Permit Application Status

PRRES20216389


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216389
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TOP DECK
12/15/2021
12/17/2021
05/17/2023
Locations
Contacts
BELLAH HOMES LLC, Address:P O BOX 346, Phone:(816) 697-2870  
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
Paul Miller, Address:P.O. Box 346, Phone:(816) 786-5050  
TROY@BELLAHHOMES.COM  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $480.00 $480.00 Paid 12/17/2021
Right of Way Permit Fee $85.00 $85.00 Paid 12/17/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/16/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 12/17/2021
Water Meter Fee $479.24 $479.24 Paid 12/17/2021
Valuation Fee New Single Family $1,345.21 $1,345.21 Paid 12/17/2021
New Longview Road and Bridge Escrow $1,077.12 $1,077.12 Paid 12/17/2021
Not Ready Inspection Fee $75.00 $75.00 Paid 04/12/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 04/12/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 2/9/2022 02/09/2022
Corrective Action Required
02/09/2022
Correct silt fence and clean street Post address
Underslab Plumbing Inspection - Residential Failed 2/9/2022 2/9/2022 02/09/2022
Miscellaneous Correction
Corrective Action Required
02/09/2022
Post address
Underslab Plumbing Inspection - Residential Passed 3/3/2022 3/3/2022 03/03/2022
Miscellaneous Correction
Resolved
03/03/2022
Post address
Sewer Service Inspection - R Passed 4/29/2022 (10:00) 4/29/2022 04/29/2022
Water Service Inspection - R Passed 5/2/2022 05/02/2022
Erosion Control Inspection Residential Passed 9/19/2022 09/19/2022
Footing Inspection - Residential Passed 9/30/2022 09/30/2022
Misc
Informational
09/30/2022
Footing Inspection done by third party Inspector, David Ainsworth
All Rough Inspection - Residential Failed 10/27/2022 10/27/2022 10/27/2022
Misc
Corrective Action Required
10/27/2022
- Fire block penetration garage vertical to horizontal joist both exterior walls power and opener sensor - Finish solid blocking of I-beam in garage - Security blocking for man door at garage - Address 3 1/2” hole not in middle third of rim joist bathroom at mud room - Mud room bathroom vent incomplete and should be 4” - Fire block top of chase left side of sliding door - Security blocking at sliding door - Gas piping incomplete at fire place, provide shut off valve and plumb - Secure CSST at fire place - Fire block fire place into attic space - Fire block penetration right of fire place - Blocking needed at all sheeting breaks on front walls - Make accessible for inspection front porch cover - Fire block top plate of double wall - Master and master bathroom - Master bathroom vent incomplete and should be 4” - Fire block penetration outdoor living room top plate right of window and Security blocking at door - Second floor bathroom vent incomplete and should be 4” - Protect wiring within 6’ from attic access - Fire block penetration top plate loft near bedroom 2 - Fire block double wall at loft from attic space - Address over notched hip rafter LVL bedroom 3 exterior wall - Address over notched hip rafters over cripple wall bedroom 2 - Plans call for 31/2” steel columns and 3” installed - Provide egress windows in basement - Solid block cantilever in basement - Flashing and trim window at front of house
Electrical Service Inspection Passed 10/27/2022 10/27/2022 10/27/2022
Gas Service Inspection - Residential Failed 10/27/2022 10/27/2022 10/27/2022
Misc
Corrective Action Required
10/27/2022
-Fire place incomplete - no shut off at fire place
All Rough Inspection - Residential Failed 11/2/2022 11/2/2022 11/02/2022
Misc
Corrective Action Required
10/27/2022
- Gas piping incomplete at fire place, provide shut off valve and plumb - Secure CSST at fire place - Make accessible for inspection front porch cover - Fire block top plate of double wall ( first to second floor) Master and master bathroom - Address over notched hip rafter LVL bedroom 3 exterior wall - Address over notched hip rafters over cripple wall bedroom 2 - Flashing and trim window at front of house - Install sliding door
All Rough Inspection - Residential Not Ready 11/8/2022 11/8/2022 11/08/2022
Misc
Corrective Action Required
11/02/2022
NO PLANS ON SITE NOT READY - Gas piping incomplete at fire place, provide shut off valve and plumb - Secure CSST at fire place - Make accessible for inspection front porch cover - Fire block top plate of double wall ( first to second floor) Master and master bathroom - Address over notched hip rafter LVL bedroom 3 exterior wall - Address over notched hip rafters over cripple wall bedroom 2 - Flashing and trim window at front of house - Install sliding door
Gas Service Inspection - Residential Passed 11/8/2022 11/8/2022 11/08/2022
Misc
Corrective Action Required
10/27/2022
-Fire place incomplete - no shut off at fire place
All Rough Inspection - Residential Passed 11/9/2022 11/9/2022 11/09/2022
Misc
Resolved
11/09/2022
Driveway Inspection Partial 2/2/2023 2/2/2023 02/02/2023
Misc
Informational
02/02/2023
2-2-23 DP Crew had SW formed, aggregate placed and compacted. Approved to pour
Sidewalk Inspection Partial 2/2/2023 2/2/2023 02/02/2023
Misc
Informational
02/02/2023
2-2-23 DP Crew had SW formed, aggregate placed and compacted. Approved to pour
Sidewalk Inspection Failed 2/9/2023 2/9/2023 02/27/2023
Misc
Informational
02/02/2023
2-2-23 DP Crew had SW formed, aggregate placed and compacted. Approved to pour 2-9-23 DP Crew poured SW and it is in compliance. passed
Miscellaneous Correction
Corrective Action Required
02/27/2023
2-27-23 DP. There are 3 panels that are not in ADA compliance. They are marked with an "X" the panels need to be replaced. Call back in for reinspection.
Sidewalk Inspection Partial 3/6/2023 3/6/2023 03/06/2023
Misc
Informational
02/27/2023
2-2-23 DP Crew had SW formed, aggregate placed and compacted. Approved to pour 2-9-23 DP Crew poured SW and it is in compliance. passed
Miscellaneous Correction
Corrective Action Required
02/27/2023
2-27-23 DP. There are 3 panels that are not in ADA compliance. They are marked with an "X" the panels need to be replaced. Call back in for reinspection.
Misc
Informational
03/06/2023
3-6-23 RH. Sidewalk is formed up and aggreagate is placed and compacted. Currently cross slope meets ADA specification. Approved to pour.
Sidewalk Inspection Passed 3/15/2023 3/15/2023 03/15/2023
Misc
Informational
03/06/2023
2-2-23 DP Crew had SW formed, aggregate placed and compacted. Approved to pour 2-9-23 DP Crew poured SW and it is in compliance. passed
Miscellaneous Correction
Corrective Action Required
03/06/2023
2-27-23 DP. There are 3 panels that are not in ADA compliance. They are marked with an "X" the panels need to be replaced. Call back in for reinspection.
Misc
Informational
03/06/2023
3-6-23 RH. Sidewalk is formed up and aggreagate is placed and compacted. Currently cross slope meets ADA specification. Approved to pour. 3-15-23 DP. Sidewalk was poured, is in compliance and passed.
Occupancy Inspection - Codes Residential Failed 4/6/2023 4/6/2023 04/06/2023
Misc
Corrective Action Required
04/06/2023
- pay fees - Provide splash pads - Final grading and sod - Seal exterior penetrations - Seal top of exterior light fixtures - Provide stairs for garage man door - Provide stairs for sliding door to patio - Missing outlet cover upstairs bathroom - Complete attic access - Support 3” DWV just inside basement door
Erosion Control Inspection Residential Failed 4/6/2023 04/06/2023
Misc
Corrective Action Required
04/06/2023
Restore erosion control at front of lot. No further inspections will be completed until erosion is compliant.
Occupancy Inspection - Codes Residential Ready for Temp CO 4/12/2023 4/12/2023 04/12/2023
Misc
Corrective Action Required
04/06/2023
- Provide splash pads - Final grading and sod - stairs for garage man door (Over 7 3/4" all risers ) TCO expires : May 12 2023
Erosion Control Inspection Residential Passed 5/17/2023 05/17/2023
Misc
Resolved
05/17/2023
Restore erosion control at front of lot. No further inspections will be completed until erosion is compliant.
Plot Plan Inspection Passed 5/17/2023 05/17/2023
Occupancy Inspection - Codes Residential Full C of O 5/12/2023 5/17/2023 05/17/2023
Misc
Corrective Action Required
04/12/2023
Documents & Images
Date Uploaded File Type Document Name
12/15/2021 Lot 115 Tax Application
12/15/2021 Lot 115 Residential Permit Application
12/16/2021 Approved Plans APPROVED PLANS
12/16/2021 Plot Plan APPROVED PLOT PLAN
12/17/2021 Permit Codes Residential Plan Review
12/17/2021 Permit DS Building Permit
12/17/2021 Receipt Receipt for transaction: 2021-009367
01/02/2022 3230 SW Pergola Park Dr LSMO Pergola Park Lot 115 Bellah P 2021-6389 3rd Party Footing Inspection
02/09/2022 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
09/19/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
11/08/2022 3230 sw pergola park dr_ Lot 115 Pergola Park - Inspection Letter for Hip Rafters(11-8-22)
11/08/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter INSPECTION SUMMARY
11/09/2022 Letter INSPECTION SUMMARY
02/02/2023 Letter INSPECTION SUMMARY
02/02/2023 Letter INSPECTION SUMMARY
02/09/2023 Letter INSPECTION SUMMARY
02/27/2023 Letter INSPECTION SUMMARY
03/06/2023 Letter INSPECTION SUMMARY
03/15/2023 Letter INSPECTION SUMMARY
04/06/2023 Letter INSPECTION SUMMARY
04/06/2023 Letter INSPECTION SUMMARY
04/06/2023 Letter INSPECTION SUMMARY
04/12/2023 Receipt Receipt for transaction:2023-002025
04/12/2023 Certificate/License Codes Temporary Certificate of Occupancy
04/12/2023 Receipt Receipt for transaction:2023-002029
05/17/2023 Letter Codes Final Certificate of Occupancy
05/17/2023 Letter Field Certificate of Occupancy
05/17/2023 Letter INSPECTION SUMMARY
05/17/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home