Permit Application Status

PRRES20213400


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213400
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
07/01/2021
07/06/2021
05/23/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 07/06/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 07/06/2021
Water Meter Fee $479.24 $479.24 Paid 07/06/2021
Right of Way Permit Fee $80.00 $80.00 Paid 07/06/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/06/2021
Valuation Fee New Single Family $873.72 $873.72 Paid 07/06/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/22/2021 7/22/2021 07/22/2021
Misc
Informational
07/22/2021
-APPROVED PER BRADLEY HUXOL 7/20/21
Sewer Service Inspection - R Passed 9/1/2021 (8:15) 9/1/2021 09/01/2021
Water Service Inspection - R Passed 9/2/2021 (10:45) 9/2/2021 09/02/2021
Erosion Control Inspection Residential Failed 9/2/2021 9/2/2021 09/02/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/02/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 9/3/2021 9/3/2021 09/03/2021
Misc
Corrective Action Required
09/03/2021
POST ADDRESS
Gas Service Inspection - Residential Passed 2/22/2022 2/22/2022 02/22/2022
Electrical Service Inspection Passed 2/22/2022 2/22/2022 02/22/2022
All Rough Inspection - Residential Failed 2/22/2022 2/22/2022 02/22/2022
Misc
Corrective Action Required
02/22/2022
-maintain gravel filter -attic access required -Anchor bolts to be within 12” of plate breaks -address stud not full length in garage south wall -all hangers nailed off multiple hangers throughout house not nailed off completely -snow blocking sheathing breaks bed 2 -h2.5 at all truss bearing points -strap top plate above fireplace -fire block bath seat in bath 1 -seal all holes in bath 1 floor -fire block bath one ceiling line N wall -sold block cripple wall at entry where load bearing -plans call for (2) 2x6 at basement slider -fire block furr down end in bed 4 left of window -address stud spacing at dwv in basement bath 3 -land NM in bed 4 -solid blocking under kitchen island per plans -dining room window exterior per plans
All Rough Inspection - Residential Passed 2/25/2022 2/25/2022 02/25/2022
Misc
Resolved
02/25/2022
Driveway Inspection Passed 3/31/2022 3/31/2022 03/31/2022
Misc
Informational
03/31/2022
On Thursday, 3-31-2022, I performed a drive approach inspection and passed drive for concrete placement.
Sidewalk Inspection Passed 3/31/2022 3/31/2022 03/31/2022
Misc
Informational
03/31/2022
On Thursday, 3-31-2022. I performed and passed a sidewalk inspection
Piers/Caissons Inspection - Residential Passed 5/5/2022 05/05/2022
Occupancy Inspection - Codes Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
05/05/2022
-provide set screw sheered off at water anti siphon device. -final grade and sod -seal top of meter can, A/C disconnect and all other exterior penitrations -check water meter and pit at time of final grade and sod
Occupancy Inspection - Codes Residential Temporary C of O 5/9/2022 5/9/2022 05/09/2022
Misc
Corrective Action Required
05/05/2022
TCO UNTIL 6/9/22 -sod -seal top of meter can, A/C disconnect and all other exterior penitrations -check water meter and pit at time of final grade and sod -submit as graded plot plan
Plot Plan Inspection Passed 5/12/2022 05/12/2022
Erosion Control Inspection Residential Passed 05/23/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/02/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Full C of O 5/23/2022 5/23/2022 05/23/2022
Misc
Resolved
05/23/2022
Documents & Images
Date Uploaded File Type Document Name
07/01/2021 H3 #10 - PERMIT APP
07/01/2021 Approved Plans Approved Drawings
07/01/2021 Approved Plans Approved Truss Layout
07/01/2021 Approved Plans Approved Truss Package
07/01/2021 Plot Plan Approved Plot Plan
07/06/2021 Permit Codes Residential Plan Review
07/06/2021 Permit DS Building Permit
07/06/2021 Receipt Receipt for transaction:2021-005358
07/21/2021 Lot 10 Hawthorne Ridge Footing Inspection
07/21/2021 Lot 10 Hawthorne Ridge Footing Inspection
07/22/2021 Letter INSPECTION SUMMARY
09/01/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/25/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter Codes Temporary Certificate of Occupancy
05/11/2022 Plot Plan Approved As Graded Plot Plan
05/12/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter Field Certificate of Occupancy
05/23/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home