Permit Application Status

PRRES20215858


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215858
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED DECK.
11/09/2021
11/16/2021
05/11/2022
08/22/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
JASONFW1@COMCAST.NET  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 11/16/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/16/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/16/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/16/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/16/2021
9110078-Valuation Fee New Single Family $1,136.10 $1,136.10 Paid 11/16/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/07/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/29/2021 (10:00) 11/29/2021 11/29/2021
Underslab Plumbing Inspection - Residential Passed 12/10/2021 12/10/2021 12/10/2021
Sewer Service Inspection - R Passed 12/20/2021 (11:30) 12/20/2021 12/20/2021
Water Service Inspection - R Passed 12/21/2021 12/21/2021
Erosion Control Inspection Residential Failed 1/21/2022 01/21/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/21/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 9:12 AM
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/21/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO INSPECTION(S) BEING PERFORMED.
Piers/Caissons Inspection - Residential Failed 4/13/2022 4/13/2022 04/13/2022
Misc
Corrective Action Required
04/13/2022
Address piers poured without inspection
Electrical Service Inspection Passed 4/13/2022 4/13/2022 04/13/2022
Gas Service Inspection - Residential Passed 4/13/2022 4/13/2022 04/13/2022
All Rough Inspection - Residential Failed 4/13/2022 4/13/2022 04/13/2022
Misc
Corrective Action Required
04/13/2022
-Address PFH strapping and remove covering to inspect nail pattern -provide attic access -address rafter to top plate connection. (Single car garage, bed 2) -seal holes in floor not being used -missing nails in hangers above kitchen and dining room area -address RA at S great room wall Above blocking -uncover covered patio for inspection -Back patio to dining area detail s3.2 10 -5 studs under lvl at master/great room per plans -complete master entry door framing -midway strap Dwv less than 2” in diameter see master -complete RA in master -no roof load above master bath per plans -fire block furr down above master shower -3 studs under lvl at shower per plan -strap top plate where lapped less than 24” master walk-in closet south wall -seal bottom plate penetration bed 2 bath -address ceiling height above bottom steps to basement -furr out and fire block for dwv in Rec room -fire block furr down for beam in basement Ne rec room -fire block furr down above bed 4 W wall and N wall -fire block to ceiling space SW corner bed 4 -fire block at top plate basement bath W wall -complete framing for mechanical room door
Erosion Control Inspection Residential Failed 4/27/2022 04/27/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
04/27/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 9:12 AM
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
04/27/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO INSPECTION(S) BEING PERFORMED.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/27/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Mitchell Schwarz 04/27/2022 1:41 PM
All Rough Inspection - Residential Failed 4/27/2022 4/27/2022 04/27/2022
Misc
Corrective Action Required
04/13/2022
-Address PFH strapping and remove covering to inspect nail pattern -address rafter to top plate connection. (Single car garage, bed 2) -missing nails in hangers above kitchen -uncover covered patio for inspection -Back patio to dining area detail s3.2 10 -fire block furr down above bed 4 W wall
Erosion Control Inspection Residential Not Ready 5/13/2023 05/13/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/27/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Mitchell Schwarz 04/27/2022 1:41 PM
Misc
Corrective Action Required
05/13/2022
*5/13/22 Erosion control still not in compliance. Fee assessed. Street cleanup required immediately
All Rough Inspection - Residential Passed 6/16/2022 6/16/2022 06/16/2022
Misc
Resolved
06/16/2022
Driveway Inspection Partial 8/11/2022 8/11/2022 08/11/2022
Misc
Informational
08/11/2022
8-11-22 RH. Driveway forms were up and aggregate was placed and compacted.
Driveway Inspection Passed 8/18/2022 8/18/2022 08/18/2022
Misc
Informational
08/11/2022
8-11-22 RH. Driveway forms were up and aggregate was placed and compacted. 8-18-22 RH. Driveway was poured and meets LS and ADA specification.
Piers/Caissons Inspection - Residential Passed 5/9/2023 05/09/2023
Misc
Resolved
05/09/2023
Address piers poured without inspection
Erosion Control Inspection Residential Passed 5/9/2023 05/09/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/09/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Mitchell Schwarz 04/27/2022 1:41 PM
Misc
Resolved
05/09/2023
*5/13/22 Erosion control still not in compliance. Fee assessed. Street cleanup required immediately
Occupancy Inspection - Codes Residential Failed 5/9/2023 5/9/2023 05/09/2023
Misc
Corrective Action Required
05/09/2023
-provide as graded plot plan -properly install spark ring above fireplace -provide provide gravel filter under water meter provide 6” of clearance underneath meter setter. Ensure 14”-18” from meter top to well lid ring.
Plot Plan Inspection Passed 08/22/2023
Occupancy Inspection - Codes Residential Full C of O 8/22/2023 8/22/2023 08/22/2023
Misc
Resolved
08/22/2023
-provide as graded plot plan -properly install spark ring above fireplace -provide provide gravel filter under water meter provide 6” of clearance underneath meter setter. Ensure 14”-18” from meter top to well lid ring.
Documents & Images
Date Uploaded File Type Document Name
11/09/2021 LOT 42 FINAL survey
11/11/2021 Application Form APPLICATION
11/11/2021 Letter EXCISE TAX FORM
11/12/2021 Approved Plans APPROVED DRAWINGS
11/12/2021 Permit Codes Residential Plan Review
11/16/2021 Plot Plan APPROVED PLOT PLAN
11/16/2021 Permit Codes Residential Plan Review
11/16/2021 Permit DS Building Permit
11/16/2021 Receipt Receipt for transaction:2021-008773
11/29/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
12/29/2021 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
06/14/2022 1700 SW 27th Street - Structural Letter (June 13, 2022)
06/16/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/18/2022 Letter INSPECTION SUMMARY
12/07/2022 1700 SW 27th St ROW
12/07/2022 Receipt Receipt for transaction:2022-009342
01/05/2023 Letter Codes 140 Day Letter
05/08/2023 1700 SW 27th St_ Pier Inspection
05/09/2023 Letter INSPECTION SUMMARY
05/09/2023 Letter Codes 180 Day Letter
05/09/2023 Letter INSPECTION SUMMARY
05/09/2023 Letter INSPECTION SUMMARY
05/09/2023 1700 SW 27th 180 day expired letter
05/09/2023 1700 SW 27th 180 day expired letter
08/01/2023 LOT 42 ASBUILT 1700 SW 27th St
08/04/2023 1700 Sw 27th Extension Request
08/22/2023 Letter INSPECTION SUMMARY
08/22/2023 Letter Field Certificate of Occupancy
08/22/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home