Permit Application Status

PRRES20216146


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216146
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED BASEMENT. ROOF TRUSSES.
11/29/2021
12/06/2021
05/31/2022
09/15/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 12/06/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 12/06/2021
Water Meter Fee $479.24 $479.24 Paid 12/06/2021
Right of Way Permit Fee $85.00 $85.00 Paid 12/06/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/06/2021
Valuation Fee New Single Family $866.56 $866.56 Paid 12/06/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/17/2021 (9:30) 12/17/2021 12/17/2021
Underslab Plumbing Inspection - Residential Passed 1/19/2022 1/19/2022 01/19/2022
Sewer Service Inspection - R Passed 1/24/2022 (1:00) 1/24/2022 01/24/2022
Water Service Inspection - R Passed 1/25/2022 (1:00) 1/25/2022 01/25/2022
Gas Service Inspection - Residential Passed 6/1/2022 6/1/2022 06/01/2022
Electrical Service Inspection Passed 6/1/2022 6/1/2022 06/01/2022
All Rough Inspection - Residential Failed 6/1/2022 6/1/2022 06/01/2022
Misc
Corrective Action Required
06/01/2022
-address over notched stud SW garage wall -fireblock furr out wall in garage -seal all top plate penetrations N garage wall -address dryer vent length -missing nails in lib master closet -seal gaps in fire blocking in hvac chase master bath entry -missing hold down on truss between great room and master -nail cspf at rear dining room windows to plans. -missing hold downs on truss above dining -fire block furr out right of fridge -missing hold downs on gt truss above 2 closet both ends of truss -fire block furr down ends in basement -solid blocking under kitchen island to plans (one joist bay past) -bed 4 RA pass through in furr down -first block penetrations into furr down bed 4 -address over notched joist above bottom of stairs in basement -address access to unfinished space in basement furnace and future water heater blocking access
All Rough Inspection - Residential Failed 6/9/2022 6/9/2022 06/09/2022
Misc
Corrective Action Required
06/01/2022
-seal gaps in fire blocking in hvac chase master bath entry -fire block furr out right of fridge seal gaps -address over notched joist above bottom of stairs in basement (nail to ENGINEER SPECIFICATIONS)
All Rough Inspection - Residential Passed 6/13/2022 6/13/2022 06/13/2022
Misc
Resolved
06/13/2022
Driveway Inspection Passed 6/27/2022 6/27/2022 06/27/2022
Misc
Informational
06/27/2022
On Monday, 6-27-2022 I performed a driveway inspection and passed the inspection for placement of concrete.
Sidewalk Inspection Passed 6/27/2022 6/27/2022 06/27/2022
Misc
Informational
06/27/2022
On Monday, 6-27-2022. I performed and passed a sidewalk inspection for placement of concrete.
Erosion Control Inspection Residential Failed 9/1/2022 09/01/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/01/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 9/1/2022 9/1/2022 09/01/2022
Misc
Corrective Action Required
09/01/2022
-sod -splash blocks and sump pump discharge to extend 36” from foundation -address piers poured without inspection -submit as graded plot plan -check water meter at time of sod -attic access cover in garage -anchor steel column in basement -address broken flex duct next electrical panel and joist over board for this -guard rail at window well where required at rear of lot
Plot Plan Inspection Passed 9/2/2022 09/02/2022
Piers/Caissons Inspection - Residential Passed 9/15/2022 09/15/2022
Erosion Control Inspection Residential Passed 9/15/2022 09/15/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/15/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Full C of O 9/15/2022 9/15/2022 09/15/2022
Misc
Resolved
09/15/2022
-attic access cover in garage -anchor steel column in basement -address broken flex duct next electrical panel and joist over board for this -guard rail at window well where required at rear of lot
Documents & Images
Date Uploaded File Type Document Name
11/29/2021 H3 #74 - PERMIT APP
12/02/2021 Approved Plans APPROVED TRUSS PACKAGE
12/02/2021 Approved Plans APPROVED TRUSS LAYOUT
12/02/2021 Approved Plans APPROVED DRAWINGS
12/02/2021 Permit Codes Residential Plan Review
12/06/2021 Plot Plan APPROVED PLOT PLAN
12/06/2021 Permit Codes Residential Plan Review
12/06/2021 Permit DS Building Permit
12/06/2021 Receipt Receipt for transaction:2021-009120
12/17/2021 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/24/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
06/08/2022 74 Hawthorne Ridge Field Issue_
06/09/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 74 piers
09/01/2022 74 footing piers
09/01/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
09/15/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter Field Certificate of Occupancy
09/15/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home