Permit Application Status

PRRES20214339


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214339
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED DECK.
08/20/2021
08/30/2021
02/21/2022
07/22/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DREW@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 08/30/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/30/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/30/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/30/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/30/2021
9110078-Valuation Fee New Single Family $1,372.63 $1,372.63 Paid 08/30/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/21/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/21/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/17/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 9/15/2021 09/15/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/15/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - SPREAD GRAVEL FILTER AT DRIVEWAY -
Footing Inspection - Residential Not Ready 9/15/2021 (11:30) 9/15/2021 09/15/2021
Miscellaneous Correction
Corrective Action Required
09/15/2021
NO CITY APPROVED PLANS ON SITE NO ADDRESS POSTED NO GRAVEL FILTER AT DRIVEWAY MAINTAIN SILT FENCE
Underslab Plumbing Inspection - Residential Passed 11/11/2021 11/11/2021 11/11/2021
Sewer Service Inspection - R Passed 12/6/2021 (10:30) 12/6/2021 12/06/2021
Footing Inspection - Residential Passed 12/8/2021 12/08/2021
Miscellaneous Correction
Resolved
12/08/2021
NO CITY APPROVED PLANS ON SITE NO ADDRESS POSTED NO GRAVEL FILTER AT DRIVEWAY MAINTAIN SILT FENCE
Misc
Informational
12/08/2021
3RD PARTY INSPECTION
Water Service Inspection - R Passed 12/8/2021 (1:15) 12/8/2021 12/08/2021
Piers/Caissons Inspection - Residential Passed 2/15/2022 (2:00) 2/15/2022 02/15/2022
Misc
Informational
02/15/2022
(3) 24 x 36 piers
Electrical Service Inspection Passed 3/11/2022 3/11/2022 03/11/2022
Gas Service Inspection - Residential Failed 3/11/2022 3/11/2022 03/11/2022
Miscellaneous Correction
Corrective Action Required
03/11/2022
COMPLETE GAS LINE AT RANGE PROVIDE MIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Failed 3/11/2022 3/11/2022 03/11/2022
Miscellaneous Correction
Corrective Action Required
03/11/2022
Provide anchor bolt within 12" of plate break south wall garage Seal upward penetration south wall garage Tighten anchor bolt single car garage Protect NM conductors coach lights garage Provide anchor bolt end of plate near SCH 40 column garage Fire blocking at soffit garage/house Seal upward penetration behind refrigerator Provide boca plate at pex lines nitch next to HVA C chase kitchen Fire block dead space next to refrigerator Seal floor penetration at range Seal upward penetrations bath 4 Provide midpoint support vertical dwv 2" & smaller Provide nail guard at SEC cable bed #5 Provide H2.5 or truss lock screws bed 5 rear wall Provide stud pack of (4) at each girder truss bearing point per roof plan A6 Provide nail guard at NM dining room/garage Fire block each end of soffit at chase in great room Provide anchor bolts SCH 40 columns basement Complete gas line to range Address cut floor joist under range Install egress window Seal upward penetration above 1st landing at stairway Replace missing stud bed 3 closet Fire block tub traps Seal upward penetrations bed 1 south wall & HVAC chase & shower Vent bath exhaust to exterior master bath Seal upward penetration master closet near door Seal upward penetration dwv near dryer vent box & behind vanity & above washer drain In laundry room Seal upward penetration bed 2 above front door
Gas Service Inspection - Residential Passed 3/17/2022 3/17/2022 03/17/2022
Miscellaneous Correction
Resolved
03/17/2022
All Rough Inspection - Residential Not Ready 3/17/2022 3/17/2022 03/17/2022
Miscellaneous Correction
Corrective Action Required
03/11/2022
Protect NM conductors coach lights garage ( not done 3/17/22) Fire blocking at soffit garage/house (Seal gaps at pex & dwv & fire blocking 3/17/22) Fire block dead space next to refrigerator ( seal gaps 3/17/22) Seal floor penetration at range ( not done 3/17/22) Seal upward penetrations bath 4 ( not done 3/17/22)-- Provide midpoint support vertical dwv 2" & smaller Fire block each end of soffit at chase in great room ( not done 3/17/22) Address cut floor joist under range ( joist hangers need nails 3/17/22) Install egress window Seal upward penetration above 1st landing at stairway ( not done 3/17/22) Fire block tub traps ( still see daylight 3/17/22) Seal upward penetrations HVAC chase & shower ( not done 3/17/22) Seal upward penetration master closet near door ( not done bottom plate below light switch 3/17/22) Seal upward penetration dwv near dryer vent box & behind vanity ( 3/17/22) Seal upward penetration bed 2 above front door ( not done 3/17/22) DO NOT INSULATE 3/17/22
All Rough Inspection - Residential Not Ready 3/23/2022 3/23/2022 03/23/2022
Miscellaneous Correction
Corrective Action Required
03/17/2022
Fire blocking at soffit garage/house (Seal gaps at dwv 3/17/22 not done 3/23 ) Seal upward penetration above 1st landing at stairway ( not done 3/17/22) Seal upward penetrations HVAC chase & shower ( not done 3/17/22 or 3/23/22 ) Seal upward penetration dwv near dryer vent box & behind master vanity ( 3/17/22 still not done 3/23/22 ) DO NOT INSULATE 3/17/22
All Rough Inspection - Residential Passed 3/24/2022 3/24/2022 03/24/2022
Miscellaneous Correction
Resolved
03/24/2022
Fire blocking at soffit garage/house (Seal gaps at dwv 3/17/22 not done 3/23 ) Seal upward penetration above 1st landing at stairway ( not done 3/17/22) Seal upward penetrations HVAC chase & shower ( not done 3/17/22 or 3/23/22 ) Seal upward penetration dwv near dryer vent box & behind master vanity ( 3/17/22 still not done 3/23/22 ) DO NOT INSULATE 3/17/22
Driveway Inspection Partial 3/28/2022 3/28/2022 03/28/2022
Misc
Informational
03/28/2022
Forms were placed and aggregate was present and compacted. RP 3-28-22
Driveway Inspection Passed 4/1/2022 4/1/2022 04/01/2022
Misc
Informational
03/28/2022
Forms were placed and aggregate was present and compacted. RP 3-28-22
Misc
Informational
04/01/2022
Finished driveway meets LS specs. RP 4-1-22
Occupancy Inspection - Codes Residential Failed 6/15/2022 6/15/2022 06/15/2022
Misc
Corrective Action Required
06/15/2022
**Repair erosion control along the street -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension -Provide sewer tracer wire port at grade -Provide a readily accessible receptacle at grade and within 6.5 ft of grade at rear of house -Provide middle deck beam pier support -Screw the exterior deck door embedded jamb brace into studs -Provide 5/8” GB under garage boxed out wall -Provide gfci protection for clothes washer outlet -Support ducting in basement -Securely fasten NM wiring at max 4.5 ft near basement smoke alarm -Label one unlabeled breaker
Plot Plan Inspection Passed 6/16/2022 06/16/2022
Erosion Control Inspection Residential Passed 06/17/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/17/2022
Occupancy Inspection - Codes Residential Temporary C of O 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/15/2022
-sod, splash blocks, sump discharge extension
Occupancy Inspection - Codes Residential Failed 7/8/2022 7/8/2022 07/08/2022
Misc
Corrective Action Required
06/17/2022
-Pay all fees
Occupancy Inspection - Codes Residential Full C of O 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
Documents & Images
Date Uploaded File Type Document Name
08/20/2021 W0 #138 - Permit App
08/24/2021 Approved Plans APPROVED DRAWINGS
08/25/2021 Permit Codes Residential Plan Review
08/27/2021 Plot Plan APPROVED PLOT PLAN
08/27/2021 Approved Plans APPROVED TRUSS LAYOUT
08/27/2021 Approved Plans APPROVED TRUSS PACKAGE
08/27/2021 Permit Codes Residential Plan Review
08/30/2021 Permit DS Building Permit
08/30/2021 Receipt Receipt for transaction:2021-006918
09/15/2021 Letter INSPECTION SUMMARY
09/15/2021 Letter INSPECTION SUMMARY
09/17/2021 138 Woodside Ridge FTNG
11/11/2021 Letter INSPECTION SUMMARY
12/06/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
03/11/2022 Letter INSPECTION SUMMARY
03/11/2022 Letter INSPECTION SUMMARY
03/11/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/21/2022 Receipt Receipt for transaction:2022-001531
03/23/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
06/16/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter Codes Temporary Certificate of Occupancy
07/08/2022 Letter INSPECTION SUMMARY
07/17/2022 Receipt Receipt for transaction:2022-005828
07/22/2022 Letter Field Certificate of Occupancy
07/22/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home