NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - UNFINISHED BASEMENT -
10/29/2021
11/09/2021
04/30/2022
05/11/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
SUPERIORREALESTATESERVICES@GMAIL.COM  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/09/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/09/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 11/09/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/09/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/09/2021
9110078-Valuation Fee New Single Family $1,343.69 $1,343.69 Paid 11/09/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/09/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/09/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/09/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/23/2021 (8:00) 11/23/2021 11/23/2021
Sewer Service Inspection - R Passed 12/15/2021 (1:00) 12/15/2021 12/15/2021
Underslab Plumbing Inspection - Residential Passed 12/17/2021 12/17/2021 12/17/2021
Water Service Inspection - R Passed 12/17/2021 (1:00) 12/17/2021 12/17/2021
Erosion Control Inspection Residential Failed 1/21/2022 01/21/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/21/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 9:19 AM
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/21/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Electrical Service Inspection Passed 4/27/2022 04/27/2022
Gas Service Inspection - Residential Passed 4/27/2022 4/27/2022 04/27/2022
All Rough Inspection - Residential Failed 4/27/2022 4/27/2022 04/27/2022
Misc
Corrective Action Required
04/27/2022
-install all doors and windows -address rafters landing on blocks -seal N garage wall into furr down missing places and penetrations -seal bottom plate penetration N garage wall -complete stairs at garage entry -block under cantilever in garage -provide attic access in garage -(3) 2x10 above garage entry/kitchen -seal hole in floor at kitchen island not being used -uncover covered rear patio for inspection of s3.2 10 at deck per plans and inspection of rear beam -3 studs under lvl per plans at entry/great room -front entry wall to be framed to plans -fix hole in floor at entry and bottom plate penetration -snow block at entry W wall -uncover covered front patio for inspection -complete front patio framing -strap top plate bed 4 N wall where lapped less than 24” -address over notched hip rafter in master -steel columns in basement to be of correct size and anchored -solid block under cantilever
All Rough Inspection - Residential Failed 5/4/2022 5/4/2022 05/04/2022
Misc
Corrective Action Required
04/27/2022
-install all doors and windows -address rafters landing on blocks -complete stairs at garage entry -uncover covered rear patio for inspection of s3.2 10 at deck per plans and inspection of rear beam -front entry wall to be framed to plans -uncover covered front patio for inspection -complete front patio framing -solid block under cantilever in basement
All Rough Inspection - Residential Failed 5/25/2022 5/25/2022 05/25/2022
Misc
Corrective Action Required
05/04/2022
-install front door -complete stairs at garage entry -front entry wall to be framed to plans (3king studs to plans) -complete front patio framing -Okay to insulate do not cover any items in need of inspections
All Rough Inspection - Residential Failed 6/2/2022 6/2/2022 06/02/2022
Misc
Corrective Action Required
05/25/2022
-install front door -Okay to insulate
Driveway Inspection Passed 9/6/2022 9/6/2022 09/06/2022
Misc
Informational
09/06/2022
On Tuesday, 9-06-2022 I performed and passed a driveway inspection for placement of concrete.
All Rough Inspection - Residential Passed 1/11/2023 01/11/2023
Misc
Corrective Action Required
06/02/2022
-install front door -Okay to insulate
Piers/Caissons Inspection - Residential Passed 1/11/2023 01/11/2023
Occupancy Inspection - Codes Residential Failed 1/11/2023 1/11/2023 01/11/2023
Misc
Corrective Action Required
01/11/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation -uncover water meter and bring to grade while maintaining 14”-18” from top of meter to lid -provide secondary locking device for rear slider -hand rail in garage to comply with code section r311.7.8.4
Occupancy Inspection - Codes Residential Ready for Temp CO 3/2/2023 03/02/2023
Misc
Corrective Action Required
01/11/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation -uncover water meter and bring to grade while maintaining 14”-18” from top of meter to lid
Plot Plan Inspection Passed 5/9/2023 05/09/2023
Erosion Control Inspection Residential Passed 5/9/2023 05/09/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
05/09/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 9:19 AM
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/09/2023
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Occupancy Inspection - Codes Residential Failed 5/9/2023 5/9/2023 05/09/2023
Misc
Resolved
05/09/2023
-sod -splash blocks and sump pump discharge to extend 36” from foundation -uncover water meter and bring to grade while maintaining 14”-18” from top of meter to lid
Misc
Corrective Action Required
05/09/2023
Home being occupied without certificate of occupancy. Pay all fees
Occupancy Inspection - Codes Residential Full C of O 05/11/2023
Misc
Resolved
05/11/2023
Home being occupied without certificate of occupancy. Pay all fees
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home