Permit Application Status

PRRES20214367


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214367
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. COVERED DECK. FINISHED BASEMENT.
08/23/2021
11/08/2021
02/23/2022
10/12/2022
Locations
Contacts
SPELLERBERG ENTERPRISES LLC, Address:613 NE VIEWPARK DR, Phone:(816) 550-5535  
Billy Spellerberg, Address:613 ne viewpark dr  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
NEW HEIGHTS ELECTRIC LLC, Address:P O BOX 163, Phone:(816) 625-9504  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
SPELLERBERGENTERPRISES@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 11/08/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/08/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/08/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/08/2021
9110078-Valuation Fee New Single Family $1,480.75 $1,480.75 Paid 11/08/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/08/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 11/11/2021 (11:00) 11/11/2021 11/11/2021
Misc
Corrective Action Required
11/11/2021
Not ready for inspection at 11, no rebar in footing yet, recall when complete
Footing Inspection - Residential Failed 11/11/2021 (1:00) 11/11/2021 11/11/2021
Misc
Corrective Action Required
11/11/2021
-APPROVED PLANS REQUIRE 8" X 16" FOOTING, SEVERAL AREAS THROUGHOUT FOOTING LESS THAN 8" ON ROCK, HAVE ENGINEER ADDRESS CONDITIONS -PROVIDE SOLID FOOTING FOR GARAGE PIER ON SOIL, SOIL HAS FALLEN BELOW PIER
Footing Inspection - Residential Failed 11/11/2021 11/11/2021
Misc
Corrective Action Required
11/11/2021
-APPROVED PLANS REQUIRE 8" X 16" FOOTING, SEVERAL AREAS THROUGHOUT FOOTING LESS THAN 8" ON ROCK, HAVE ENGINEER ADDRESS CONDITIONS -PROVIDE SOLID FOOTING FOR GARAGE PIER ON SOIL, SOIL HAS FALLEN BELOW PIER
Misc
Informational
11/11/2021
Troy called and stated he will have an Engineer address the footing and Undermined pier in the garage and will submit.
Underslab Plumbing Inspection - Residential Passed 12/8/2021 12/8/2021 12/08/2021
Sewer Service Inspection - R Passed 5/5/2022 (1:00) 5/5/2022 05/05/2022
Water Service Inspection - R Partial 5/5/2022 05/05/2022
Misc
Informational
05/05/2022
pex ran from foundation
Water Service Inspection - R Passed 5/6/2022 (10:45) 5/6/2022 05/06/2022
Misc
Resolved
05/06/2022
pex ran from foundation
Gas Service Inspection - Residential Passed 6/14/2022 06/14/2022
Electrical Service Inspection Passed 6/14/2022 06/14/2022
All Rough Inspection - Residential Failed 6/14/2022 6/14/2022 06/14/2022
Misc
Corrective Action Required
06/14/2022
-complete pfh at all places per plans -anchor bolts to be in the middle 1/3 of sill plate -attic access above single car garage -address front entry wall not tied to garage or master closet wall -fire block furr down ends in garage N wall, dram and furr down -fire block dead pace garage W wall and into furr down -fire block hvac chase into dwv furr down -fire block W wall into all furr downs in garage -furr down joist space used for RA for insulation, pan off and seal penetrations -fire block into furr down in pantry -fire block chase in pantry for dwv/pex into furr down -cspf at dining room slider -cspf master missing straps -2- 2x12 bed 2 per plans -strap top plate where lapped less than 24” bed 3 closet -fireblock stairwell wall into furr down in basement -fireblock ceiling line for wall at bottom or stairs -fire block dead space on basement bath -fireblock furr down in basement bath -anchor all steel columns -fire block ceiling line in basement bedroom and bath
All Rough Inspection - Residential Failed 7/6/2022 7/6/2022 07/06/2022
Misc
Corrective Action Required
06/14/2022
-complete pfh at all places per plans -anchor bolts to be in the middle 1/3 of sill plate -address front entry wall not tied to garage or master closet wall -fire block into furr down in pantry -fire block chase in pantry for dwv/pex into furr down -cspf at dining room slider -fire block dead space on basement bath -fireblock furr down in basement bath -anchor all steel columns
All Rough Inspection - Residential Passed 7/12/2022 7/12/2022 07/12/2022
Misc
Resolved
07/12/2022
-complete pfh at all places per plans -anchor bolts to be in the middle 1/3 of sill plate -address front entry wall not tied to garage or master closet wall -fire block into furr down in pantry -fire block chase in pantry for dwv/pex into furr down -cspf at dining room slider -fire block dead space on basement bath -fireblock furr down in basement bath -anchor all steel columns
Piers/Caissons Inspection - Residential Passed 8/29/2022 (11:15) 8/29/2022 08/29/2022
Driveway Inspection Partial 9/13/2022 09/13/2022
Misc
Informational
09/13/2022
9-13-22 RH. Driveway is formed up and aggregate is placed and compacted.
Sidewalk Inspection Partial 9/13/2022 09/13/2022
Misc
Informational
09/13/2022
9-13-22 RH. Sidewalk is formed up and aggregate is placed and compacted.
Driveway Inspection Passed 9/20/2022 9/20/2022 09/20/2022
Misc
Informational
09/13/2022
9-13-22 RH. Driveway is formed up and aggregate is placed and compacted. 9-20-22 RH. Driveway meets LS specification.
Sidewalk Inspection Passed 9/20/2022 9/20/2022 09/20/2022
Misc
Informational
09/13/2022
9-13-22 RH. Sidewalk is formed up and aggregate is placed and compacted. 9-20-22 RH. Sidewalk meets LS and ADA specification.
Occupancy Inspection - Codes Residential Failed 10/10/2022 10/10/2022 10/10/2022
Misc
Corrective Action Required
10/10/2022
inspection denied address footing inspection not completed.
Footing Inspection - Residential Passed 10/11/2022 10/11/2022
Misc
Resolved
10/11/2022
-APPROVED PLANS REQUIRE 8" X 16" FOOTING, SEVERAL AREAS THROUGHOUT FOOTING LESS THAN 8" ON ROCK, HAVE ENGINEER ADDRESS CONDITIONS -PROVIDE SOLID FOOTING FOR GARAGE PIER ON SOIL, SOIL HAS FALLEN BELOW PIER
Misc
Resolved
10/11/2022
Troy called and stated he will have an Engineer address the footing and Undermined pier in the garage and will submit.
Erosion Control Inspection Residential Passed 10/11/2022 10/11/2022
Plot Plan Inspection Passed 10/11/2022 10/11/2022
Occupancy Inspection - Codes Residential Failed 10/11/2022 10/11/2022 10/11/2022
Misc
Resolved
10/11/2022
inspection denied address footing inspection not completed.
Misc
Corrective Action Required
10/11/2022
-outlets in garage will not reset from GFCI -label all non GFCI outlets in unfinished spaces
Occupancy Inspection - Codes Residential Full C of O 10/12/2022 10/12/2022 10/12/2022
Misc
Resolved
10/12/2022
-outlets in garage will not reset from GFCI -label all non GFCI outlets in unfinished spaces -obtain lawn irrigation permit
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home