Summary
PRRES20212683
Building Permit - Residential
Temporary Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - UNCOVERED PATIO
05/24/2021
06/10/2021
11/21/2021
Locations
Contacts
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
JP Roberts, Address:4335 McGee St  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,078.26 $0.00 Paid 07/15/2022
$1,077.12
Right of Way Permit Fee $80.00 $0.00 Paid 07/15/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/25/2021
$1,077.12
8331507-Sewer Connection Fee $450.00 $0.00 Paid 07/15/2022
Water Tap Fee $3,581.00 $0.00 Paid 07/15/2022
Water Meter Fee $455.54 $0.00 Paid 07/15/2022
New Longview Road and Bridge Escrow $1,077.12 $0.00 Paid 07/15/2022
Valuation Fee New Single Family $409.61 $409.61 Paid 07/15/2022
$1,487.87
Temporary Occupancy Fee $50.00 $50.00 Paid 09/16/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 03/14/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/14/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/14/2024
Outstanding Fees Amount Paid Owing Date Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$950.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Occupancy Inspection - Codes Residential Pending
Miscellaneous Correction
Corrective Action Required
12/09/2025
- Provide splash blocks - Obtain an irrigation permit and submit a back flow certification - Pay back fees for each 30 days of TCO - submit request form
Footing Inspection - Residential Passed 8/2/2021 (1:15) 8/2/2021 08/02/2021
Erosion Control Inspection Residential Failed 8/27/2021 08/27/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/27/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Underslab Plumbing Inspection - Residential Passed 8/27/2021 8/27/2021 08/27/2021
Misc
Corrective Action Required
08/27/2021
POST ADDRESS
Water Service Inspection - R Passed 9/9/2021 9/9/2021 09/09/2021
Sewer Service Inspection - R Passed 9/9/2021 09/09/2021
Erosion Control Inspection Residential Failed 10/15/2021 10/15/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/27/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/15/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - CLEAN STREET -
All Rough Inspection - Residential Failed 11/11/2021 11/11/2021 11/11/2021
Miscellaneous Correction
Corrective Action Required
11/11/2021
INSPECTION DENIED NO ADDRESS POSTED WE WILL NOT PERFORM SEPARATE PORTAL FRAME INSPECTIONS - THESE WILL BE COMPLETEDAT THE ALL ROUGH 1ST INSPECTION
Electrical Service Inspection Passed 3/15/2022 3/15/2022 03/15/2022
All Rough Inspection - Residential Failed 3/15/2022 3/15/2022 03/15/2022
Miscellaneous Correction
Resolved
03/15/2022
Misc
Corrective Action Required
03/15/2022
- Nail pattern on portal frame to detail on plans - Nail exterior corner to code north east - Fire block chase second floor fake chimney - Fire block penetration second floor toilet - Complete bathrooms fan ductwork through out - Terminate DWV vent bathroom by bedroom 3 - Snow block bedroom 3 - Complete DWV above garage through roof - Complete B-vent second floor through roof - Joist hangers at basement joist next to B-vent - Missing joist hangers living room front on house
All Rough Inspection - Residential Failed 3/23/2022 3/23/2022 03/23/2022
Misc
Corrective Action Required
03/15/2022
- Fire block penetration second floor toilet - Adress I-beam 2" out of pocket north side basement OK to insulate
Erosion Control Inspection Residential Failed 3/23/2022 03/23/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/15/2021
- Remove debris from street corner - repair silt fence
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/23/2022
All Rough Inspection - Residential Failed 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/23/2022
- Fire block penetration second floor toilet supply line and penetration - Adress I-beam 2" out of pocket north side basement 3/29/22 nothing changed 2 x6 under I-beam in basement need’s to be cut square with beam to distribute the load and anchored to wall with anchor bolts at top middle and bottom OK to insulate
Erosion Control Inspection Residential Failed 3/30/2022 03/30/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/23/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. REMOVE DEBRIS FROM STREET AND PROVIDE ADEQUATE EROSION CONTROL ON STREET CORNER OF LOT.
All Rough Inspection - Residential Failed 4/1/2022 4/1/2022 04/01/2022
Misc
Resolved
04/01/2022
All Rough Inspection - Residential Passed 04/01/2022
Erosion Control Inspection Residential Failed 4/1/2022 04/29/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
04/01/2022
Misc
Corrective Action Required
04/29/2022
Silt fence on sw side of lot is not intact and large amount of mud has piled into the street. Needs corrected and street cleaned. 4/29/22 ES
Erosion Control Inspection Residential Failed 05/24/2022
Misc
Corrective Action Required
04/29/2022
Silt fence on sw side of lot is not intact and large amount of mud has piled into the street. Needs corrected and street cleaned. 4/29/22 ES
Misc
Corrective Action Required
05/24/2022
All erosion control needs attention. West side there is no erosion control towards north end of property allowing mud/silt to drain directly into street. Silt socks on SW corner are inadequate for stopping mud/silt from covering ADA ramp or entering roadway. Please correct as this SW corner has previously been addressed and measures are not enough to prevent further issues. 5/24/22 ES
Gas Service Inspection - Residential Failed 3/15/2022 07/18/2022
Misc
Corrective Action Required
07/18/2022
- no presure on gauge - bonding clamp not connected
All Rough Inspection - Residential Failed 7/18/2022 07/18/2022
Misc
Informational
07/18/2022
Basement finnish added
Misc
Corrective Action Required
07/18/2022
- fire blocking not complete - strap DWV near eletrical panel - frame out under the stairs
Gas Service Inspection - Residential Passed 07/19/2022
Misc
Resolved
07/19/2022
Sidewalk Inspection Partial 7/20/2022 7/20/2022 07/20/2022
Misc
Informational
07/20/2022
West side of house had sidewalk framed up with aggregate in place and compacted. 7/20/22 ES
Sidewalk Inspection Partial 7/29/2022 7/29/2022 08/01/2022
Misc
Informational
07/20/2022
West side of house had sidewalk framed up with aggregate in place and compacted. 7/20/22 ES West side of house sidewalk meets LS and ADA specs. 8/1/22 ES
Sidewalk Inspection Partial 8/17/2022 8/17/2022 08/17/2022
Misc
Informational
08/01/2022
West side of house had sidewalk framed up with aggregate in place and compacted. 7/20/22 ES West side of house sidewalk meets LS and ADA specs. 8/1/22 ES South side of house sidewalk framed up with aggregate in and compacted. 8/17/22 ES
Sidewalk Inspection Passed 8/26/2022 8/26/2022 09/08/2022
Misc
Informational
08/17/2022
West side of house had sidewalk framed up with aggregate in place and compacted. 7/20/22 ES West side of house sidewalk meets LS and ADA specs. 8/1/22 ES South side of house sidewalk framed up with aggregate in and compacted. 8/17/22 ES South sidewalk meets LS and ADA spec along with remainder of sidewalk. 9/8/22 ES
Erosion Control Inspection Residential Passed 9/14/2022 09/14/2022
Misc
Resolved
09/14/2022
Misc
Resolved
09/14/2022
All Rough Inspection - Residential Passed 7/19/2022 7/19/2022 09/14/2022
Misc
Resolved
09/14/2022
Misc
Resolved
09/14/2022
Plot Plan Inspection Passed 9/14/2022 09/14/2022
Occupancy Inspection - Codes Residential Failed 9/14/2022 9/14/2022 09/14/2022
Miscellaneous Correction
Corrective Action Required
09/14/2022
- Complete latch on garage entry door - Outlet dead north bedroom at bathroom counter - Provide ani siphon device - Add gravel to Egress window well - Label all non gfci outlets - Humidifier not connected to water - Provide handrail for basement stairs - Step at sliding door to patio has more than 3/8” variance - Sump discharge minimum of 36” away from foundation - Provide splash blocks - Address shall be contrasting in color - Top step on front entry out of compliance - Obtain an irrigation permit and submit a back flow certification
Occupancy Inspection - Codes Residential Ready for Temp CO 9/16/2022 9/16/2022 09/16/2022
Miscellaneous Correction
Corrective Action Required
09/14/2022
- Provide splash blocks - Obtain an irrigation permit and submit a back flow certification
Occupancy Inspection - Codes Residential Temporary C of O 9/16/2022 09/16/2022
Miscellaneous Correction
Corrective Action Required
09/16/2022
- Provide splash blocks - Obtain an irrigation permit and submit a back flow certification TCO Expiration 10/16/22
Occupancy Inspection - Codes Residential Ready for Temp CO 2/29/2024 02/29/2024
Miscellaneous Correction
Corrective Action Required
09/16/2022
- Pay back fees for each 30 days of TCO - submit request form
Occupancy Inspection - Codes Residential Ready for Temp CO 4/30/2024 04/30/2024
Miscellaneous Correction
Corrective Action Required
02/29/2024
- Provide splash blocks - Obtain an irrigation permit and submit a back flow certification - Pay back fees for each 30 days of TCO - submit request form
Occupancy Inspection - Codes Residential Failed 12/9/2025 12/09/2025
Miscellaneous Correction
Corrective Action Required
04/30/2024
- Provide splash blocks - Obtain an irrigation permit and submit a back flow certification - Pay back fees for each 30 days of TCO - submit request form
Documents & Images
Date Uploaded File Type Document Name
05/24/2021 1033 SW Redbuck Cir_ Excise Tax Application
05/24/2021 1033 SW Redbuck Cir_ Permit Application
05/25/2021 Permit Codes Residential Plan Review
05/26/2021 Plot Plan Approved Plot Plan
06/09/2021 Permit Codes Residential Plan Review
06/10/2021 Permit DS Building Permit
06/10/2021 Receipt Receipt for transaction: 2021-004274
08/02/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
09/09/2021 Letter INSPECTION SUMMARY
09/09/2021 Letter INSPECTION SUMMARY
10/15/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
07/12/2022 1033 SW Redbuck Scope of Work
07/15/2022 Approved Plans APPROVED PLANS
07/15/2022 Receipt Receipt for transaction:2022-005816
07/18/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/14/2022 Letter INSPECTION SUMMARY
09/14/2022 Letter INSPECTION SUMMARY
09/14/2022 Letter INSPECTION SUMMARY
09/16/2022 Receipt Receipt for transaction:2022-007591
09/16/2022 Letter Codes Temporary Certificate of Occupancy
02/03/2023 Letter Codes 140 Day Letter
03/14/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/14/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/14/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/14/2024 Receipt Receipt for transaction:2024-001605
04/30/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter Codes 140 Day Letter
12/09/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home