Permit Application Status

PRRES20215037


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215037
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED AND UNCOVERED DECK - ROOF TRUSSES - TILE ROOF
09/27/2021
09/28/2021
12/13/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 09/28/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/28/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 09/28/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 09/28/2021
9110078-Valuation Fee New Single Family $1,065.76 $1,065.76 Paid 09/28/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/28/2021
9110078-Additional Permit Fee $152.07 $152.07 Paid 08/16/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/15/2021 (9:30) 11/15/2021 11/15/2021
Sewer Service Inspection - R Passed 11/30/2021 (1:45) 11/30/2021 11/30/2021
Water Service Inspection - R Passed 12/1/2021 (9:15) 12/1/2021 12/01/2021
Underslab Plumbing Inspection - Residential Passed 12/1/2021 12/1/2021 12/01/2021
Erosion Control Inspection Residential Failed 4/27/2022 04/27/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/27/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
All Rough Inspection - Residential Failed 7/7/2022 7/7/2022 07/07/2022
Misc
Corrective Action Required
07/07/2022
**CLEAN DEBRIS OFF THE STREET. PROVIDE EROSION CONTROL AT DOWNWARD SLOPE SIDEOF LOT -Anchor garage PFH wall sill plates -Anchor garage sill plate within 12” of break -Nail together the girder truss above garage -Protect wiring within six ft of attic access -Protect dryer duct at garage wall top plate -Complete wall and secure electrical boxes in laundry; Fb as required -Tie down trusses to garage/dwelling wall -Fb opening to soffit above master bathroom sinks -Protect SE cable at master bathroom bottom wall plate -Nail corner studs per code at rear dining -Provide wall receptacle spacing per code at rear great room wall -Protect gas csst line at fireplace entry -Provide support devices for CJ trusses per truss layout throughout -Provide full support for A10 girder truss at both ends; tie down this girder at front bedroom -Strap top plates where lapped less than two ft at bathroom 2 -Provide a receptacle at foyer guardrail -Tie down trusses to entry wall -Secure switch box at entry -Complete wall at stair/garage; Fb as required -Cannot notch joist at middle third of joist (below bathroom 2) -Provide min 1” clearance from wiring to b-vent **OK TO INSULATE
Electrical Service Inspection Passed 7/7/2022 7/7/2022 07/07/2022
Gas Service Inspection - Residential Failed 7/7/2022 7/7/2022 07/07/2022
Misc
Corrective Action Required
07/07/2022
Provide min ten psi pressure
All Rough Inspection - Residential Failed 7/28/2022 7/28/2022 07/28/2022
Misc
Corrective Action Required
07/07/2022
**PROVIDE ACCESS/LADDER FOR ENTRY AT FRONT OR GARAGE TO MUD -Complete wall and secure electrical boxes in laundry; Fb as required -Tie down trusses to garage/dwelling wall -Fb opening to soffit above master bathroom sinks -Protect SE cable at master bathroom bottom wall plate -Nail corner studs per code at rear dining -Provide wall receptacle spacing per code at rear great room wall -Protect gas csst line at fireplace entry -Provide support devices for CJ trusses per truss layout throughout -Provide full support for A10 girder truss at both ends; tie down this girder at front bedroom -Strap top plates where lapped less than two ft at bathroom 2 -Provide a receptacle at foyer guardrail -Tie down trusses to entry wall -Secure switch box at entry -Complete wall at stair/garage; Fb as required -Cannot notch joist at middle third of joist (below bathroom 2) -Provide min 1” clearance from wiring to b-vent **OK TO INSULATE
All Rough Inspection - Residential Passed 7/29/2022 7/29/2022 07/29/2022
Misc
Resolved
07/29/2022
Piers/Caissons Inspection - Residential Failed 8/19/2022 (8:30) 8/19/2022 08/19/2022
Misc
Corrective Action Required
08/19/2022
south most pier to be 36" deep in undisturbed soil
Piers/Caissons Inspection - Residential Failed 8/22/2022 (11:00) 8/22/2022 08/22/2022
Misc
Corrective Action Required
08/19/2022
address 3 other piers poured without inspection south most pier okay to pour
Driveway Inspection Partial 8/24/2022 8/24/2022 08/25/2022
Misc
Informational
08/25/2022
Driveway was framed up with aggregate in and compacted. 8/24/22 ES
Driveway Inspection Passed 9/2/2022 9/2/2022 09/12/2022
Misc
Informational
08/25/2022
Driveway was framed up with aggregate in and compacted. 8/24/22 ES Driveway meets LS specs. 9/12/22 ES
All Rough Inspection - Residential Failed 9/21/2022 09/21/2022
Misc
Corrective Action Required
09/21/2022
- complete ductwork at basement bathroom vent - Strap DWV in basement bathroom - Air admittance valve is too low at basement bar sink. I would like to see this tied into vent system but not mandatory .
Gas Service Inspection - Residential Passed 9/26/2022 09/26/2022
Misc
Resolved
09/26/2022
All Rough Inspection - Residential Passed 9/26/2022 09/26/2022
Misc
Resolved
09/26/2022
Erosion Control Inspection Residential Failed 10/24/2022 10/24/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/27/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/24/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Passed 12/01/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/01/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/01/2022
Piers/Caissons Inspection - Residential Passed 12/1/2022 12/01/2022
Misc
Informational
12/01/2022
3 other piers poured at time of footing inspected by third party. south most pier okay to pour
Plot Plan Inspection Passed 12/1/2022 12/01/2022
Occupancy Inspection - Codes Residential Failed 12/1/2022 12/1/2022 12/01/2022
Misc
Corrective Action Required
12/01/2022
- GFCI protect outlet in laundry near garage entry - Anchor steel column unfinished basement south side - Remove gauge from gas line at furnace - Install water heater - Connect water to humidifier - Provide anti siphon device at basement spigot - Handrail at garage stairs to be 34-38” above nose of tread - Provide gutters - Secure A/C whip - Seal exterior penetrations ie. gas line under deck
Occupancy Inspection - Codes Residential Full C of O 12/13/2022 12/13/2022 12/13/2022
Misc
Resolved
12/13/2022
Documents & Images
Date Uploaded File Type Document Name
09/27/2021 W1 #32 - Permit App
09/27/2021 Approved Plans approved plans
09/27/2021 Approved Plans APPROVED TRUSS LAYOUT
09/27/2021 Approved Plans APPROVED TRUSS PACKAGE
09/27/2021 Plot Plan APPROVED PLOT PLAN
09/28/2021 Permit Codes Residential Plan Review
09/28/2021 Permit DS Building Permit
09/28/2021 Receipt Receipt for transaction:2021-007622
11/15/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter INSPECTION SUMMARY
04/20/2022 Letter Codes 140 Day Letter
04/27/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/25/2022 32 Woodside Ridge Field Letter
07/27/2022 32 Woodside Ridge Field Letter rev
07/28/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
08/15/2022 W1 #32 - Scope of Work Statement Application
08/16/2022 Approved Plans APPROVED PLANS
08/16/2022 Approved Plans approved plot plan
08/16/2022 Receipt Receipt for transaction:2022-006718
08/19/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/21/2022 Letter INSPECTION SUMMARY
09/26/2022 Letter INSPECTION SUMMARY
09/26/2022 Letter INSPECTION SUMMARY
10/24/2022 Letter INSPECTION SUMMARY
11/14/2022 Piers
11/30/2022 32 Woodside Ridge Deck Piers
12/01/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/13/2022 Letter Codes Final Certificate of Occupancy
12/13/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home