Permit Application Status

PRRES20213631


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213631
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK TILE ROOF
07/14/2021
07/20/2021
08/11/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
MIKE@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Right of Way Permit Fee $80.00 $80.00 Paid 07/20/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/20/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 07/20/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 07/20/2021
Water Meter Fee $479.24 $479.24 Paid 07/20/2021
Valuation Fee New Single Family $1,183.22 $1,183.22 Paid 07/20/2021
3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 07/06/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 11/9/2021 11/9/2021 11/09/2021
Misc
Corrective Action Required
11/09/2021
no address no erosion control. no gravel filter, silt fence
Underslab Plumbing Inspection - Residential Passed 11/30/2021 11/30/2021 11/30/2021
Misc
Corrective Action Required
11/09/2021
Erosion Control Inspection Residential Failed 11/30/2021 11/30/2021
Misc
Corrective Action Required
11/30/2021
Footing Inspection - Residential Failed 11/30/2021 11/30/2021
Misc
Corrective Action Required
11/30/2021
footing poured without inspection.
Sewer Service Inspection - R Passed 11/30/2021 (10:00) 11/30/2021 11/30/2021
Water Service Inspection - R Passed 12/1/2021 (9:15) 12/1/2021 12/01/2021
Footing Inspection - Residential Passed 12/1/2021 12/01/2021
Misc
Resolved
12/01/2021
footing poured without inspection.
Misc
Informational
12/01/2021
3rd party footing by derek perez @ everstead signed & sealed by bradley huxol ufer located southeast (right rear) corner of garage foundation wall
Electrical Service Inspection Passed 4/6/2022 4/6/2022 04/06/2022
Gas Service Inspection - Residential Failed 4/6/2022 04/06/2022
Miscellaneous Correction
Corrective Action Required
04/06/2022
CONNECT GAS LINE TO FIREPLACE SHIELD GAS LINE AT FIREPLACE SECURE GAS LINE AT FIREPLACE PROVIDE MIN 10 PSI FOR 15 MIN
Erosion Control Inspection Residential Failed 4/6/2022 04/06/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/30/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER MAINTAIN GUTTER BUDDY CLEAN SEDIMENT BUILD UP AT CURB INLET
All Rough Inspection - Residential Failed 4/6/2022 4/6/2022 04/06/2022
Miscellaneous Correction
Corrective Action Required
04/06/2022
Post address Secure fireplace Secure gas line at fire place Shield gas line at fire place Seal fire blocking above fire place Provide hangers per truss layout Provide H2.5 both hip girder trusses A-1 both ends Provide H2.5 truss A10 bath 2 Provide H2.5a trusses D2 front porch Seal upward penetration front porch garage side Install sliding glass door at deck Provide CS-PF per plan at sliding glass door Provide Boca plate at master vanity Address over bored studs at master vanity Seal floor penetration master vanity Seal upward penetration bed 2 - bath 2 Provide anchor bolt end of plate rear single car garage anchor bolts shall be in middle 1/3 the width of plate Tighten anchor bolt at single car door Seal fire blocking above landing window Provide joist hangers at cantilever under fireplace Apply sheathing to interior side of wall at patio door per plan Provide 3 studs exterior wall corner bed 4 Provide boca plate dwv under beam bed 4 Furr out dwv at ceiling bed 4 closet Seal upward penetrations bath 3
All Rough Inspection - Residential Failed 4/15/2022 4/15/2022 04/15/2022
Miscellaneous Correction
Corrective Action Required
04/06/2022
-Provide CS-PF per plan at sliding glass door -Apply sheathing to interior side of wall at patio door per plan -Provide 3 studs exterior wall corner bed 4 -Furr out dwv at ceiling bed 4 closet,(fireblock around DWV top plate, will need bocca plate as well) ok to insulate
Gas Service Inspection - Residential Passed 4/20/2022 04/20/2022
Miscellaneous Correction
Resolved
04/20/2022
All Rough Inspection - Residential Passed 4/20/2022 4/20/2022 04/25/2022
Miscellaneous Correction
Resolved
04/25/2022
Driveway Inspection Partial 5/23/2022 5/23/2022 05/23/2022
Misc
Informational
05/23/2022
Driveway was framed up with aggregate in and compacted. 5/23/22 ES
Sidewalk Inspection Partial 5/23/2022 5/23/2022 05/23/2022
Misc
Informational
05/23/2022
Sidewalk was framed up with aggregate in and compacted. 5/23/22 ES
Driveway Inspection Passed 6/6/2022 6/6/2022 06/06/2022
Misc
Informational
05/23/2022
Driveway was framed up with aggregate in and compacted. 5/23/22 ES Driveway meets LS and ADA spec. 6/6/22 ES
Sidewalk Inspection Passed 6/6/2022 6/6/2022 06/06/2022
Misc
Informational
05/23/2022
Sidewalk was framed up with aggregate in and compacted. 5/23/22 ES Sidewalk meets LS and ADA spec. 6/6/22 ES
Piers/Caissons Inspection - Residential Failed 07/05/2022
Misc
Informational
07/05/2022
Third party inspecto used.
Piers/Caissons Inspection - Residential Passed 07/05/2022
Misc
Informational
07/05/2022
Third party inspecto used.
Occupancy Inspection - Codes Residential Failed 7/5/2022 7/5/2022 07/05/2022
Misc
Corrective Action Required
07/05/2022
pay all fees Irrigation permit if needed Missing outlet covers kitchen back splash Cover DWV in basement Security screws in basement entry door Splash blocks Final grading and sod
Erosion Control Inspection Residential Passed 07/05/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/05/2022
Occupancy Inspection - Codes Residential Temporary C of O 7/8/2022 7/8/2022 07/08/2022
Misc
Corrective Action Required
07/05/2022
Splash blocks Final grading and sod
Occupancy Inspection - Codes Residential Failed 7/15/2022 7/15/2022 07/15/2022
Misc
Corrective Action Required
07/08/2022
- Lower water meter lid.
Plot Plan Inspection Passed 07/15/2022
Occupancy Inspection - Codes Residential Full C of O 8/11/2022 8/11/2022 08/11/2022
Misc
Resolved
08/11/2022
Documents & Images
Date Uploaded File Type Document Name
07/14/2021 W1 #28 - Permit App
07/14/2021 Approved Plans Approved Drawings
07/14/2021 Approved Plans Approved Truss Layout
07/14/2021 Approved Plans Approved Truss Package
07/14/2021 Plot Plan Approved Plot Plan
07/14/2021 Permit Codes Residential Plan Review
07/20/2021 Permit DS Building Permit
07/20/2021 Receipt Receipt for transaction:2021-005778
11/09/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/01/2021 W1-28 Footing inspection
12/01/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/06/2022 Letter INSPECTION SUMMARY
04/14/2022 28 woodside ridge letter #3
04/15/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
07/05/2022 Letter INSPECTION SUMMARY
07/05/2022 Letter INSPECTION SUMMARY
07/06/2022 Receipt Receipt for transaction:2022-005527
07/08/2022 Letter Codes Temporary Certificate of Occupancy
07/08/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter Field Certificate of Occupancy
08/11/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home