Summary
PRRES20214994
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK SUSPENDED STOOP STOP WORK ORDER generated on 11/10/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 11/18/2021 12:00 AM by username 'Patrick Schonfeldt'.
09/23/2021
10/15/2021
04/12/2022
09/16/2022
Locations
Contacts
ROBERT A WASHAM CONSTRUCTION INC, Address:2058 NW SOUTH OUTER RD, Phone:(816) 224-5583  
Lindsay Cutler, Address:2058 NW South Outer Rd, Phone:(816) 224-5583  
MARK VANBEBBER , Address:2058 NW SOUTH OUTER RD , Phone:(816) 363-9470  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
MARKV@ROBWASHAMHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/15/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/15/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 10/15/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/15/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/15/2021
9110078-Valuation Fee New Single Family $1,382.95 $1,382.95 Paid 10/15/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/26/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/29/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed - Stop Work 11/10/2021 11/10/2021 11/10/2021
Misc
Corrective Action Required
11/10/2021
EROSION CONTROL REQUIRED ON LOT, FOOTING POURED ON 11/8/21, THIRD PARTY REPORT INDICATES THAT EROSION CONTROL IS IN COMPLIANCE, ADDRESS EROSION CONTROL IMMEDIATELY, SPOILS PILES AGAINST CURB LINE- STOP WORK ISSUED
Erosion Control Inspection Residential Failed 11/10/2021 11/10/2021 11/10/2021
Misc
Corrective Action Required
11/10/2021
EROSION CONTROL REQUIRED ON LOT, FOOTING POURED ON 11/8/21, THIRD PARTY REPORT INDICATES THAT EROSION CONTROL IS IN COMPLIANCE, ADDRESS EROSION CONTROL IMMEDIATELY, SPOILS PILES AGAINST CURB LINE- STOP WORK ISSUED
Footing Inspection - Residential Passed 11/18/2021 11/18/2021 11/18/2021
Misc
Resolved
11/18/2021
EROSION CONTROL REQUIRED ON LOT, FOOTING POURED ON 11/8/21, THIRD PARTY REPORT INDICATES THAT EROSION CONTROL IS IN COMPLIANCE, ADDRESS EROSION CONTROL IMMEDIATELY, SPOILS PILES AGAINST CURB LINE- STOP WORK ISSUED
Erosion Control Inspection Residential Partial 11/18/2021 11/18/2021 11/18/2021
Misc
Resolved
11/18/2021
Underslab Plumbing Inspection - Residential Passed 12/10/2021 12/10/2021 12/10/2021
Sewer Service Inspection - R Passed 12/14/2021 (8:30) 12/14/2021 12/14/2021
Water Service Inspection - R Partial 12/14/2021 12/14/2021
Water Service Inspection - R Passed 12/15/2021 (8:45) 12/15/2021 12/15/2021
Erosion Control Inspection Residential Failed 1/21/2022 01/21/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/21/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/21/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Failed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/12/2022
-Nail siding to sill plates per code -Anchor garage sill plates within 12” of breaks -Complete fur out laundry wall and Fb from joist space -Provide double 2x10 header support for rear dining ridge beam. Engineer to look at strap reinforcement of non-continuous stud wall for compliance with code performance criteria -Support rear dining ridge beam to (2)2x10 -Provide 16” lvl under bedroom 3 exterior closet wall -Plan shows J4 (16” lvl) at walkway, but 16” lvl is cut to 9.5”. Have engineer address this -If cabinet with countertop is installed on both sides of fireplace, provide wall receptacle compliance per 210.52. Receptacles inside cabinet does not count -Secure fireplace to framing -Engineer to address reinforcement of master bedroom gable wall. Just additional comment: I think the lvl ridge beam above master bedroom spans a little too far. You have a double 9.5" lvl under the master toilet wall, but it's not being used -Install smoke alarm near top of master bedroom vaulted ceiling -Complete framing of duct/b-vent chase and Fb this space from joist space and roof space -Complete framing at bedroom 5 shower and Fb space from roof -Protect wiring at bedroom 5 closet bottom wall plate -Support ridge above bedroom 5 -Install radon vent roof flashing above bedroom 5 -Brace ends of lvl roof beam from rotation -Attic access at bedroom 3 closet must have min 30” headroom clearance -Protect plumbing in shared bathroom -Bedroom 4 gable wall studs. It continuous from floor to ceiling -Bond gas piping -Header off cut joist below duct/b-vent chase -Seal penetrations of return air space under master bathroom -Notched joist below master bath water closet -Provide basement wall vertical fire blocking no more than then ft apart -Basement sill plate anchor must be within middle 1/3 of plate; provide min 2 anchors per short plate **DO NOT INSULATE
Electrical Service Inspection Passed 4/12/2022 4/12/2022 04/12/2022
Gas Service Inspection - Residential Passed 4/12/2022 4/12/2022 04/12/2022
All Rough Inspection - Residential Not Ready 5/4/2022 5/4/2022 05/04/2022
Misc
Corrective Action Required
04/12/2022
Inspection denied -no city stamped plans on site. -provide engineer letters as needed -Nail siding to sill plates per code -Anchor garage sill plates within 12” of breaks -Complete fur out laundry wall and Fb from joist space -Provide double 2x10 header support for rear dining ridge beam. Engineer to look at strap reinforcement of non-continuous stud wall for compliance with code performance criteria -Support rear dining ridge beam to (2)2x10 -Provide 16” lvl under bedroom 3 exterior closet wall -Plan shows J4 (16” lvl) at walkway, but 16” lvl is cut to 9.5”. Have engineer address this -If cabinet with countertop is installed on both sides of fireplace, provide wall receptacle compliance per 210.52. Receptacles inside cabinet does not count -Secure fireplace to framing -Engineer to address reinforcement of master bedroom gable wall. Just additional comment: I think the lvl ridge beam above master bedroom spans a little too far. You have a double 9.5" lvl under the master toilet wall, but it's not being used -Install smoke alarm near top of master bedroom vaulted ceiling -Complete framing of duct/b-vent chase and Fb this space from joist space and roof space -Complete framing at bedroom 5 shower and Fb space from roof -Protect wiring at bedroom 5 closet bottom wall plate -Support ridge above bedroom 5 -Install radon vent roof flashing above bedroom 5 -Brace ends of lvl roof beam from rotation -Attic access at bedroom 3 closet must have min 30” headroom clearance -Protect plumbing in shared bathroom -Bedroom 4 gable wall studs. It continuous from floor to ceiling -Bond gas piping -Header off cut joist below duct/b-vent chase -Seal penetrations of return air space under master bathroom -Notched joist below master bath water closet -Provide basement wall vertical fire blocking no more than then ft apart -Basement sill plate anchor must be within middle 1/3 of plate; provide min 2 anchors per short plate **DO NOT INSULATE
All Rough Inspection - Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
05/04/2022
-The ridge beam above master bedroom was not framed per engineer letter. Submit new revised letter -Brace ends of lvl roof beam from rotation -Seal penetrations of return air space under master bathroom -Notched joist below master bath water closet -Provide basement wall vertical fire blocking no more than then ft apart -Basement sill plate anchor must be within middle 1/3 of plate; provide min 2 anchors per short plate; tighten anchor nuts **OK TO INSULATE
All Rough Inspection - Residential Passed 5/11/2022 5/11/2022 05/11/2022
Misc
Resolved
05/11/2022
-The ridge beam above -Seal penetrations of return air space under master bathroom -Notched joist below master bath water closet -Provide basement wall vertical fire blocking no more than then ft apart -Basement sill plate anchor must be within middle 1/3 of plate; provide min 2 anchors per short plate; tighten anchor nuts **OK TO INSULATE
Erosion Control Inspection Residential Failed 5/13/2022 05/13/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/21/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/21/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO ANY INSPECTION(S) BEING PERFORMED.
Driveway Inspection Passed 7/6/2022 07/06/2022
Misc
Informational
07/06/2022
On Wednesday, 7-06-2022 I performed and passed the subgrade for driveway placement for concrete.
Sidewalk Inspection Passed 7/6/2022 07/06/2022
Misc
Informational
07/06/2022
On Wednesday, 7-06-2022. I performed and passed a sidewalk inspection for concrete placement.
Occupancy Inspection - Codes Residential Failed 8/24/2022 8/24/2022 08/24/2022
Misc
Corrective Action Required
08/24/2022
inspection denied no erosion control in place
Piers/Caissons Inspection - Residential Passed 8/25/2022 08/25/2022
Misc
Informational
08/25/2022
Third party
Plot Plan Inspection Passed 8/25/2022 08/25/2022
Occupancy Inspection - Codes Residential Failed 8/25/2022 8/25/2022 08/25/2022
Misc
Resolved
08/25/2022
inspection denied no erosion control in place
Misc
Corrective Action Required
08/25/2022
-address pending sidewalk inspection -pay all fees -obtain lawn irrigation permit -sod -splash blocks and sump pump discharge to extend 36” from foundation -guard rail at front stoop where 30” from ground 36” out -provide attic access cover -security screws at basement exterior doors -water hammer resistors at basement laundry -Sheetrock under in basement -(2) 1/2” through bolts at each deck post to beam connections -check siding from grade at time of sod
Sidewalk Inspection Passed 8/29/2022 8/29/2022 08/29/2022
Misc
Informational
08/29/2022
On Monday 8-29-2022 I performed a visual inspection for the existing sidewalk and find it passes city specifications
Occupancy Inspection - Codes Residential Ready for Temp CO 8/29/2022 8/29/2022 08/29/2022
Misc
Corrective Action Required
08/25/2022
-pay all fees -obtain lawn irrigation permit -siding from grade at rear of lot
Occupancy Inspection - Codes Residential Temporary C of O 8/29/2022 08/29/2022
Misc
Corrective Action Required
08/29/2022
-pay all fees -obtain lawn irrigation permit -siding from grade at rear of lot
Erosion Control Inspection Residential Passed 9/16/2022 09/16/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
09/16/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
09/16/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO ANY INSPECTION(S) BEING PERFORMED.
Occupancy Inspection - Codes Residential Full C of O 9/16/2022 9/16/2022 09/16/2022
Misc
Resolved
09/16/2022
-pay all fees -obtain lawn irrigation permit -siding from grade at rear of lot
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home