Permit Application Status

PRRES20212568


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212568
Building Permit - Residential
Certificate of Occupancy
WINTERSET 6 LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK DEFERRED ROOF TRUSSES
05/19/2021
05/26/2021
11/15/2021
09/08/2022
Locations
Contacts
ROESER HOMES LLC, Address:11415 STRANG LINE RD, Phone:(913) 220-7477  
MATT@ROESERHOMES.COM  
WINTERSET 6 LLC, Address:2602 N STADIUM BLVD  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ELECTRICAL INVESTMENTS, Address:8014 REEDER ST, Phone:(816) 210-1597  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,649.82 $1,649.82 Paid 05/26/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/26/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 05/26/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 05/26/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/26/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/26/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/2/2021 (1:00) 8/2/2021 08/02/2021
Underslab Plumbing Inspection - Residential Passed 9/10/2021 9/10/2021 09/10/2021
Sewer Service Inspection - R Partial 11/19/2021 (4:00) 11/19/2021 11/19/2021
Misc
Informational
11/19/2021
inspected from foundation 3ft away from main sewer stub
Water Service Inspection - R Passed 11/22/2021 (10:00) 11/22/2021 11/22/2021
Sewer Service Inspection - R Passed 11/22/2021 (10:00) 11/22/2021 11/22/2021
Misc
Resolved
11/22/2021
inspected from foundation 3ft away from main sewer stub
Erosion Control Inspection Residential Failed 2/9/2022 02/09/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 2/11/2022 02/11/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 2/11 nothing done
Gas Service Inspection - Residential Failed 3/8/2022 3/8/2022 03/08/2022
Misc
Corrective Action Required
03/08/2022
No pressure on gauge
Electrical Service Inspection Passed 3/8/2022 3/8/2022 03/08/2022
All Rough Inspection - Residential Failed 3/8/2022 3/8/2022 03/08/2022
Misc
Corrective Action Required
03/08/2022
Not ready, no fire blocking done yet. Need to address erosion control
Erosion Control Inspection Residential Failed 3/8/2022 03/08/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/11/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Passed 3/9/2022 03/09/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
03/09/2022
All Rough Inspection - Residential Failed 3/9/2022 03/09/2022
Misc
Resolved
03/09/2022
Not ready, no fire blocking done yet.
Miscellaneous Correction
Corrective Action Required
03/09/2022
- No fire blocking anywhere no further inspections until this is complete - No sliding door main floor - Boca plate DWV floor bathroom at garage - Nail all exterior intersecting corners to code - Address 2x6” studs cut and not full length either side of windows in hearth room - Provide joist hanger on double at bottom of stairs basement - Provide joist hanger at cantilever joist at exterior wall straight across from stairs basement - Nail hanger at double joist 6’ out from bottom of stairs - Missing stud basement stairs riser - Address loose snow blocking in master suite - Gap in top plate master shower - Provide triple truss hanger for girder to girder connection at master bathroom A1-W6 - Provide window front middle bedroom - Complete vent ductwork bathroom second floor middle - Strap top plate second floor middle bedroom left of window - Truss E7 not nailed to bracket second floor sitting room
All Rough Inspection - Residential Failed 3/30/2022 3/30/2022 03/30/2022
Miscellaneous Correction
Corrective Action Required
03/09/2022
- No sliding door main floor - Nail all exterior intersecting corners to code 2 nails at 12” oc -- Address 2x6” jack studs cut and not full length either side of windows in hearth room - -Gap in top plate master shower - -Provide window front middle bedroom 3/30/22 New items - fire block plenum space at study/ living room chase - Fire block HVAC chase at atrium - Fire block end of chase east bathroom top - Nail exterior siding 2 floor south east closet - Fire block gaps in blocking 2 floor stairs landing above south bedroom doorway - Fire block from joist space chase living room at fire place - Tape seams in return air pan out at bathroom/ and HVAC garage wall - Fire block floor penetration for steel columns first floor
Gas Service Inspection - Residential Failed 3/30/2022 3/30/2022 03/30/2022
Misc
Corrective Action Required
03/08/2022
No pressure on gauge 3/30/22 no pressure on gauge.
All Rough Inspection - Residential Failed 4/1/2022 4/1/2022 04/01/2022
Miscellaneous Correction
Corrective Action Required
03/30/2022
- No sliding door main floor - Nail all exterior intersecting corners to code 2 nails at 12” oc -- - -Gap in top plate master shower (now needs strap) - -Provide window front middle bedroom 3/30/22 New items - fire block plenum space at study/ living room chase - Fire block HVAC chase at atrium - Fire block end of chase east bathroom top
Gas Service Inspection - Residential Failed 4/1/2022 4/1/2022 04/01/2022
Misc
Corrective Action Required
03/30/2022
No pressure on gauge 3/30/22 no pressure on gauge. 4/1/22 no pressure on gauge
All Rough Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Miscellaneous Correction
Corrective Action Required
04/01/2022
- -Provide window front middle bedroom OK TO INSULATE AND ROCK
Gas Service Inspection - Residential Passed 4/7/2022 4/7/2022 04/07/2022
Misc
Resolved
04/07/2022
Driveway Inspection Partial 5/10/2022 5/10/2022 05/10/2022
Misc
Informational
05/10/2022
5-10-22 AN forms are in place and aggregate is present and compacted. No sidewalk
Driveway Inspection Passed 5/16/2022 5/16/2022 05/17/2022
Misc
Informational
05/10/2022
5-10-22 AN forms are in place and aggregate is present and compacted. No sidewalk
Misc
Informational
05/17/2022
Driveway meets LS specs. 5/17/22 ES
Erosion Control Inspection Residential Failed 06/08/2022
Misc
Corrective Action Required
06/08/2022
Erosion control measures ineffective, need to be addressed to prevent silt and mud from entering roadway. 5/8/22 ES
Erosion Control Inspection Residential Passed 08/10/2022
Misc
Resolved
08/10/2022
All Rough Inspection - Residential Passed 08/10/2022
Miscellaneous Correction
Resolved
08/10/2022
Occupancy Inspection - Codes Residential Failed 8/10/2022 08/10/2022
Misc
Corrective Action Required
08/10/2022
• obtain irrigation permit and provide back flow certification • Pay all fees • Final grading and sod • Provide gutters and down spouts • Splash blocks • Ladder for egress window • Attach A/C electrical whip 12” from disconnect • Seal top of a/c disconnect • Seal top of meter can • Seal all exterior penetrations • Provide spark rings kitchen counter outlets • Cover missing electrical outlet kitchen • No hardware at kitchen sliding door • Kitchen vent not complete • Outlet in upstairs laundry must be gfci protected • Switch cover missing master bedroom • Install water heater • Anchor steel columns in basement • Provide water pressure regulator • Provide water back flow preventer at spigot at main • Add dedicated non gfci outlet for sump pump • Lock outs at electrical panel
Plot Plan Inspection Passed 09/08/2022
Occupancy Inspection - Codes Residential Full C of O 9/8/2022 9/8/2022 09/08/2022
Misc
Resolved
09/08/2022
Documents & Images
Date Uploaded File Type Document Name
05/19/2021 Application Form Permit Application
05/19/2021 Application Form License Tax Form
05/19/2021 Final Plot plan - Lot 1484 WV
05/19/2021 Permit Codes Residential Plan Review
05/26/2021 Final Plot plan - Lot 1484 WV
05/26/2021 Approved Plans Approved Drawings
05/26/2021 Plot Plan Approved Plot Plan
05/26/2021 Permit Codes Residential Plan Review
05/26/2021 Permit DS Building Permit
05/26/2021 Receipt Receipt for transaction:2021-003534
07/26/2021 Approved Plans Approved Truss Package
07/26/2021 Approved Plans Approved Truss Layout
08/02/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
11/22/2021 Letter INSPECTION SUMMARY
11/22/2021 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter Codes Final Certificate of Occupancy
09/08/2022 Letter Field Certificate of Occupancy
09/08/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home