Permit Application Status

PRRES20213784


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213784
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
SINGLE FAMILY HOUSE. FINISHED BASEMENT. COVERED DECK.
07/21/2021
08/02/2021
01/22/2022
10/14/2022
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
BSHELTON@IQHOMEBUILDERS.COM  
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $896.38 $896.38 Paid 08/02/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/02/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/02/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 08/02/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/02/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/02/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/28/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/13/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/23/2021 (3:00) 8/23/2021 08/23/2021
Underslab Plumbing Inspection - Residential Passed 10/8/2021 10/8/2021 10/08/2021
Piers/Caissons Inspection - Residential Failed 1/18/2022 (8:00) 1/18/2022 01/18/2022
Misc
Corrective Action Required
01/18/2022
not drilled per plans
Piers/Caissons Inspection - Residential Passed 1/21/2022 (1:00) 1/21/2022 01/21/2022
Misc
Resolved
01/21/2022
not drilled per plans
Erosion Control Inspection Residential Failed 1/21/2022 01/21/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/21/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 1:37 PM
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/21/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO INSPECTION(S) BEING PERFORMED.
Gas Service Inspection - Residential Passed 3/3/2022 3/3/2022 03/03/2022
Electrical Service Inspection Failed 3/3/2022 3/3/2022 03/03/2022
Misc
Corrective Action Required
03/03/2022
-Connect GEC to middle grounded bus bar
All Rough Inspection - Residential Failed 3/3/2022 3/3/2022 03/03/2022
Misc
Corrective Action Required
03/03/2022
-fire block south end furr down in garage -connect GEC to middle grounded bus bar -Secure fire blocking insulation in place -fire block north basement wall -complete dryer vent wall and fire block -complete attic access -add support for ridge above living room/kitchen wall -receptacle required right of back door wall space greater than 2’
Water Service Inspection - R Partial 3/11/2022 03/11/2022
Misc
Informational
03/11/2022
PARTIAL WATER HOUSE TO MIDDLE OF FRONT YARD
Sewer Service Inspection - R Passed 3/11/2022 03/11/2022
Water Service Inspection - R Passed 3/14/2022 (9:45) 3/14/2022 03/14/2022
Misc
Resolved
03/14/2022
PARTIAL WATER HOUSE TO MIDDLE OF FRONT YARD
Erosion Control Inspection Residential Failed 3/17/2022 03/17/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
03/17/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 01/21/2022 1:37 PM
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
03/17/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO INSPECTION(S) BEING PERFORMED.
DCM5 ESC INSP DENIED
Corrective Action Required
03/17/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Electrical Service Inspection Failed 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/03/2022
inspection denied, erosion control not in compliance -Connect GEC to middle grounded bus bar
All Rough Inspection - Residential Failed 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/03/2022
inspection denied, erosion control not in compliance -fire block south end furr down in garage -connect GEC to middle grounded bus bar -Secure fire blocking insulation in place -fire block north basement wall -complete dryer vent wall and fire block -complete attic access -add support for ridge above living room/kitchen wall -receptacle required right of back door wall space greater than 2’
All Rough Inspection - Residential Passed 3/21/2022 3/21/2022 03/21/2022
Misc
Resolved
03/21/2022
inspection denied, erosion control not in compliance -fire block south end furr down in garage -connect GEC to middle grounded bus bar -Secure fire blocking insulation in place -fire block north basement wall -complete dryer vent wall and fire block -complete attic access -add support for ridge above living room/kitchen wall -receptacle required right of back door wall space greater than 2’
Electrical Service Inspection Passed 3/21/2022 3/21/2022 03/21/2022
Misc
Resolved
03/21/2022
inspection denied, erosion control not in compliance -Connect GEC to middle grounded bus bar
Erosion Control Inspection Residential Failed 3/21/2022 3/21/2022 03/21/2022
DCM5 ESC INSP DENIED
Resolved
03/21/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Misc
Corrective Action Required
03/21/2022
MAINTAIN GRAVEL DRIVE
Occupancy Inspection - Codes Residential Failed 6/28/2022 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/28/2022
EROSION CONTROL TO BE IN COMPLIANCE BEFORE ANY FURTHER INSPECTIONS -address drive way and sidewalk inspection pending -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -obtain lawn irrigation permit -check water meter at time of final grade and sod -handrail for stairs to kitchen to be code compliant see bottom of hand rail code section 311.7.8.4 -tempered glass at window near back door -security screws at back door hinges and strike plates -security screws at front door strike plates -hand rail at front entry steps to comply with code section 312.1.3 -secure A/c whip within 12” of disconnect -2 1/2” through bolts at each deck post to beam connection
Occupancy Inspection - Codes Residential Temporary C of O 6/29/2022 6/29/2022 06/29/2022
Misc
Corrective Action Required
06/28/2022
TCO UNTIL 7/29/22 -address drive way and sidewalk inspection pending -final grade and sod -gutters to be installed -splash blocks and sump pump discharge to extend 36” from foundation -obtain lawn irrigation permit -check water meter at time of final grade and sod
Plot Plan Inspection Failed 8/9/2022 08/09/2022
Misc
Corrective Action Required
08/09/2022
uncover covered man hole
Occupancy Inspection - Codes Residential Failed 8/19/2022 08/19/2022
Misc
Corrective Action Required
06/29/2022
submit tco extension reqest fourm. Mitchell Schwarz 08/19/2022 10:35 AM TCO UNTIL 7/29/22 -address drive way and sidewalk inspection pending -final grade and sod -gutters to be installed -splash blocks and sump pump discharge to extend 36” from foundation -obtain lawn irrigation permit -check water meter at time of final grade and sod
Erosion Control Inspection Residential Passed 9/12/2022 09/12/2022
Misc
Resolved
09/12/2022
MAINTAIN GRAVEL DRIVE
Occupancy Inspection - Codes Residential Not Ready 9/12/2022 9/12/2022 09/12/2022
Misc
Corrective Action Required
08/19/2022
NO FURTHER INSPECTIONS UNTIL TCO EXTENSION REQUEST FORM IS SUBMITTED AND FEES ARE PAID. Mitchell Schwarz 09/12/2022 9:37 AM submit tco extension request form. Mitchell Schwarz 08/19/2022 10:35 AM TCO UNTIL 7/29/22 -pay all fees -address drive way and sidewalk inspection pending -obtain lawn irrigation permit -check water meter at time of final grade and sod -address plot plan still not passed see notes on plot plan man hole covered
Driveway Inspection Passed 9/29/2022 9/29/2022 09/29/2022
Misc
Informational
09/29/2022
9-29-22 RH. Driveway meets LS and ADA specification.
Sidewalk Inspection Failed 9/29/2022 9/29/2022 09/29/2022
Misc
Corrective Action Required
09/29/2022
9-29-22 RH. Sidewalk met ADA specification but there were two cracked panels that will need replaced.
Occupancy Inspection - Codes Residential Ready for Temp CO 9/30/2022 9/29/2022 09/29/2022
Misc
Corrective Action Required
09/12/2022
NO FURTHER INSPECTIONS UNTIL TCO EXTENSION REQUEST FORM IS SUBMITTED AND FEES ARE PAID. Mitchell Schwarz 09/12/2022 9:37 AM submit tco extension request form. Mitchell Schwarz 08/19/2022 10:35 AM TCO UNTIL 7/29/22 -pay all fees -address drive way and sidewalk inspection pending -obtain lawn irrigation permit -check water meter at time of final grade and sod -address plot plan still not passed see notes on plot plan man hole covered
Sidewalk Inspection Partial 10/3/2022 10/3/2022 10/03/2022
Misc
Corrective Action Required
09/29/2022
9-29-22 RH. Sidewalk met ADA specification but there were two cracked panels that will need replaced. 10-3-22 RH. Sidewalk is formed up and aggregate is placed and compacted.
Sidewalk Inspection Passed 10/13/2022 10/13/2022 10/13/2022
Misc
Corrective Action Required
10/03/2022
9-29-22 RH. Sidewalk met ADA specification but there were two cracked panels that will need replaced. 10-3-22 RH. Sidewalk is formed up and aggregate is placed and compacted. 10-13-22 RH. Sidewalk meets LS and ADA specification.
Plot Plan Inspection Passed 10/14/2022 10/14/2022
Misc
Resolved
10/14/2022
uncover covered man hole
Occupancy Inspection - Codes Residential Full C of O 10/14/2022 10/14/2022 10/14/2022
Misc
Corrective Action Required
09/29/2022
-check water meter at time of final grade and sod -address plot plan still not passed see notes on plot plan man hole covered
Documents & Images
Date Uploaded File Type Document Name
07/21/2021 Application Form PERMIT APPLICATION
07/26/2021 Permit Codes Residential Plan Review
07/30/2021 Approved Plans APPROVED DRAWINGS
07/30/2021 Permit Codes Residential Plan Review
08/02/2021 Permit DS Building Permit
08/02/2021 Receipt Receipt for transaction:2021-006147
08/12/2021 Plot Plan APPROVED PLOT PLAN
08/23/2021 Letter INSPECTION SUMMARY
10/08/2021 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
03/11/2022 Letter INSPECTION SUMMARY
03/11/2022 Letter INSPECTION SUMMARY
03/14/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/21/2022 Letter INSPECTION SUMMARY
03/21/2022 Letter INSPECTION SUMMARY
03/21/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter Codes Temporary Certificate of Occupancy
08/08/2022 Plot Plan Approved As Graded Plot Plan
08/09/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
09/28/2022 Receipt Receipt for transaction:2022-007874
09/29/2022 2617 SW River Trail - TCO Extension Form
09/29/2022 Letter INSPECTION SUMMARY
09/29/2022 Letter INSPECTION SUMMARY
09/30/2022 Cracked panels
09/30/2022 Cracked Sidewalk
09/30/2022 Cracked sidewalk0
09/30/2022 Cracked Sidewalk1
10/03/2022 Letter INSPECTION SUMMARY
10/13/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/13/2022 Receipt Receipt for transaction:2022-008246
10/13/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter Codes Final Certificate of Occupancy
10/14/2022 Letter Field Certificate of Occupancy
10/14/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home