Permit Application Status

PRRES20215041


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215041
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED BASEMENT. COVERED DECK. ROOF TRUSSES.
09/27/2021
10/04/2021
03/27/2022
08/26/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 10/04/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 10/04/2021
Water Meter Fee $479.24 $479.24 Paid 10/04/2021
Right of Way Permit Fee $85.00 $85.00 Paid 10/04/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/04/2021
Valuation Fee New Single Family $1,074.90 $1,074.90 Paid 10/04/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 08/26/2022
Not Ready Inspection Fee $50.00 $50.00 Paid 08/26/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 10/19/2021 10/19/2021
Footing Inspection - Residential Passed 10/19/2021 10/19/2021 10/19/2021
Misc
Informational
10/19/2021
APPROVED PER BRADLEY HUXOL 10/14/21
Underslab Plumbing Inspection - Residential Not Ready 10/21/2021 10/21/2021 10/21/2021
Misc
Corrective Action Required
10/21/2021
Plumbing not present
Sewer Service Inspection - R Passed 10/25/2021 (9:30) 10/25/2021 10/25/2021
Water Service Inspection - R Passed 10/26/2021 (8:30) 10/26/2021 10/26/2021
Underslab Plumbing Inspection - Residential Passed 11/12/2021 11/12/2021 11/11/2021
Misc
Resolved
11/11/2021
Plumbing not present
Gas Service Inspection - Residential Passed 4/26/2022 4/26/2022 04/26/2022
Electrical Service Inspection Passed 4/26/2022 4/26/2022 04/26/2022
All Rough Inspection - Residential Failed 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/26/2022
-add studs at gt bearing points in garage S wall -seal top plate penetration laundry -cspf at bed one -address cut trusses above bed one -missing truss hold downs in bed one -seal top plate penetrations in bed one -fire block dead space bed one entry -fire block above fireplace -secure gas line at fireplace -remove scab pieces at back great room wall -check hold downs throughout to be properly installed -fire block dead space at stairs -fireblock furr out wall at kitchen -fire block dead space in this area -fireblock and fix framing at fridge -seal top plate penetration at bed 2/garage -plans call for 3 2x10 in basement -solid blocking where noted under kitchen island in basement -seal penetrations in fire blocking basement S wall -anchor bolts in the middle third of sill plate in basement -fire block west basement wall at beam -vertical to horizontal fire blocking every 10’ in basement -stud spacing more than 24” bed 3 -seal top plate penetration bed 4 entry -fire block above bed 4 window -
All Rough Inspection - Residential Failed 4/29/2022 4/29/2022 04/29/2022
Misc
Corrective Action Required
04/26/2022
-fireblock furr out wall at kitchen -fire block dead space in this area -fireblock and fix framing at fridge -plans call for 3 2x10 in basement -solid blocking where noted under kitchen island in basement extend one joist bay past -seal penetrations in fire blocking basement S wall -anchor bolts in the middle third of sill plate in basement -vertical to horizontal fire blocking every 10’ in basement seal gaps -stud spacing more than 24” bed 3
All Rough Inspection - Residential Failed 5/6/2022 5/6/2022 05/06/2022
Misc
Corrective Action Required
04/29/2022
-plans call for 3 2x10 in basement -stud spacing more than 24” bed 3
All Rough Inspection - Residential Passed 5/12/2022 5/12/2022 05/12/2022
Misc
Resolved
05/12/2022
-plans call for 3 2x10 in basement -stud spacing more than 24” bed 3
Piers/Caissons Inspection - Residential Passed 6/6/2022 06/06/2022
Misc
Informational
06/06/2022
addressed in thirrd party footing inspection
Occupancy Inspection - Codes Residential Not Ready 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
06/06/2022
inspection denied not ready -drive way and side walk not completed and poured -no permanent premises identification -open junction boxes at front of home right and left of garage
Occupancy Inspection - Codes Residential Failed 8/1/2022 8/1/2022 08/01/2022
Misc
Resolved
08/01/2022
inspection denied not ready -drive way and side walk not completed and poured -no permanent premises identification -open junction boxes at front of home right and left of garage
Misc
Corrective Action Required
08/01/2022
-pay all fees -open junction box’s right and let of garage doors -sod (submit as graded plot plan before sod) -splash blocks and sump pump discharge to extend 36” from foundation -illuminate address -check water meter at time of final grade and sod -guard rail at front stoop where required -spindle at stairwell missing -spark right above fire place -install shower glass -stairs in garage to be within 3/8” difference -guard rail at deck not to have spacing more that 4” at spindles -deck stairs greater than 7 3/4” -(2) 1/2” through bolts at deck post to beam connections -tamper caps at A/c unit -seal all exterior penetrations
Occupancy Inspection - Codes Residential Failed 8/22/2022 8/22/2022 08/22/2022
Misc
Corrective Action Required
08/01/2022
-pay all fees -submit as graded plot plan -guard rail at front stoop where required 30” from grade 36” out -stairs in garage to be within 3/8” difference -secondary locking device at rear slider -deck stairs greater than 7 3/4”
Plot Plan Inspection Passed 8/23/2022 08/23/2022
Occupancy Inspection - Codes Residential Full C of O 8/26/2022 8/26/2022 08/26/2022
Misc
Resolved
08/26/2022
-pay all fees -guard rail at front stoop where required 30” from grade 36” out -deck stairs greater than 7 3/4”
Documents & Images
Date Uploaded File Type Document Name
09/27/2021 H4 #134 - PERMIT APPLICATION
09/28/2021 Approved Plans APPROVED DRAWINGS
09/28/2021 Approved Plans APPROVED TRUSS LAYOUT
09/28/2021 Approved Plans APPROVED TRUSS PACKAGE
09/28/2021 Permit Codes Residential Plan Review
10/04/2021 Plot Plan APPROVED PLOT PLAN
10/04/2021 Permit Codes Residential Plan Review
10/04/2021 Permit DS Building Permit
10/04/2021 Receipt Receipt for transaction:2021-007736
10/18/2021 134 Hawthorne Ridge Subgrade
10/18/2021 134 Hawthorne Ridge FTNG
10/19/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/25/2021 Letter INSPECTION SUMMARY
10/26/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
03/31/2022 Letter Codes 140 Day Letter
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/28/2022 134 Scab Truss
04/29/2022 Letter INSPECTION SUMMARY
05/06/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
08/22/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
08/26/2022 Receipt Receipt for transaction:2022-007031
08/26/2022 Letter Codes Final Certificate of Occupancy
08/26/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home