Permit Application Status

PRRES20213528


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213528
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED/UNFINISHED BASEMENT - COVERED DECK WALKOUT/WALKUP BASEMENT LETTER APPROVED BY OLSSON ENGINEERING
07/08/2021
07/29/2021
01/23/2022
09/30/2022
Locations
Contacts
SAB CONSTRUCTION LLC, Address:PO BOX 942, Phone:(816) 524-3855  
JIM@SABHOMES.COM  
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,163.34 $1,163.34 Paid 07/29/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/29/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/29/2021
8331507-Sewer Connection Fee $480.00 $480.00 Paid 07/29/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 07/29/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 07/29/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/30/2021 09/30/2021
Misc
Informational
09/30/2021
Footing approved by David Ainsworth on 9-22-21
Erosion Control Inspection Residential Failed 9/30/2021 9/30/2021 09/30/2021
Misc
Corrective Action Required
09/30/2021
9-30-21 -Restore erosion control at perimeter of lot and gravel filter before any further inspections
Piers/Caissons Inspection - Residential Passed 10/26/2021 (10:15) 10/26/2021 10/26/2021
Miscellaneous Correction
Resolved
10/26/2021
Underslab Plumbing Inspection - Residential Passed 10/27/2021 10/27/2021 10/27/2021
Sewer Service Inspection - R Passed 2/11/2022 (11:00) 2/11/2022 02/11/2022
Water Service Inspection - R Partial 2/11/2022 02/11/2022
Water Service Inspection - R Passed 2/15/2022 02/15/2022
Erosion Control Inspection Residential Failed 3/15/2022 03/15/2022
Misc
Resolved
03/15/2022
9-30-21 -Restore erosion control at perimeter of lot and gravel filter before any further inspections
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/15/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence down along SW side of lot as well as front of lot
DCM5 ESC INSP DENIED
Corrective Action Required
03/29/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -maintain gravel filter -maintain silt fence
Erosion Control Inspection Residential Failed 3/29/2022 03/29/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/15/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence down along SW side of lot as well as front of lot
DCM5 ESC INSP DENIED
Corrective Action Required
03/29/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -maintain gravel filter -maintain silt fence
All Rough Inspection - Residential Failed 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/29/2022
Inspection denied due to erosion control not in compliance
Electrical Service Inspection Failed 3/31/2022 3/31/2022 03/31/2022
Miscellaneous Correction
Corrective Action Required
03/31/2022
Provide proper clamp for aluminum conductor to steel ufer. Acorn not suitable for this location
Gas Service Inspection - Residential Passed 3/31/2022 3/31/2022 03/31/2022
All Rough Inspection - Residential Failed 3/31/2022 3/31/2022 03/31/2022
Misc
Corrective Action Required
03/29/2022
-Provide straps for PFG small garage - Nail header to top plate with 2 rows of 16 D sinkers@ 3” oc - Provide 3” oc nail pattern to header on PFG & PFH portal frames - Address notched joist north east corner single garage - Fire block penetration in plenum space bedroom 2 at closet - Fire block DWV in return air space master bathroom - Address over notched joist north west corner of office - Fire block penetration return air space at office - Fire block soffit basement bathroom at stairs - Provide Boca plate DWV floor at basement bathroom near stairs - Fire block fur out soffit to joist space through out basement - Fire block chase at column adjacent from slider basement, horizontal to chase and joist space - Provide 3 1/2” steel columns both sides of gaming room per plan - Seal return air pan out, basement hallway near bathroom - Fire block penetration in plenum space bedroom 4 basement
All Rough Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
03/31/2022
- Fire block DWV in return air space master bathroom (at stud shoe) - Provide 3 1/2” steel columns both sides of gaming room per plan - Fire block penetration in plenum space bedroom 4 basement
Electrical Service Inspection Failed 4/7/2022 4/7/2022 04/07/2022
Miscellaneous Correction
Corrective Action Required
03/31/2022
Provide proper clamp for aluminum conductor to steel ufer. Acorn not suitable for this location 4/7/22 no change
All Rough Inspection - Residential Not Ready 4/13/2022 4/13/2022 04/13/2022
Misc
Corrective Action Required
04/07/2022
- Fire block DWV in return air space master bathroom (at stud shoe) - Provide 3 1/2” steel columns both sides of gaming room per plan - Fire block penetration in plenum space bedroom 4 basement
Misc
Corrective Action Required
04/13/2022
inspection denied no address posted erosion control not in compliance
Electrical Service Inspection Failed 4/13/2022 4/13/2022 04/13/2022
Miscellaneous Correction
Corrective Action Required
04/07/2022
Provide proper clamp for aluminum conductor to steel ufer. Acorn not suitable for this location 4/7/22 no change
Misc
Corrective Action Required
04/13/2022
inspection denied no address erosion control not in compliance
Erosion Control Inspection Residential Failed 4/13/2022 04/13/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
04/13/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence down along SW side of lot as well as front of lot
DCM5 ESC INSP DENIED
Resolved
04/13/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -maintain gravel filter -maintain silt fence
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/13/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. maintain silt fence
Erosion Control Inspection Residential Failed 4/19/2022 04/19/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/19/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. maintain silt fence
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/19/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. maintain gravel filter
All Rough Inspection - Residential Failed 4/19/2022 4/19/2022 04/19/2022
Misc
Corrective Action Required
04/13/2022
- Provide 3 1/2” steel columns both sides of gaming room per plan - Seal penetration in RA at bed 4 in furr down Okay to insulate, do not cover any items still in need of inspection.
Misc
Resolved
04/19/2022
inspection denied no address posted erosion control not in compliance
All Rough Inspection - Residential Passed 4/22/2022 4/22/2022 04/22/2022
Misc
Resolved
04/22/2022
Misc
Resolved
04/22/2022
inspection denied no address posted erosion control not in compliance
Erosion Control Inspection Residential Passed 4/22/2022 04/22/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
04/22/2022
Electrical Service Inspection Passed 5/10/2022 5/10/2022 05/10/2022
Miscellaneous Correction
Resolved
05/10/2022
Provide proper clamp for aluminum conductor to steel ufer. Acorn not suitable for this location 4/7/22 no change
Misc
Resolved
05/10/2022
inspection denied no address erosion control not in compliance
Driveway Inspection Partial 7/14/2022 7/14/2022 07/14/2022
Misc
Informational
07/14/2022
On 7.14.2022 I conducted a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Partial 7/14/2022 7/14/2022 07/14/2022
Misc
Informational
07/14/2022
On 7.14.2022 I conducted a sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 8/8/2022 (11:00) 8/8/2022 08/08/2022
Misc
Informational
07/14/2022
On 7.14.2022 I conducted a driveway inspection and pass the subgrade to pour concrete 8.8.2022 Driveway appears to be compliant
Sidewalk Inspection Passed 8/8/2022 (11:00) 8/8/2022 08/08/2022
Misc
Informational
07/14/2022
On 7.14.2022 I conducted a sidewalk inspection and pass the subgrade to pour concrete 8.8.2022 Sidewalk appears to be compliant
Occupancy Inspection - Codes Residential Failed 9/23/2022 9/23/2022 09/23/2022
Misc
Corrective Action Required
09/23/2022
-Pay all fees -Clean debris from storm inlet and remove gutter buddy -Provide AFCI protection and lockouts per code -Provide bonding of whirpool motor per E4209.5 and manufacturer -Missing cover plates at basement bar -Provide secondary lock at SGD -Provide ledger attachment and missing hangers at deck
Plot Plan Inspection Passed 9/23/2022 09/23/2022
Occupancy Inspection - Codes Residential Full C of O 9/30/2022 9/30/2022 09/30/2022
Misc
Resolved
09/30/2022
-Provide AFCI protection and lockouts per code -Provide bonding of whirpool motor per E4209.5 and manufacturer -Missing cover plates at basement bar -Provide secondary lock at SGD -Provide ledger attachment and missing hangers at deck
Documents & Images
Date Uploaded File Type Document Name
07/08/2021 Application Form Permit Application
07/14/2021 Application Form License Tax Form
07/26/2021 E728 - Air Combustion Calculation
07/26/2021 E728 - Letter from Olsson
07/26/2021 E728 - Final Engineered Plans
07/26/2021 Approved Plans Approved Drawings
07/27/2021 Permit Codes Residential Plan Review
07/27/2021 Plot Plan Approved Plot Plan
07/27/2021 Permit Codes Residential Plan Review
07/29/2021 Permit DS Building Permit
07/29/2021 Receipt Receipt for transaction:2021-006043
09/29/2021 M L Crose 2361 SW Old Port Rd LSMO Eagle Creek Lot 728 SAB Homes P 2021-3528 3rd Party Footing Inspection Report 9-22-21
09/30/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
10/26/2021 Letter INSPECTION SUMMARY
10/26/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/13/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
08/25/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/28/2022 Receipt Receipt for transaction:2022-007850
09/30/2022 Letter Field Certificate of Occupancy
09/30/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home