11/22/2022
Misc
Informational
11/22/2022
On Tuesday, 11-22-2022. I performed and passed and inspection for sidewalk placement of concrete
Occupancy Inspection - Codes Residential Failed 2/10/2023 2/10/2023 02/10/2023
Misc
Corrective Action Required
02/10/2023
-outlets in kitchen will not re set -2 1/2” through bolts at deck post to beam connection -complete A/c install -check water meter at time of sod. (Ensure meter well flush height and meter depth in well 14”-18”) -label all non GFCI outlets in unfinished spaces
Occupancy Inspection - Codes Residential Ready for Temp CO 2/14/2023 2/14/2023 02/14/2023
Misc
Corrective Action Required
02/10/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of sod. (Ensure meter well flush height and meter depth in well 14”-18”)
Occupancy Inspection - Codes Residential Ready for Temp CO 3/13/2023 03/13/2023
Misc
Corrective Action Required
02/14/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of sod. (Ensure meter well flush height and meter depth in well 14”-18”)
Misc
Corrective Action Required
03/13/2023
TCO extention approved
Occupancy Inspection - Codes Residential Ready for Temp CO 4/12/2023 04/12/2023
Misc
Corrective Action Required
03/13/2023
Pay fee -sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of sod. (Ensure meter well flush height and meter depth in well 14”-18”)
Plot Plan Inspection Passed 05/01/2023
Erosion Control Inspection Residential Passed 05/01/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/01/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Mantain silt fence and clean debris from streets
Occupancy Inspection - Codes Residential Full C of O 5/1/2023 5/1/2023 05/01/2023
Misc
Resolved
05/01/2023
Pay fee -sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of sod. (Ensure meter well flush height and meter depth in well 14”-18”)
Documents & Images
Date Uploaded File Type Document Name
12/15/2021 WW34_001
12/16/2021 Approved Plans Approved Drawings
12/16/2021 Permit Codes Residential Plan Review
12/20/2021 Plot Plan Approved Plot Plan
12/20/2021 Permit Codes Residential Plan Review
12/20/2021 Permit DS Building Permit
12/20/2021 Receipt Receipt for transaction:2021-009402
01/18/2022 1705 SW 27 ST SOIL REPORT
01/18/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/02/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/18/2022 Letter INSPECTION SUMMARY
10/24/2022 Letter INSPECTION SUMMARY
10/24/2022 Letter INSPECTION SUMMARY
11/22/2022 Letter INSPECTION SUMMARY
11/22/2022 Letter INSPECTION SUMMARY
02/08/2023 Receipt Receipt for transaction:2023-000758
02/14/2023 Letter INSPECTION SUMMARY
02/14/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/14/2023 Receipt Receipt for transaction:2023-000866
03/06/2023 Extension Request Form (4)
03/13/2023 Certificate/License Codes Temporary Certificate of Occupancy
03/13/2023 Receipt Receipt for transaction:2023-001378
04/12/2023 Extension Request Form (1) (2) 1705
04/12/2023 Certificate/License Codes Temporary Certificate of Occupancy
04/12/2023 Receipt Receipt for transaction:2023-002042
05/01/2023 Letter INSPECTION SUMMARY
05/01/2023 Letter INSPECTION SUMMARY
05/01/2023 Letter Field Certificate of Occupancy
05/01/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home