Permit Application Status

PRRES20216183


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216183
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
12/01/2021
12/02/2021
05/31/2022
07/31/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 12/02/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/02/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/02/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/02/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/02/2021
9110078-Valuation Fee New Single Family $1,127.60 $1,127.60 Paid 12/02/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/18/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/31/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/31/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/31/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/31/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/31/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/31/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 12/17/2021 (8:00) 12/17/2021 12/17/2021
Misc
Corrective Action Required
12/17/2021
-address excavated garage not per plans -DO NOT POUR Mitchell Schwarz 12/17/2021 9:12 AM
Footing Inspection - Residential Passed 12/17/2021 12/17/2021
Misc
Corrective Action Required
12/17/2021
Misc
Informational
12/17/2021
-PASSED PER MARK HARDING AND DAN HARPER
Underslab Plumbing Inspection - Residential Passed 1/18/2022 1/18/2022 01/18/2022
Erosion Control Inspection Residential Failed 2/11/2022 02/11/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/11/2022
DEFICIENT EROSION CONTROL INSTALLATION. -REPAIR DOWNED SILT FENCE
Sewer Service Inspection - R Passed 2/28/2022 02/28/2022
Water Service Inspection - R Passed 3/1/2022 (1:00) 3/1/2022 03/01/2022
Erosion Control Inspection Residential Failed 4/26/2022 04/26/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/26/2022
DEFICIENT EROSION CONTROL INSTALLATION. -REPAIR DOWNED SILT FENCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/26/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Repair downed silt fence Mitchell Schwarz 04/26/2022 2:56 PM
Piers/Caissons Inspection - Residential Passed 6/28/2022 (10:30) 6/28/2022 06/28/2022
Erosion Control Inspection Residential Failed 7/25/2022 07/25/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
07/25/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Repair downed silt fence Mitchell Schwarz 04/26/2022 2:56 PM
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/25/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 7/29/2022 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/29/2022
-anchor bolts to be within 12” of sill plate brakes -protect NM with in 6’ of attic access -complete return air in bed 2 -fireblock fridge wall to ceiling space -complete hood vent -snow blocking in dining room -fire block gathering room N wall, fireplace,furr downs. To ceiling space -missing lvl above gathering room -missing stud pack S owners suite wall -complete bath fan venting to exterior -anchor all steel columns in basement -steel columns to be of correct size -security blocking at basement door -address hole drilled closer than 2” to bottom of joist near basement door and bed room hall entry -address over notched joist above basement bath entry -fireblock vertically, horizontally every 10’ in basement -address holes drilled through joist above service panel and bed 3 drilled to close to edge and each other -fire block above service panel -anchor bolts in basement to be in the middle 1/3 of sill plate -repair holes cut in floor above bed 3 not being used for hvac -fire block into furr down in bed 4 -seal penetrations into furr down from bath in bed 4 -fire block into furr down bed 4 closet -fire block weather line wall into joist space -water shut off to to remain accessible -uncover beam splice for inspection s3.1 2 -plans call for 3 2x10 above S most basement windows -fireblock S most room -seal penetrations in joist space used for RA near S most basement room entry -will inspect deck at re inspection, deck not complete -provide gas pressure gauge for inspection with minimum 10psi
Electrical Service Inspection Passed 7/29/2022 7/29/2022 07/29/2022
Gas Service Inspection - Residential Failed 7/29/2022 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/29/2022
provide gas pressure gauge with min 10 psi for inspection
Erosion Control Inspection Residential Failed 7/29/2022 07/29/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/25/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/29/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. repair downed silt fence maintain overgrown vegetation
Gas Service Inspection - Residential Passed 8/23/2022 8/23/2022 08/23/2022
Misc
Resolved
08/23/2022
provide gas pressure gauge with min 10 psi for inspection
All Rough Inspection - Residential Failed 8/23/2022 8/23/2022 08/23/2022
Misc
Corrective Action Required
07/29/2022
-protect NM with in 6’ of attic access -snow blocking in dining room -provide lateral support for lvl above great room -address hole drilled closer than 2” to bottom of joist near basement door and bed room hall entry -address over notched joist above basement bath entry -fireblock vertically, horizontally every 10’ in basement seal gaps -address holes drilled through joist above service panel and bed 3 drilled to close to edge and each other -fire block into furr down bed 4 closet see beam and dead space to ceiling space -water shut off to to remain accessible -fireblock S most room -seal penetrations in joist space used for RA near S most basement room entry -2 (1/2”) through bolts at each deck post to beam connection -upload engineer letter to permit
All Rough Inspection - Residential Failed 8/26/2022 8/26/2022 08/26/2022
Misc
Corrective Action Required
08/23/2022
-protect NM with in 6’ of attic access -address hole drilled closer than 2” to bottom of joist near basement door and bed room hall entry -fireblock vertically, horizontally every 10’ in basement seal gaps -fire block into furr down bed 4 closet see beam and dead space to ceiling space -water shut off to to remain accessible -fireblock S most room
All Rough Inspection - Residential Passed 8/29/2022 8/29/2022 08/29/2022
Misc
Resolved
08/29/2022
-protect NM with in 6’ of attic access -address hole drilled closer than 2” to bottom of joist near basement door and bed room hall entry -fireblock vertically, horizontally every 10’ in basement seal gaps -fire block into furr down bed 4 closet see beam and dead space to ceiling space -water shut off to to remain accessible -fireblock S most room
Driveway Inspection Partial 9/15/2022 9/15/2022 09/15/2022
Misc
Informational
09/15/2022
9-15-22 RH. Driveway is formed up and aggregate is placed and compacted.
Driveway Inspection Passed 9/22/2022 9/22/2022 09/22/2022
Misc
Informational
09/15/2022
9-15-22 RH. Driveway is formed up and aggregate is placed and compacted. 9-22-22 RH. Driveway meets LS specification.
Erosion Control Inspection Residential Failed 11/21/2022 11/21/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
11/21/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/21/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. repair downed silt fence maintain overgrown vegetation
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/21/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 11/23/2022 11/23/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
11/23/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Informational
11/23/2022
Erosion control in compliance 11/23/22 Mitchell Schwarz
Plot Plan Inspection Passed 1/17/2023 01/17/2023
Occupancy Inspection - Codes Residential Failed 1/17/2023 1/17/2023 01/17/2023
Misc
Corrective Action Required
01/17/2023
EROSION CONTROL TO REMAIN IN COMPLIANCE UNTIL SOD IN PLACE NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE -sod -splash blocks and sump pump discharge to extend 36” from foundation -identified sewer tracer wire -lable all non GFCI protected outlets in unfinished spaces. -security screws at rear patio door
Occupancy Inspection - Codes Residential Ready for Temp CO 1/18/2023 1/18/2023 01/18/2023
Misc
Corrective Action Required
01/17/2023
EROSION CONTROL TO REMAIN IN COMPLIANCE UNTIL SOD IN PLACE NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE -sod -splash blocks and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Failed 2/17/2023 02/17/2023
Misc
Corrective Action Required
01/18/2023
EROSION CONTROL TO REMAIN IN COMPLIANCE UNTIL SOD IN PLACE NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE -sod -splash blocks and sump pump discharge to extend 36” from foundation
Erosion Control Inspection Residential Passed 5/1/2023 05/01/2023
Misc
Resolved
05/01/2023
Erosion control in compliance 11/23/22 Mitchell Schwarz
Occupancy Inspection - Codes Residential Failed 5/1/2023 5/1/2023 05/01/2023
Misc
Corrective Action Required
02/17/2023
pay all fees -sod address sod at NW corner -Address siding from grade at back of home
Occupancy Inspection - Codes Residential Failed 7/31/2023 7/31/2023 07/31/2023
Misc
Corrective Action Required
05/01/2023
pay all fees
Occupancy Inspection - Codes Residential Full C of O 07/31/2023
Misc
Resolved
07/31/2023
pay all fees
Documents & Images
Date Uploaded File Type Document Name
12/01/2021 0893_001
12/02/2021 Permit Codes Residential Plan Review
12/02/2021 Plot Plan APPROVED PLOT PLAN
12/02/2021 Permit Codes Residential Plan Review
12/02/2021 Permit DS Building Permit
12/02/2021 Receipt Receipt for transaction:2021-009062
12/17/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
02/03/2022 Approved Plans APPROVED PLANS
02/11/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/17/2022 Approved Plans APPROVED PLANS
04/26/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
08/23/2022 2022_08_08_2804 SW Hearthstone Pl_LSMO_City IDR Response_Sealed(1)
08/26/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter INSPECTION SUMMARY
09/22/2022 Letter INSPECTION SUMMARY
11/21/2022 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/18/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/18/2023 Receipt Receipt for transaction:2023-000307
02/17/2023 Letter INSPECTION SUMMARY
02/17/2023 Letter Codes 10 Day Letter
02/21/2023 Application Form Extension Request Form (1)
05/01/2023 Letter INSPECTION SUMMARY
05/01/2023 Letter INSPECTION SUMMARY
07/31/2023 Letter INSPECTION SUMMARY
07/31/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/31/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/31/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/31/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/31/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/31/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/31/2023 Receipt Receipt for transaction:2023-005926
07/31/2023 Letter Field Certificate of Occupancy
07/31/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home