Summary
PRRES20213493
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 08/26/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 08/30/2021 12:00 AM by username 'Patrick Schonfeldt'.
07/07/2021
07/08/2021
01/04/2022
08/10/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $510.00 $510.00 Paid 07/08/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 07/08/2021
Water Meter Fee $479.24 $479.24 Paid 07/08/2021
Right of Way Permit Fee $80.00 $80.00 Paid 07/08/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/08/2021
Valuation Fee New Single Family $1,372.70 $1,372.70 Paid 07/08/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 8/25/2021 (1:00) 8/25/2021 08/25/2021
Water Service Inspection - R Passed 8/26/2021 08/26/2021
Erosion Control Inspection Residential Failed 8/26/2021 8/26/2021 08/26/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/26/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Footing Inspection - Residential Failed - Stop Work 8/26/2021 8/26/2021 08/26/2021
Misc
Corrective Action Required
08/26/2021
STOP WORK ISSUED FOOTING POURED WITHOUT INSPECTION, ENGINEER REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Passed 8/30/2021 8/30/2021 08/30/2021
Misc
Informational
08/30/2021
APPROVED PER BRADLEY HUXOL 7/26/21
Underslab Plumbing Inspection - Residential Passed 8/31/2021 8/31/2021 08/31/2021
Gas Service Inspection - Residential Failed 3/18/2022 03/18/2022
Electrical Service Inspection Passed 3/18/2022 03/18/2022
All Rough Inspection - Residential Failed 3/18/2022 3/18/2022 03/18/2022
Misc
Corrective Action Required
03/18/2022
-PFH per plans and design -fire block dwv into hvac chase at pantry -secure and protect gas line at fire place. -complete gas line install at fire place -address studs boarded left of fire place must have minimum 5/8” to edge -midway strap all down 2” or less in diameter -add over notched stud above bath 3 -fire block behind bath 1 shower -protect NM with in 6’ of attic access -missing stud bath 2 wall -fire block stairwell to garage wall (staircase to basement) -3 2x10 joist per plans S wall basement -solid blocking 48” OC under kitchen island and one joist bay past each side -address framing in between stairwell
Gas Service Inspection - Residential Failed 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/29/2022
inspection denied maintain erosion control -gravel filter
All Rough Inspection - Residential Failed 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/18/2022
Inspection denied due to erosion control Mitchell Schwarz 03/29/2022 8:54 AM -PFH per plans and design -fire block dwv into hvac chase at pantry -secure and protect gas line at fire place. -complete gas line install at fire place -address studs boarded left of fire place must have minimum 5/8” to edge -midway strap all down 2” or less in diameter -add over notched stud above bath 3 -fire block behind bath 1 shower -protect NM with in 6’ of attic access -missing stud bath 2 wall -fire block stairwell to garage wall (staircase to basement) -3 2x10 joist per plans S wall basement -solid blocking 48” OC under kitchen island and one joist bay past each side
Erosion Control Inspection Residential Failed 3/29/2022 03/29/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/29/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM5 ESC INSP DENIED
Corrective Action Required
03/29/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. maintain gravel filter
Gas Service Inspection - Residential Passed 4/1/2022 4/1/2022 04/01/2022
Misc
Resolved
04/01/2022
inspection denied maintain erosion control -gravel filter
All Rough Inspection - Residential Failed 4/1/2022 4/1/2022 04/01/2022
Misc
Corrective Action Required
03/29/2022
-fire block dwv into hvac chase at pantry -address over notched joist above bath 3 -fire block behind bath 1 shower SEAL GAPS -fire block stairwell to garage wall (staircase to basement)
Erosion Control Inspection Residential Partial 4/1/2022 04/01/2022
DCM5 ESC INSP DENIED
Resolved
04/01/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. maintain gravel filter
Misc
Informational
04/01/2022
Erosion control back in compliance Mitchell Schwarz 04/01/2022 9:50 AM
All Rough Inspection - Residential Failed 4/5/2022 4/5/2022 04/05/2022
Misc
Corrective Action Required
04/01/2022
-address over notched joist above bath 3 (nail to engineer letter specifications
All Rough Inspection - Residential Passed 4/8/2022 4/8/2022 04/08/2022
Misc
Resolved
04/08/2022
-address over notched joist above bath 3 (nail to engineer letter specifications
Driveway Inspection Passed 5/10/2022 5/10/2022 05/11/2022
Sidewalk Inspection Passed 5/11/2022 05/11/2022
Misc
Informational
05/11/2022
Sidewalk passed
Plot Plan Inspection Passed 7/27/2022 07/27/2022
Piers/Caissons Inspection - Residential Passed 7/29/2022 07/29/2022
Misc
Informational
07/29/2022
Addressed in third party footing inspection
Occupancy Inspection - Codes Residential Failed 7/29/2022 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/29/2022
-address pending drive way inspection -handrail at garage stairs -properly illuminate home address -cover for outlet by A/c unit -seal all exterior penetrations
Sidewalk Inspection Passed 5/10/2022 5/10/2022 08/02/2022
Driveway Inspection Passed 08/02/2022
Misc
Informational
08/02/2022
On Tuesday, 8-02-2022. I performed a visual inspection of the property and found all street signs installed causing the the sign off of the permit.
Erosion Control Inspection Residential Passed 8/10/2022 08/10/2022
Misc
Resolved
08/10/2022
Erosion control back in compliance Mitchell Schwarz 04/01/2022 9:50 AM
Occupancy Inspection - Codes Residential Full C of O 8/10/2022 8/10/2022 08/10/2022
Misc
Resolved
08/10/2022
-address pending drive way inspection -handrail at garage stairs -properly illuminate home address -cover for outlet by A/c unit -seal all exterior penetrations
Documents & Images
Date Uploaded File Type Document Name
07/07/2021 H4 #128 - PERMIT APPLICATION
07/08/2021 Approved Plans Approved Drawings
07/08/2021 Approved Plans Approved Truss Layout
07/08/2021 Approved Plans Approved Truss Package
07/08/2021 Permit Codes Residential Plan Review
07/08/2021 Plot Plan Approved Plot Plan
07/08/2021 Permit Codes Residential Plan Review
07/08/2021 Permit DS Building Permit
07/08/2021 Receipt Receipt for transaction:2021-005490
08/25/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter Stop Work Order
08/27/2021 128 Hawthorne Ridge FTNG
08/30/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/04/2022 H4 128 Field Issue Letter
04/05/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
07/26/2022 Plot Plan Approved As Graded Plot Plan
07/29/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter Codes Final Certificate of Occupancy
08/10/2022 Letter Field Certificate of Occupancy
08/10/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home