Permit Application Status

PRRES20215552


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215552
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
10/22/2021
10/25/2021
08/19/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 10/25/2021
Right of Way Permit Fee $85.00 $85.00 Paid 10/25/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/25/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 10/25/2021
Water Meter Fee $479.24 $479.24 Paid 10/25/2021
Valuation Fee New Single Family $928.91 $928.91 Paid 10/25/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 08/18/2022
3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 08/18/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/15/2021 12/15/2021
Misc
Informational
12/15/2021
3RD PARTY FOOTING BY DEREK PEREZ @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED CENTER OF WEST (REAR) GARAGE FOUNDATION WALL
Underslab Plumbing Inspection - Residential Passed 1/12/2022 1/12/2022 01/12/2022
Sewer Service Inspection - R Passed 1/27/2022 (10:30) 1/27/2022 01/27/2022
Water Service Inspection - R Passed 1/28/2022 (11:30) 1/28/2022 01/28/2022
Gas Service Inspection - Residential Passed 5/4/2022 5/4/2022 05/04/2022
Electrical Service Inspection Passed 5/4/2022 5/4/2022 05/04/2022
All Rough Inspection - Residential Not Ready 5/4/2022 5/4/2022 05/04/2022
Miscellaneous Correction
Corrective Action Required
05/04/2022
NO DOCUMENTS AT ALL, INSPECTION DENIED NO TRUSS PACKAGE ( CITY STAMPED) NO PLANS (CITY STAMPED)
Erosion Control Inspection Residential Failed 5/6/2022 05/06/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/06/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
All Rough Inspection - Residential Failed 5/6/2022 5/6/2022 05/06/2022
Miscellaneous Correction
Resolved
05/06/2022
NO DOCUMENTS AT ALL, INSPECTION DENIED NO TRUSS PACKAGE ( CITY STAMPED) NO PLANS (CITY STAMPED)
Miscellaneous Correction
Corrective Action Required
05/06/2022
Truss screws shall extend through double top plate Provide HUS26 hangers per truss layout bed 2 Seal fire blocking & upward penetration fireplace Strap top plate breaks within 24" garage near front door Engineer to address field modifications to truss M6 foyer Fire block dead space above refrigerator Seal upward penetrations outside bed 1 door Seal upward penetration bed 1 SW corner Solid fire-block chases filled with insulation Strap top plate & provide boca plate at dryer vent Fire block furr out at laundry room Provide nut & washer and tighten anchor bolts basement Anchor bolt shall be in middle third of width of plate Complete HVAC bed 4 Fire block soffit south wall Rex room Provide flashing above exterior horizontal trim Nail exterior wall sheathing per code
All Rough Inspection - Residential Failed 5/12/2022 5/12/2022 05/12/2022
Miscellaneous Correction
Corrective Action Required
05/06/2022
-Seal fire blocking & upward penetration fireplace-NOT DONE -Strap top plate breaks within 24" garage near front door -USE 24” STRAPS -Engineer to address field modifications to truss M6 foyer-NO CORRECTIONS PERFORMED ON DAMAGES-ALSO ADDRESS END CUT OFF AT FOYER -Fire block dead space above refrigerator-SEAL GAPS AND PENETRATIONS INTO ATTIC SPACE -Seal upward penetrations outside bed 1 door-NOT DONE -Solid fire-block chases filled with insulation-NOT DONE -Strap top plate & provide boca plate at dryer vent-PLATE TO PROTECT 2” BELOW TOP PLATE AND STRUCTURAL STRAP TO EXTEND MIN 6” EACH WAY OF BORE
All Rough Inspection - Residential Passed 5/17/2022 5/17/2022 05/17/2022
Miscellaneous Correction
Resolved
05/17/2022
Sidewalk Inspection Partial 06/22/2022
Misc
Informational
06/22/2022
Sidewalk was framed up with aggregate in and compacted. 6/14/22 ES
Driveway Inspection Partial 06/22/2022
Misc
Informational
06/22/2022
Sidewalk was framed up with aggregate in and compacted. 6/14/22 ES
Driveway Inspection Passed 06/22/2022
Misc
Informational
06/22/2022
Sidewalk was framed up with aggregate in and compacted. 6/14/22 ES Driveway meets LS and ADA specs. 6/22/22 ES
Sidewalk Inspection Passed 06/22/2022
Misc
Informational
06/22/2022
Sidewalk was framed up with aggregate in and compacted. 6/14/22 ES Sidewalk meets LS and ADA specs. 6/22/22 ES
Erosion Control Inspection Residential Passed 8/2/2022 08/02/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/02/2022
Plot Plan Inspection Passed 8/2/2022 08/02/2022
Piers/Caissons Inspection - Residential Passed 08/18/2022
Misc
Informational
08/18/2022
INSPECTION DONE BY THIRD PARTY.
Occupancy Inspection - Codes Residential Failed 8/18/2022 8/18/2022 08/18/2022
Misc
Corrective Action Required
08/18/2022
- Steps at garage more yhan 3/8" variance - saftey caps on A/C compressor required - Provide gutters and down spouts - splash blocks
Occupancy Inspection - Codes Residential Full C of O 8/19/2022 08/19/2022
Misc
Resolved
08/19/2022
Documents & Images
Date Uploaded File Type Document Name
10/22/2021 W2 #59 - Permit App
10/22/2021 Approved Plans approved plans
10/22/2021 Approved Plans APPROVED TRUSS LAYOUT
10/22/2021 Approved Plans APPROVED TRUSS PACKAGE
10/22/2021 Plot Plan APPROVED PLOT PLAN
10/25/2021 Permit Codes Residential Plan Review
10/25/2021 Permit DS Building Permit
10/25/2021 Receipt Receipt for transaction:2021-008206
12/15/2021 59 Woodside Ridge-FTNG
12/15/2021 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/06/2022 image
05/06/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter INSPECTION SUMMARY
05/10/2022 2935533 M6 REP 05102022
05/12/2022 Letter INSPECTION SUMMARY
05/16/2022 2935533 M6 REP#2 05132022
05/17/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
08/01/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/18/2022 Receipt Receipt for transaction:2022-006800
08/18/2022 Letter INSPECTION SUMMARY
08/18/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter Field Certificate of Occupancy
08/19/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home