Permit Application Status

PRRES20215333


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215333
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 01/24/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 04/04/2023 12:00 AM by username 'Mitchell Schwarz'.
10/12/2021
10/27/2021
04/18/2022
04/11/2023
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
Jennifer Pestka, Address:p o box 6423  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $450.00 $450.00 Paid 10/27/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/27/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/27/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/27/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/27/2021
9110078-Valuation Fee New Single Family $1,091.29 $1,091.29 Paid 10/27/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 07/27/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/03/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/03/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/4/2021 (8:00) 11/4/2021 11/04/2021
Underslab Plumbing Inspection - Residential Passed 1/11/2022 1/11/2022 01/11/2022
Sewer Service Inspection - R Passed 3/17/2022 (10:00) 3/17/2022 03/17/2022
Water Service Inspection - R Passed 3/17/2022 (3:30) 3/17/2022 03/17/2022
Piers/Caissons Inspection - Residential Passed 4/15/2022 04/15/2022
Erosion Control Inspection Residential Failed 4/15/2022 04/15/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/15/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Electrical Service Inspection Failed 7/13/2022 7/13/2022 07/13/2022
Misc
Corrective Action Required
07/13/2022
connect ufer ground to middle grounded bus bar.
Gas Service Inspection - Residential Failed 7/13/2022 7/13/2022 07/13/2022
Misc
Corrective Action Required
07/13/2022
provide minimum 10psi at pressure gauge for inspection.
Erosion Control Inspection Residential Failed 7/13/2022 07/13/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
07/13/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/13/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. maintain vegetation
All Rough Inspection - Residential Not Ready 7/13/2022 7/13/2022 07/13/2022
Misc
Corrective Action Required
07/13/2022
-garage portal frame missing straps and nailing from top plate to header -anchor bolts to be within 12” of plate breaks -missing studs garage E wall -furr down in garage for hvac -furr out walls for hvac -address cut double joist in garage -no fireblock has been done in home -connect ufer ground to middle grounded bus bar -provide minimum 10psi at gas gauge for inspection -HOUSE NOT READY FOR INSPECTION LIST SUBJECT TO CHANGE COMPLETE ALL ITEMS BEFORE REINSPECTION
Electrical Service Inspection Passed 7/21/2022 7/21/2022 07/21/2022
Misc
Resolved
07/21/2022
connect ufer ground to middle grounded bus bar.
Gas Service Inspection - Residential Passed 7/21/2022 7/21/2022 07/21/2022
Misc
Resolved
07/21/2022
provide minimum 10psi at pressure gauge for inspection.
All Rough Inspection - Residential Failed 7/22/2022 7/22/2022 07/22/2022
Misc
Corrective Action Required
07/13/2022
-missing nails in hanger above foyer -fire block foyer into furr down -complete and fireblock furr out wall in laundry -seal top plate penetration in laundry
All Rough Inspection - Residential Not Ready 7/27/2022 7/27/2022 07/27/2022
Misc
Corrective Action Required
07/22/2022
-missing nails in hanger above foyer -fire block foyer into furr down -complete and fireblock top furr out wall in laundry -seal top plate penetration in laundry
All Rough Inspection - Residential Passed 7/28/2022 7/28/2022 07/28/2022
Misc
Resolved
07/28/2022
-missing nails in hanger above foyer -fire block foyer into furr down -complete and fireblock top furr out wall in laundry -seal top plate penetration in laundry
Driveway Inspection Not Ready 9/21/2022 9/21/2022 09/21/2022
Misc
Informational
09/21/2022
9-21-22 RH. Driveway aggregate was not compacted.
Driveway Inspection Partial 9/28/2022 9/28/2022 09/28/2022
Misc
Informational
09/21/2022
9-21-22 RH. Driveway aggregate was not compacted. 9-28-22 RH. Driveway is formed up and aggregate is placed and compacted.
Driveway Inspection Passed 10/5/2022 10/5/2022 10/05/2022
Misc
Informational
09/28/2022
9-21-22 RH. Driveway aggregate was not compacted. 9-28-22 RH. Driveway is formed up and aggregate is placed and compacted. 10-5-22 RH. Driveway meets LS Specification.
Erosion Control Inspection Residential Failed 10/26/2022 10/26/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/26/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. maintain vegetation
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/26/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 10/26/2022 1:54 PM
Erosion Control Inspection Residential Failed - Stop Work 1/24/2023 01/24/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/26/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 10/26/2022 1:54 PM
Misc
Corrective Action Required
01/24/2023
erosion control not in compliance stop work issued
Driveway Inspection Passed 4/4/2023 04/04/2023
Misc
Informational
10/05/2022
9-21-22 RH. Driveway aggregate was not compacted. 9-28-22 RH. Driveway is formed up and aggregate is placed and compacted. 10-5-22 RH. Driveway meets LS Specification.
Erosion Control Inspection Residential Passed 4/3/2023 4/4/2023 04/04/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
04/04/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 10/26/2022 1:54 PM
Misc
Resolved
04/04/2023
erosion control not in compliance stop work issued
Plot Plan Inspection Passed 4/4/2023 04/04/2023
Occupancy Inspection - Codes Residential Failed 4/4/2023 4/4/2023 04/04/2023
Misc
Corrective Action Required
04/04/2023
-master bath fan not working in toilet room.
Occupancy Inspection - Codes Residential Full C of O 4/11/2023 4/11/2023 04/11/2023
Misc
Resolved
04/11/2023
-master bath fan not working in toilet room.
Documents & Images
Date Uploaded File Type Document Name
10/12/2021 2023 SW Farm Field Ln - Permit Application
10/12/2021 2023 SW Farm Field Ln - Tax Application
10/13/2021 Permit Codes Residential Plan Review
10/14/2021 Plot Plan APPROVED PLOT PLAN
10/20/2021 Permit Codes Residential Plan Review
10/20/2021 Approved Plans approved plans
10/20/2021 Permit Codes Residential Plan Review
10/27/2021 Permit DS Building Permit
10/27/2021 Receipt Receipt for transaction:2021-008305
11/04/2021 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/27/2022 Receipt Receipt for transaction:2022-006141
07/27/2022 Letter INSPECTION SUMMARY
07/27/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
09/21/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
10/05/2022 Letter INSPECTION SUMMARY
10/26/2022 Letter INSPECTION SUMMARY
01/24/2023 Letter Stop Work Order
04/03/2023 Receipt Receipt for transaction:2023-001833
04/04/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter INSPECTION SUMMARY
04/04/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter Field Certificate of Occupancy
04/11/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home