Summary
PRRES20215418
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES.
10/18/2021
10/26/2021
11/23/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 10/26/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/26/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/26/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/26/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/26/2021
9110078-Valuation Fee New Single Family $1,049.06 $1,049.06 Paid 10/26/2021
8331504-EFHB Middle Big Creek, Full $401.76 $401.76 Paid 10/26/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/11/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/11/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/11/2022 1/11/2022 01/11/2022
Misc
Informational
01/11/2022
APPROVED PER BRADLEY HUXOL 11/10/21
Underslab Plumbing Inspection - Residential Passed 1/11/2022 1/11/2022 01/11/2022
Sewer Service Inspection - R Passed 1/13/2022 (10:30) 1/13/2022 01/13/2022
Water Service Inspection - R Passed 1/14/2022 (1:30) 1/14/2022 01/14/2022
Electrical Service Inspection Passed 6/6/2022 6/6/2022 06/06/2022
Gas Service Inspection - Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
06/06/2022
GAS LINE BOND REQUIRED
All Rough Inspection - Residential Failed 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
06/06/2022
-nail sheathing garage PFH per plans -address top plate corner lap connection required per code at NW corner garage exterior wall -seal low volt floor penetration at garage entry deadspace -seal all top plate penetrations - see laundry -min 24” lap between dbl top plate breaks - see garage wall -provide stud shoes at exterior studs bored for DWV master bath vanity -provide bocca protection plates bottom plate pex master shower -provide bocca protection plate at pex bottom plate fridge -seal gas line floor penetration at fireplace -secure gas line fireplace -address top plate corner lap connection front entry wall -min (2) nails each stud/plate LIB straps -CS-PF exterior bracing at great room windows per plans, nail exterior sheathing per design see plans/IRC R602.10.6.4 -dbl girder truss at front bed #3 bearing on blocks above top plate, provide proper bearing and attachment for uplift resistance -provide all truss hangers per plans -have engineer address damaged gable truss front bed#3 -solid block all sheathing breaks -gas line bond required
Gas Service Inspection - Residential Failed 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/06/2022
GAS LINE BOND REQUIRED
All Rough Inspection - Residential Not Ready 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/06/2022
**INSPECTION DENIED, NOT READY FOR INSPECTION -nail sheathing garage PFH per plans -address top plate corner lap connection required per code at NW corner garage exterior wall -seal low volt floor penetration at garage entry deadspace -seal all top plate penetrations - see laundry -min 24” lap between dbl top plate breaks - see garage wall -provide stud shoes at exterior studs bored for DWV master bath vanity -provide bocca protection plates bottom plate pex master shower -provide bocca protection plate at pex bottom plate fridge -seal gas line floor penetration at fireplace -secure gas line fireplace -address top plate corner lap connection front entry wall -min (2) nails each stud/plate LIB straps -CS-PF exterior bracing at great room windows per plans, nail exterior sheathing per design see plans/IRC R602.10.6.4 -dbl girder truss at front bed #3 bearing on blocks above top plate, provide proper bearing and attachment for uplift resistance -provide all truss hangers per plans -have engineer address damaged gable truss front bed#3 -solid block all sheathing breaks -gas line bond required
All Rough Inspection - Residential Not Ready 6/22/2022 6/22/2022 06/22/2022
Misc
Corrective Action Required
06/17/2022
NOT READY -address top plate corner lap connection required per code at NW corner garage exterior wall -seal low volt floor penetration at garage entry deadspace -seal all top plate penetrations - see laundry -seal gas line floor penetration at fireplace -min (2) nails each stud/plate LIB straps, tighten up loose x bracing -dbl girder truss at front bed #3 bearing on blocks above top plate, provide proper bearing and attachment for uplift resistance -provide all truss hangers per plans -have engineer address damaged gable truss bed#3
Gas Service Inspection - Residential Passed 6/22/2022 6/22/2022 06/22/2022
Misc
Resolved
06/22/2022
GAS LINE BOND REQUIRED
All Rough Inspection - Residential Passed 7/1/2022 7/1/2022 07/01/2022
Misc
Resolved
07/01/2022
Driveway Inspection Partial 8/9/2022 8/9/2022 08/09/2022
Misc
Informational
08/09/2022
8.9.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Partial 8/9/2022 8/9/2022 08/09/2022
Misc
Informational
08/09/2022
8.9.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 8/15/2022 (1:00) 8/15/2022 08/18/2022
Misc
Informational
08/09/2022
8.9.2022 I performed a driveway inspection and pass the subgrade to pour concrete 8.18.2022. Driveway appears to be in compliance
Sidewalk Inspection Passed 8/15/2022 (1:00) 8/15/2022 08/25/2022
Misc
Informational
08/09/2022
8.9.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete 8/19/2022 Sidewalk appears to be compliant
Occupancy Inspection - Codes Residential Failed 11/10/2022 11/10/2022 11/10/2022
Misc
Corrective Action Required
11/10/2022
-resolve outstanding inspection fees -remove old silt fence, construction debris and trash at rear of lot -provide handrail at rear patio stairs -provide gravel base at water meter -cap and label future vent at basement -provide AFCI protection at kitchen circuits -AC max overcurrent protection listed 30 amps
Plot Plan Inspection Passed 11/10/2022 11/10/2022 11/10/2022
Erosion Control Inspection Residential Passed 11/10/2022 11/10/2022 11/10/2022
Occupancy Inspection - Codes Residential Full C of O 11/23/2022 11/23/2022 11/23/2022
Misc
Resolved
11/23/2022
Documents & Images
Date Uploaded File Type Document Name
10/18/2021 RR #89 - PERMIT APP
10/20/2021 Approved Plans APPROVED DRAWINGS
10/20/2021 Approved Plans APPROVED TRUSS LAYOUT
10/20/2021 Approved Plans APPROVED TRUSS PACKAGE
10/20/2021 Plot Plan APPROVED PLOT PLAN
10/20/2021 Permit Codes Residential Plan Review
10/26/2021 Permit DS Building Permit
10/26/2021 Receipt Receipt for transaction:2021-008246
01/10/2022 89 Reserve at Stoney Creek FTNG
01/10/2022 89 Reserve at Stoney Creek FDTN
01/11/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/28/2022 89 Reserve at Stoney Creek Letter
06/28/2022 Letter APPROVED TRUSS LETTER
07/01/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/10/2022 Letter INSPECTION SUMMARY
11/11/2022 Receipt Receipt for transaction:2022-008872
11/23/2022 Letter Field Certificate of Occupancy
11/23/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home