Permit Application Status

PRRES20215181


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215181
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. COVERED DECK. STOP WORK ORDER generated on 05/23/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 06/27/2022 12:00 AM by username 'Diana Johnson'.
10/04/2021
10/11/2021
04/04/2022
02/01/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
JASONFW1@COMCAST.NET  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 10/11/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/11/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/11/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/11/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/11/2021
9110078-Valuation Fee New Single Family $1,342.00 $1,342.00 Paid 10/11/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/31/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/31/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/01/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/01/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/01/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/22/2021 10/22/2021 10/22/2021
Underslab Plumbing Inspection - Residential Passed 11/10/2021 11/10/2021 11/10/2021
Sewer Service Inspection - R Passed 12/2/2021 (1:00) 12/2/2021 12/02/2021
Water Service Inspection - R Passed 12/3/2021 (3:00) 12/3/2021 12/03/2021
Gas Service Inspection - Residential Passed 4/28/2022 4/28/2022 04/28/2022
Electrical Service Inspection Passed 4/28/2022 4/28/2022 04/28/2022
All Rough Inspection - Residential Failed 4/28/2022 4/28/2022 04/28/2022
Misc
Corrective Action Required
04/28/2022
-missing nuts on anchors in garage -install all windows and doors -missing hangers above single car garage -address missing studs at rear garage wall -furr out and fire block for dwv in garage -complete stairs at garage and fire block -seal top plate penetration at hvac chase -seal penetrations in floor not used for gas -security blocking at rear door -uncover covered back patio for inspection of rear most beam -uncover S3.2 10 at back patio for inspection -fire block above fire place -front entry wall to be framed to plans -uncover covered front porch for inspection -block cantilever flex room -complete plumbing at tub for bath 2 -complete bath fans at master -address rafters landing on non load bearing wall. Master bath/bed 2 bath -strap top plate where lapped less than 24” master/master bath -seal floor penetration in jack and Jill bath -complete bath fan in jack and Jill bath -anchor all steel columns in basement
All Rough Inspection - Residential Failed 5/16/2022 5/16/2022 05/16/2022
Misc
Corrective Action Required
04/28/2022
-missing nuts on anchors in garage -install all windows and doors -complete stairs at garage and fire block -seal penetrations in floor not used for gas -complete bath fans at master -address rafters landing on non load bearing wall. Master bath/bed 2 bath -strap top plate where lapped less than 24” master/master bath -complete bath fan in jack and Jill bath
Erosion Control Inspection Residential Failed 5/18/2022 05/18/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Not Ready 5/18/2022 5/18/2022 05/18/2022
Misc
Corrective Action Required
05/16/2022
-missing nuts on anchors in garage (could not inspect) -install all windows and doors -complete stairs at garage and fire block -complete bath fans at master -complete bath fan in jack and Jill bath
Erosion Control Inspection Residential Failed - Stop Work 5/23/2022 05/23/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
05/23/2022
Erosion control still not in compliance 5/23/22
Driveway Inspection Partial 6/27/2022 6/27/2022 06/27/2022
Misc
Informational
06/27/2022
On 6.27.2022 Monday I performed a driveway inspection and pass the sub-grade to pour concrete.
All Rough Inspection - Residential Passed 8/30/2022 8/30/2022 08/30/2022
Misc
Corrective Action Required
05/18/2022
-missing nuts on anchors in garage (could not inspect) -install all windows and doors -complete stairs at garage and fire block -complete bath fans at master -complete bath fan in jack and Jill bath
Piers/Caissons Inspection - Residential Passed 8/30/2022 08/30/2022
Plot Plan Inspection Passed 8/30/2022 08/30/2022
Occupancy Inspection - Codes Residential Failed 8/30/2022 8/30/2022 08/30/2022
Misc
Corrective Action Required
08/30/2022
-address pending driveway inspection -address broken up back patio -pay all fees -obtain lawn irrigation permit -address to be properly illuminated -security screws at garage rear door -stairs at back patio to code -water anti syphon device with set screw sheered off -lock out for hot water heater -splash block and sump pump discharge to extend 36” from foundation -check water meter at time of sod -check siding from grade at time of sod
Occupancy Inspection - Codes Residential Ready for Temp CO 8/31/2022 8/31/2022 08/31/2022
Misc
Corrective Action Required
08/30/2022
-address pending driveway inspection -address broken up back patio -pay all fees -obtain lawn irrigation permit -address to be properly illuminated -splash block and sump pump discharge to extend 36” from foundation -check water meter at time of sod -check siding from grade at time of sod
Occupancy Inspection - Codes Residential Temporary C of O 9/1/2022 09/01/2022
Misc
Corrective Action Required
08/31/2022
-address pending driveway inspection -address broken up back patio -pay all fees -obtain lawn irrigation permit -address to be properly illuminated -splash block and sump pump discharge to extend 36” from foundation -check water meter at time of sod -check siding from grade at time of sod
Driveway Inspection Passed 1/24/2023 1/24/2023 01/24/2023
Misc
Informational
06/27/2022
On 6.27.2022 Monday I performed a driveway inspection and pass the sub-grade to pour concrete. 1-24-23 PS driveway meets LS Specifications
Occupancy Inspection - Codes Residential Failed 1/26/2023 1/26/2023 01/26/2023
Misc
Corrective Action Required
09/01/2022
-pay all fees -address to be properly illuminated
Erosion Control Inspection Residential Passed 02/01/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/01/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
02/01/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Resolved
02/01/2023
Erosion control still not in compliance 5/23/22
Occupancy Inspection - Codes Residential Full C of O 2/1/2023 02/01/2023
Misc
Resolved
02/01/2023
-pay all fees -address to be properly illuminated
Documents & Images
Date Uploaded File Type Document Name
10/05/2021 2034 Hook Farms Dr City Application
10/06/2021 Approved Plans APPROVED DRAWINGS
10/06/2021 Permit Codes Residential Plan Review
10/08/2021 Plot Plan APPROVED PLOT PLAN
10/08/2021 Permit Codes Residential Plan Review
10/11/2021 Permit DS Building Permit
10/11/2021 Receipt Receipt for transaction:2021-007889
10/11/2021 Approved Plans APPROVED DRAWINGS
10/22/2021 Letter INSPECTION SUMMARY
11/10/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
04/21/2022 Final_2022_04_12_DPier_LSMO_Pat Cochran Concrete
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/18/2022 2034 Hook Farms Dr - Structural Letter(1)
05/18/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter Stop Work Order
06/27/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
08/30/2022 Letter INSPECTION SUMMARY
08/31/2022 Receipt Receipt for transaction:2022-007172
09/01/2022 Letter Codes Temporary Certificate of Occupancy
01/19/2023 Letter Codes 140 Day Letter
01/24/2023 Letter INSPECTION SUMMARY
01/26/2023 Letter INSPECTION SUMMARY
02/01/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/01/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/01/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/01/2023 Receipt Receipt for transaction:2023-000618
02/01/2023 Letter INSPECTION SUMMARY
02/01/2023 Letter Field Certificate of Occupancy
02/01/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home