Permit Application Status

PRRES20212610


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212610
Building Permit - Residential
Certificate of Occupancy
MONTICELLO HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - ENGINEERED FLOOR SYSTEM - PARTIAL FINISHED BASEMENT AND UNFINISHED BASEMENT -
05/19/2021
05/31/2021
04/26/2022
Locations
Contacts
MONTICELLO HOMES INC, Address:PO BOX 7005, Phone:(816) 478-4740  
MONTICELLO HOMES INC, Address:623 NE LONE HILL DR  
Andrea Peterson, Address:PO Box 7005  
ANDREAPETERSON@COMCAST.NET  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
HATHEWAY ELECTRIC LLC, Address:3125 SW PRYOR RD, Phone:(660) 232-2419  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $660.00 $660.00 Paid 05/31/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/31/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 05/31/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/31/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/31/2021
9110078-Valuation Fee New Single Family $1,600.44 $1,600.44 Paid 05/31/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/16/2021 7/16/2021 07/16/2021
Sewer Service Inspection - R Passed 8/13/2021 (1:00) 8/13/2021 08/13/2021
Water Service Inspection - R Partial 8/13/2021 (1:00) 8/13/2021 08/13/2021
Water Service Inspection - R Passed 8/17/2021 (11:00) 8/17/2021 08/17/2021
Erosion Control Inspection Residential Failed 8/23/2021 08/23/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/23/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 8/23/2021 8/23/2021 08/23/2021
Misc
Corrective Action Required
08/23/2021
-INSPECTION DENIED. REPAIR EROSION CONTROL ALONG THE STREET
Underslab Plumbing Inspection - Residential Passed 8/25/2021 8/25/2021 08/25/2021
Misc
Resolved
08/25/2021
-INSPECTION DENIED. REPAIR EROSION CONTROL ALONG THE STREET
Erosion Control Inspection Residential Passed 8/25/2021 08/25/2021
Misc
Informational
08/25/2021
MAINTAIN EROSION CONTROL
Piers/Caissons Inspection - Residential Passed 12/10/2021
Informational
12/10/2021
PIER INSPECTED AND APPROVED BY ENGINEER
Gas Service Inspection - Residential Passed 12/17/2021 12/17/2021 12/17/2021
Electrical Service Inspection Passed 12/17/2021 12/17/2021 12/17/2021
All Rough Inspection - Residential Failed 12/17/2021 12/17/2021 12/17/2021
Misc
Corrective Action Required
12/17/2021
-Complete installing trim at rear of house -Nail zip board to sill plates at front of house per code -Nail garage PFH wall sheathing to stud @3” oc -Install stud shoe at over bored stud at service panel -Strap top plate at garage/entry wall intersection -Fb duct/b-vent chase from joist space -Vent all bath fans -Protect plumbing at bedroom 4 top wall plate -Provide 5 stud support for I beam at rear dining wall corner and solid block below -Fully nail lvl hanger at dining rm I beam connection -Install joist hangers at lvl connections above top stair landing (stair to basement) -Strap top plates lapped less than 24” outside study room -Secure deck fireplace to framing -Have engineer address TJI joist above pantry. Bored holes too close to the bottom flange and one joist with cut bottom flange -Install joist hangers above pantry -Provide document for fireplace. Check min clearance above fireplace. Provide min 1” clearance from flue to combustible -Complete electrical at foyer -Protect wiring at laundry -Install hangers at connections to T1 girder truss -Strap T1 girder using devices rated for uplifts (635 lbs @ pt 22; 1962 lbs @ 17; 529 lbs @ 11) -Strap F1 girder truss using devices rated for uplifts per detail (843 lbs and 800 lbs at ends) -Protect water lines at master shower -Fb dead space at master shower from roof -Install lvl beam below foyer load bearing wall. Have too many things in the way. Maybe get the engineer to take a look at this -Bond gas piping -Complete windows installation in basement **OK TO INSULATE
All Rough Inspection - Residential Failed 12/29/2021 12/29/2021 12/29/2021
Misc
Corrective Action Required
12/17/2021
-Install stud shoe at over bored stud at service panel -Fb duct/b-vent chase from joist space -Provide 5 stud support for I beam at rear dining wall corner and solid block below -Have engineer address TJI joist above pantry. Bored holes too close to the bottom flange and one joist with cut bottom flange -Complete electrical at foyer -Protect wiring at laundry -Strap T1 girder using devices rated for uplifts (635 lbs @ pt 22; 1962 lbs @ 17; 529 lbs @ 11) **no -Strap F1 girder truss using devices rated for uplifts per detail (843 lbs and 800 lbs at ends) **not done -Install lvl beam below foyer load bearing wall. Have too many things in the way. Maybe get the engineer to take a look at this **Complete all trades at foyer and pantry/kitchen
All Rough Inspection - Residential Failed 1/4/2022 1/4/2022 01/04/2022
Misc
Corrective Action Required
12/29/2021
-Install stud shoe at over bored stud at service panel -Fb duct/b-vent chase from joist space -Have engineer address TJI joist above pantry. Bored holes too close to the bottom flange and one joist with cut bottom flange -Complete electrical at foyer -Strap T1 girder using devices rated for uplifts (635 lbs @ pt 22; 1962 lbs @ 17; 529 lbs @ 11) **no -Strap F1 girder truss using devices rated for uplifts per detail (843 lbs and 800 lbs at ends) **not done **Complete all trades at foyer and pantry/kitchen
All Rough Inspection - Residential Passed 1/5/2022 1/5/2022 01/05/2022
Misc
Informational
01/05/2022
Thanks Andrea!
Driveway Inspection Partial 4/4/2022 4/4/2022 04/04/2022
Misc
Informational
04/04/2022
4-4-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 4/8/2022 4/8/2022 04/08/2022
Misc
Informational
04/04/2022
4-4-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
04/08/2022
4-8-22 AN driveway looks good and has expansion joints at curb and right of way. Meets Ada specs
Occupancy Inspection - Codes Residential Full C of O 4/26/2022 4/26/2022 04/26/2022
Documents & Images
Date Uploaded File Type Document Name
05/19/2021 Lot 323 Park Ridge - Residental Permit Application_1
05/19/2021 Lot 323 Park Ridge - License_Tax_Application
05/20/2021 Permit Codes Residential Plan Review
05/31/2021 Permit DS Building Permit
05/31/2021 Receipt Receipt for transaction:2021-003650
08/13/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/17/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
08/25/2021 Letter INSPECTION SUMMARY
08/25/2021 Letter INSPECTION SUMMARY
10/15/2021 Approved Plans APPROVED UPDATED PLANS
10/15/2021 Plot Plan APPROVED PLOT PLAN
12/09/2021 2021_10_22_Post Pour Deck Pier_Gilsdorf Lot 323
12/10/2021 Letter INSPECTION SUMMARY
12/17/2021 Approved Plans APPROVED TRUSS PACKAGE
12/17/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
12/29/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/04/2022 SDWC15600 Hold down for Girder F1
01/04/2022 REV 12-22 Lot 323 Park Ridge 2nd Floor I-Joist Layout GR
01/04/2022 REV 12-22 BCReport20211222_103154
01/05/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter Field Certificate of Occupancy
04/26/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home