Permit Application Status

PRRES20215425


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215425
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - UNCOVERED DECK
10/18/2021
10/28/2021
04/17/2022
06/07/2022
Locations
Contacts
ELEVATE DESIGN & BUILD LLC, Address:350 SW LONGVIEW BLVD, Phone:(816) 622-8826  
Elevate Design + Build , Address:350 Longview Blvd.   
SARA@ELEVATEDESIGNBUILDKC.COM  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 10/28/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/28/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/28/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/28/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/28/2021
9110078-Valuation Fee New Single Family $835.04 $835.04 Paid 10/28/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/01/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 12/8/2021 12/08/2021
Misc
Corrective Action Required
12/08/2021
-provide frost footing per plans for garage. -provide dead mans per plan
Footing Inspection - Residential Passed 12/15/2021 12/15/2021
Misc
Resolved
12/15/2021
-provide frost footing per plans for garage. -provide dead mans per plan
Informational
12/15/2021
3rd party inspection ufer ground center back side of garage wall
Sewer Service Inspection - R Passed 12/21/2021 12/21/2021
Water Service Inspection - R Partial 12/21/2021 12/21/2021
Misc
Informational
12/21/2021
Water Service Inspection - R Passed 12/22/2021 (10:45) 12/22/2021 12/22/2021
Misc
Informational
12/21/2021
Underslab Plumbing Inspection - Residential Failed 12/28/2021 12/28/2021 12/28/2021
Misc
Corrective Action Required
12/28/2021
-inspection denied due to lack of erosion control.
Erosion Control Inspection Residential Failed 12/28/2021 12/28/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/28/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. IF EROSION CONTROL IS NOT IN PLACE STOP WORK WILL BE ISSUED
Erosion Control Inspection Residential Partial 12/30/2021 12/30/2021
DCM3 ESC REQUIRED 2 DAY
Resolved
12/30/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. IF EROSION CONTROL IS NOT IN PLACE STOP WORK WILL BE ISSUED
Underslab Plumbing Inspection - Residential Passed 12/30/2021 12/30/2021 12/30/2021
Misc
Resolved
12/30/2021
-inspection denied due to lack of erosion control.
Erosion Control Inspection Residential Failed 02/10/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/10/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Gas Service Inspection - Residential Passed 2/16/2022 2/16/2022 02/16/2022
Electrical Service Inspection Passed 2/16/2022 2/16/2022 02/16/2022
All Rough Inspection - Residential Failed 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/16/2022
-address cspf and PFH in garage plans state double car garage cspf and PFH on single -all anchor bolts to be in the middle 1/3 of bottom plate garage and basement -support ridge both ends and joints above single car bay -all attic accesses require 30” clearance -nail all rafter to ceiling joist to rafters -support all dwv 2” in diameter or less at midway point -seal floor penetrations at kitchen island -land NM in living room ceiling to box -Seal penetration 2 penetration in master bath floor not used for dwv -provide proper slope for dwv above master bath -provide CS-PF per plans at living room back windows -provide CS-PF per plans at rec room back windows -seal penetration into furr down basement left hallway entry -fire blocking vertically to horizontally ever 10’ in basement (see bedroom 4) -fire block all furr downs in basement bed 4 and bed 3 window wall -address return air bed 4 (blocked off) -plans call for dbl 2x10 hip in master bed -address over notched rafters above bed 2 closet -complete bath vent in basement bath -secure pen in basement bath stud bay -address return air in bed 3 blocked off -seal top plate penetrations bed 3 entry -address furr down where smoke is mounted (not secured) -fire block furr down left of bed 3 window -solid block underneath lvl point load to I-beam below (duct will need to be moved)
All Rough Inspection - Residential Failed 3/1/2022 3/1/2022 03/01/2022
Misc
Corrective Action Required
02/16/2022
-address cspf and PFH in garage plans state double car garage cspf and PFH on single -seal floor penetrations at kitchen island -Seal penetration 2 penetration in master bath floor not used for dwv -provide CS-PF per plans at living room back windows -provide CS-PF per plans at rec room back windows -seal penetration into furr down basement left hallway entry -fire blocking vertically to horizontally ever 10’ in basement (see bedroom 4) -fire block all furr downs in basement bed 4 and bed 3 window wall -plans call for dbl 2x10 hip in master bed -address over notched rafters above bed 2 -secure pex in basement bath stud bay - return air in bed 3 and 4 need panning in soffits -fire block furr down left of bed 3 window -solid block underneath lvl point load to I-beam below (duct will need to be moved) Okay to insulate DO NOT COVER ANY ITEMS STILL NEEDING INSPECTION
Erosion Control Inspection Residential Failed 3/1/2022 3/1/2022 03/01/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
03/01/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/01/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. PROVIDE GRAEL FILTER
All Rough Inspection - Residential Passed 3/14/2022 3/14/2022 03/14/2022
Misc
Resolved
03/14/2022
-address cspf and PFH in garage plans state double car garage cspf and PFH on single -seal floor penetrations at kitchen island -Seal penetration 2 penetration in master bath floor not used for dwv -provide CS-PF per plans at living room back windows -provide CS-PF per plans at rec room back windows -seal penetration into furr down basement left hallway entry -fire blocking vertically to horizontally ever 10’ in basement (see bedroom 4) -fire block all furr downs in basement bed 4 and bed 3 window wall -plans call for dbl 2x10 hip in master bed -address over notched rafters above bed 2 -secure pex in basement bath stud bay - return air in bed 3 and 4 need panning in soffits -fire block furr down left of bed 3 window -solid block underneath lvl point load to I-beam below (duct will need to be moved) Okay to insulate DO NOT COVER ANY ITEMS STILL NEEDING INSPECTION
Sidewalk Inspection Failed 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/25/2022
Sidewalk has several soft spots that need to be dug out and recompacted. West end of sidewalk did not have aggregate in place at all. Marked bad areas with paint. 3/25/22 ES
Driveway Inspection Failed 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/25/2022
Driveway has soft/wet spots that need to be dug out and recompacted. 3/25/22 ES
Driveway Inspection Partial 3/28/2022 3/28/2022 03/28/2022
Misc
Corrective Action Required
03/25/2022
Driveway has soft/wet spots that need to be dug out and recompacted. 3/25/22 ES
Misc
Informational
03/28/2022
Driveway was framed up with aggregate in and compacted. 3/28/22 ES
Sidewalk Inspection Partial 3/28/2022 3/28/2022 03/28/2022
Misc
Corrective Action Required
03/25/2022
Sidewalk has several soft spots that need to be dug out and recompacted. West end of sidewalk did not have aggregate in place at all. Marked bad areas with paint. 3/25/22 ES
Misc
Informational
03/28/2022
Sidewalk was framed up with aggregate in and compacted. 3/28/22 ES
Sidewalk Inspection Failed 4/8/2022 4/8/2022 04/14/2022
Misc
Corrective Action Required
03/28/2022
Sidewalk has several soft spots that need to be dug out and recompacted. West end of sidewalk did not have aggregate in place at all. Marked bad areas with paint. 3/25/22 ES
Misc
Informational
03/28/2022
Sidewalk was framed up with aggregate in and compacted. 3/28/22 ES
Misc
Corrective Action Required
04/14/2022
Sidewalk is out of ADA tolerance on west end and also is set back too far across whole lot. Sidewalk setback is 5’ from curb and sidewalk is set at 6’ behind curb. Sidewalk will need to be removed and replaced within tolerance and at proper setback. 4/14/22 ES
Driveway Inspection Passed 4/8/2022 4/8/2022 04/14/2022
Misc
Corrective Action Required
03/28/2022
Driveway has soft/wet spots that need to be dug out and recompacted. 3/25/22 ES
Misc
Informational
03/28/2022
Driveway was framed up with aggregate in and compacted. 3/28/22 ES
Misc
Informational
04/14/2022
Driveway meets LS and Ada specs. 4/14/22 ES
Sidewalk Inspection Partial 4/27/2022 04/27/2022
Misc
Informational
04/27/2022
On 4.27.2022 I performed a sidewalk inspection and passed the subgrade to pour concrete.
Sidewalk Inspection Passed 4/29/2022 4/29/2022 05/10/2022
Misc
Corrective Action Required
04/14/2022
Sidewalk has several soft spots that need to be dug out and recompacted. West end of sidewalk did not have aggregate in place at all. Marked bad areas with paint. 3/25/22 ES
Misc
Informational
04/14/2022
Sidewalk was framed up with aggregate in and compacted. 3/28/22 ES
Misc
Corrective Action Required
04/14/2022
Sidewalk is out of ADA tolerance on west end and also is set back too far across whole lot. Sidewalk setback is 5’ from curb and sidewalk is set at 6’ behind curb. Sidewalk will need to be removed and replaced within tolerance and at proper setback. 4/14/22 ES
Misc
Informational
05/10/2022
Sidewalk was poured with proper setback and within LS and ADA specs. 5/10/22 ES
Occupancy Inspection - Codes Residential Not Ready 5/11/2022 5/11/2022 05/11/2022
Misc
Corrective Action Required
05/11/2022
-inspection denied no Premises Identification Mitchell Schwarz 05/11/2022 10:59 AM
Piers/Caissons Inspection - Residential Passed 5/25/2022 5/25/2022 05/25/2022
Misc
Informational
05/25/2022
Third party inspection performed
Plot Plan Inspection Passed 5/25/2022 05/25/2022
Occupancy Inspection - Codes Residential Failed 5/25/2022 5/25/2022 05/25/2022
Misc
Resolved
05/25/2022
-inspection denied no Premises Identification Mitchell Schwarz 05/11/2022 10:59 AM
Misc
Corrective Action Required
05/25/2022
-Obtain lawn irrigation permit -GFCI protection required at laundry -spark rings as required at kitchen outlets -open neutral at outlet under kitchen sink -outlet required at kitchen island to code -security screws at back doors -spark ring required above kitchen fire place -outlet in down stairs bath not working -lable breaker panel for inspection make sure all breakers requiring a lock out have one -secure A/c whip with in 12” of disconnect -tamper resistant caps at a/c unit -seal top of meter can, A/c disconnect and all other exterior penetrations
Occupancy Inspection - Codes Residential Full C of O 6/7/2022 6/7/2022 06/07/2022
Misc
Resolved
06/07/2022
-Obtain lawn irrigation permit -GFCI protection required at laundry -spark rings as required at kitchen outlets -open neutral at outlet under kitchen sink -outlet required at kitchen island to code -security screws at back doors -spark ring required above kitchen fire place -outlet in down stairs bath not working -lable breaker panel for inspection make sure all breakers requiring a lock out have one -secure A/c whip with in 12” of disconnect -tamper resistant caps at a/c unit -seal top of meter can, A/c disconnect and all other exterior penetrations
Documents & Images
Date Uploaded File Type Document Name
10/18/2021 License_Tax_Application
10/18/2021 Residental permit application
10/19/2021 Permit Codes Residential Plan Review
10/28/2021 Approved Plans approved plans
10/28/2021 Approved Plans APPROVED PLOT PLAN
10/28/2021 Permit Codes Residential Plan Review
10/28/2021 Permit DS Building Permit
10/28/2021 Receipt Receipt for transaction:2021-008324
12/08/2021 Letter INSPECTION SUMMARY
12/14/2021 41 Hook Farms FTNG-21-12-10
12/15/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/30/2021 Letter INSPECTION SUMMARY
12/30/2021 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/22/2022 Approved Plans APPROVED PLANS
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/10/2022 2031 SW Wheatfield Ct_Framing Evaluation Report_3-10-22
03/14/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
04/11/2022 Final_2022_03_28_DPier_LSMO_Pat Cochran Concrete
04/11/2022 Final_2022_03_28_DPier_LSMO_Pat Cochran Concrete
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
05/25/2022 Letter INSPECTION SUMMARY
06/01/2022 Receipt Receipt for transaction:2022-004136
06/07/2022 Letter Field Certificate of Occupancy
06/07/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home