Permit Application Status

PRRES20212682


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212682
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
05/24/2021
06/01/2021
11/22/2021
01/31/2024
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE ELECTRICAL CONSTRUCTION, Address:3710 ROBINSON PIKE RD, Phone:(816) 761-0200  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Right of Way Permit Fee $80.00 $80.00 Paid 06/01/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/01/2021
8331507-Sewer Connection Fee $480.00 $480.00 Paid 06/01/2021
Valuation Fee New Single Family $1,319.23 $1,319.23 Paid 06/01/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 06/01/2021
Water Meter Fee $455.54 $455.54 Paid 06/01/2021
8331504-EFHB Middle Big Creek, Full $535.68 $535.68 Paid 06/01/2021
Temporary Occupancy Fee $50.00 $50.00 Paid 07/21/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/12/2021 (11:30) 7/12/2021 07/12/2021
Erosion Control Inspection Residential Failed 9/10/2021 9/10/2021 09/10/2021
Misc
Corrective Action Required
09/10/2021
MAINTAIN EROSION CONTROL ON LOT. SILT FENCE REQUIRES CONTINUOUS MAINTENANCE. CLEAN ALL MUD AND GRAVEL THAT HAS WASHED OVER SILT FENCE ONTO STREET AND WALK. CLEAN MUD BUILDUP AT FRONT OF GUTTER BUDDY AT STORM INLET FRONT OF LOT
Underslab Plumbing Inspection - Residential Passed 9/24/2021 9/24/2021 09/24/2021
Sewer Service Inspection - R Passed 1/11/2022 (2:00) 1/11/2022 01/11/2022
Water Service Inspection - R Passed 1/13/2022 (11:30) 1/13/2022 01/13/2022
Erosion Control Inspection Residential Failed 1/13/2022 1/13/2022 01/13/2022
Misc
Resolved
01/13/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/13/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 3/3/2022 03/03/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/13/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Gas Service Inspection - Residential Failed 3/3/2022 3/3/2022 03/03/2022
Misc
Corrective Action Required
03/03/2022
-INSPECTION DENIED DUE TO LACK OF EROSION CONTROL
Gas Service Inspection - Residential Failed 3/10/2022 3/10/2022 03/10/2022
Misc
Corrective Action Required
03/03/2022
-Gas line bond need to be placed on steel line before first connection of CSST gas line **PRESSURE OK**
Electrical Service Inspection Passed 3/10/2022 3/10/2022 03/10/2022
All Rough Inspection - Residential Failed 3/10/2022 3/10/2022 03/10/2022
Misc
Corrective Action Required
03/10/2022
-Garage portal PFH covered, unable to inspect nailing pattern of sheathing and hold down straps embedded in concrete -Anchor bolt required garage PFH, 5/8” bolt/nut w/ 2”x2”x3/16” washer -anchor bolts to be in middle third of plate -less than 24” lap at top plate break at steel beam west side garage -Fireblock HVAC chase at garage -solid block all sheathing breaks -add studs shoes kitchen exterior wall DWV -add protection plate at bottom plate pex kitchen fridge -CS-PF portal bracing design per plans s at dining room see detail in plans A4 -rock screw pattern inspection will need to be performed after given approval of wall bracing design GB at garage, great room, dining room, foyer,bed#2, bed#3, 2nd floor hall,master bed, master closet; min 1/2” rock screwed 7” oc edges and wall, both faces of wall, see page 5 braced walls -Have engineer address rafters landing on blocks above the ceiling joist, ceiling joist to rafter to top plate connection not present -min 24” offset between plate breaks- see 2nd floor west bath -provide full bearing support for ridge end bed#4 -provide joist hanger at attic access 2nd floor -add joist hanger dbl 2x10 ceiling box master bedroom -terminate NM to box master bed exterior wall -install basement egress window -address 2x10 joist bored less than 2” from end of joist for sump pump discharge line at basement -outlet receptacle required at unfinished basement (ensure within 25’ of furnace) -Gas line bond need to be placed on steel line before first connection of CSST gas line -Nail all exterior sheathing per plans
Erosion Control Inspection Residential Failed 3/30/2022 03/30/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/03/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/30/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. MAINTAIN GRAVEL FILTER CLEAN STREET
Gas Service Inspection - Residential Passed 4/7/2022 4/7/2022 04/07/2022
Misc
Resolved
04/07/2022
All Rough Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
03/10/2022
-rock screw pattern inspection will need to be performed after given approval of wall bracing design GB at garage, great room, dining room, foyer,bed#2, bed#3, 2nd floor hall,master bed, master closet; min 1/2” rock screwed 7” oc edges and wall, both faces of wall, see page 5 braced walls **OK TO INSULATE AND ROCK**
All Rough Inspection - Residential Passed 4/21/2022 4/21/2022 04/21/2022
Misc
Resolved
04/21/2022
Erosion Control Inspection Residential Failed 4/21/2022 4/21/2022 04/21/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/21/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
04/21/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. MAINTAIN GRAVEL FILTER CLEAN STREET
Misc
Corrective Action Required
04/21/2022
-MAINTAIN GRAVEL FILTER ON DRIVE
Erosion Control Inspection Residential Failed 4/21/2022 4/21/2022 04/21/2022
Misc
Corrective Action Required
04/21/2022
-MAINTAIN GRAVEL FILTER ON DRIVE
Driveway Inspection Partial 6/14/2022 6/14/2022 06/14/2022
Misc
Informational
06/14/2022
On 6.14.2022 I performed a driveway inspection and pass the subgrade to pour concrete.
Piers/Caissons Inspection - Residential Passed 07/20/2022
Misc
Corrective Action Required
07/20/2022
APPROVED PER CHAD M STREETER 11/18/21
Erosion Control Inspection Residential Passed 7/20/2022 7/20/2022 07/20/2022
Misc
Resolved
07/20/2022
-MAINTAIN GRAVEL FILTER ON DRIVE
Occupancy Inspection - Codes Residential Failed 7/20/2022 7/20/2022 07/20/2022
Misc
Corrective Action Required
07/20/2022
-Obtain lawn irrigation system permit -raise water meter lid to grade, maintain 14"-18"clearance from top of meter to top of lid -Final driveway inspection required, contact development services to schedule -submit as graded plot plan for review and approval -gutters and downspouts -splash blocks -outlet covers, GFCI protection outlets at garage -provide security screws at back door -provide ladder at basement egress well
Occupancy Inspection - Codes Residential Ready for Temp CO 7/21/2022 7/21/2022 07/21/2022
Misc
Corrective Action Required
07/20/2022
-Obtain lawn irrigation system permit -raise water meter lid to grade, maintain 14"-18"clearance from top of meter to top of lid -Final driveway inspection required, contact development services to schedule -submit as graded plot plan for review and approval -gutters and downspouts -splash blocks
Occupancy Inspection - Codes Residential Temporary C of O 07/21/2022
Misc
Corrective Action Required
07/21/2022
-Obtain lawn irrigation system permit -raise water meter lid to grade, maintain 14"-18"clearance from top of meter to top of lid -Final driveway inspection required, contact development services to schedule -submit as graded plot plan for review and approval -gutters and downspouts -splash blocks
Driveway Inspection Passed 11/2/2022 11/2/2022 11/02/2022
Misc
Informational
06/14/2022
On 6.14.2022 I performed a driveway inspection and pass the subgrade to pour concrete. 11-2-22 RH. Meets LS and ADA specification.
Occupancy Inspection - Codes Residential Failed 9/20/2023 9/20/2023 09/20/2023
Misc
Partial Correction
09/20/2023
-Obtain lawn irrigation system permit
Plot Plan Inspection Passed 9/22/2023 09/22/2023
MISC
Informational
09/22/2023
As built plot plan passed. Will reevaluate after sod is installed.
Erosion Control Inspection Residential Failed 9/22/2023 09/22/2023
Miscellaneous Correction
Corrective Action Required
09/22/2023
Backyard sod removed to redone plot plan.
Occupancy Inspection - Codes Residential Full C of O 1/31/2024 1/31/2024 01/31/2024
Misc
Resolved
01/31/2024
-Obtain lawn irrigation system permit
Erosion Control Inspection Residential Passed 1/31/2024 01/31/2024
Miscellaneous Correction
Resolved
01/31/2024
Backyard sod removed to redone plot plan.
Documents & Images
Date Uploaded File Type Document Name
05/24/2021 Application Form APPLICATION
05/24/2021 exciseapplication 1841 sw sage canyon
05/24/2021 Application Form excise tax
05/25/2021 LOT 155 FINAL
05/25/2021 KH-6113 (LOT 155 NAPA)
05/26/2021 Approved Plans APPROVED PLANS
05/26/2021 Permit Codes Residential Plan Review
05/26/2021 Plot Plan APPROVED PLOT PLAN
06/01/2021 Permit Codes Residential Plan Review
06/01/2021 Permit DS Building Permit
06/01/2021 Receipt Receipt for transaction:2021-003707
07/12/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
03/03/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
04/05/2022 1841 SW Sage - Lot 155
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
07/15/2022 1841 SW Sage Canyon Rd_DECK PIER INSP_2021-11-18 (002)
07/20/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
07/20/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Receipt Receipt for transaction:2022-005977
07/21/2022 Letter Codes Temporary Certificate of Occupancy
11/02/2022 Letter INSPECTION SUMMARY
09/19/2023 LOT 155 ASBUILT 8-31-23 (1)
09/20/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter Codes Residential Plan Review
09/21/2023 Plot Plan approved as graded plot plan
09/22/2023 Letter INSPECTION SUMMARY
09/22/2023 Letter INSPECTION SUMMARY
01/31/2024 Letter Codes Final Certificate of Occupancy
01/31/2024 Letter Field Certificate of Occupancy
01/31/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: