Permit Application Status

PRRES20212483


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212483
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO
05/14/2021
05/18/2021
11/13/2021
08/16/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DREW@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,512.93 $1,512.93 Paid 05/18/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/18/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 05/18/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 05/18/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/18/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/18/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/15/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/15/2022
9110078-Additional Permit Fee $101.10 $101.10 Paid 04/29/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/14/2021 06/14/2021
Misc
Informational
06/14/2021
3RD PARTY FOOTING BY COLBY SHAW @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED CENTER OF REAR GARAGE WALL
Underslab Plumbing Inspection - Residential Passed 7/19/2021 7/19/2021 07/19/2021
Sewer Service Inspection - R Passed 7/27/2021 (9:30) 7/27/2021 07/27/2021
Erosion Control Inspection Residential Failed 8/2/2021 08/02/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/02/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - MAINGTAIN GUTTER BUDDY REMOVE SEDIMENT BUILD UP - - CLEAN STREET -
Water Service Inspection - R Passed 8/2/2021 (10:30) 8/2/2021 08/02/2021
All Rough Inspection - Residential Failed 9/29/2021 9/29/2021 09/29/2021
Miscellaneous Correction
Corrective Action Required
09/29/2021
PFH GARAGE PORTAL FRAME ONLY OK TO COVER
Misc
Corrective Action Required
12/13/2021
PLANS ON SITE MISSING 2ND STORY FLOOR PLAN NO INSPECTION PROVIDE FULL SET OF CITY APPROVED PLANS
Driveway Inspection Partial 11/23/2021 11/23/2021
Misc
Informational
11/23/2021
Driveway was framed up with aggregate in and compacted.11/23 ES
Driveway Inspection Passed 12/3/2021 12/3/2021 12/03/2021
Misc
Informational
11/23/2021
Driveway was framed up with aggregate in and compacted.11/23 ES
Misc
Informational
12/03/2021
Driveway meets LS spec. RP 12-3-21
Electrical Service Inspection Passed 12/13/2021 12/13/2021 12/13/2021
Gas Service Inspection - Residential Failed 12/13/2021 12/13/2021 12/13/2021
Miscellaneous Correction
Corrective Action Required
12/13/2021
PROVIDE MINIMUM 10 PSI FOR 15 MINUTES
Erosion Control Inspection Residential Failed 12/13/2021 12/13/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/02/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - MAINGTAIN GUTTER BUDDY REMOVE SEDIMENT BUILD UP - - CLEAN STREET -
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
12/13/2021
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Failed 12/13/2021 12/13/2021 12/13/2021
Miscellaneous Correction
Corrective Action Required
09/29/2021
PFH GARAGE PORTAL FRAME ONLY OK TO COVER
Misc
Corrective Action Required
12/13/2021
PLANS ON SITE MISSING 2ND STORY FLOOR PLAN NO INSPECTION PROVIDE FULL SET OF CITY APPROVED PLANS
Gas Service Inspection - Residential Not Ready 12/15/2021 12/15/2021 12/15/2021
Miscellaneous Correction
Corrective Action Required
12/13/2021
PROVIDE MINIMUM 10 PSI FOR 15 MINUTES
Erosion Control Inspection Residential Failed 12/15/2021 12/15/2021 12/15/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/13/2021
*12-15-21 -CORRECTIONS REQUIRED WITHIN 2 BUSINESS DAYS- -NO FURTHER INSPECTIONS UNTIL IN COMPLIANCE - MAINTAIN GUTTER BUDDY REMOVE SEDIMENT BUILD UP, CLEAN DEBRIS SPILLED OVER CURB LINE, PROTECT STORM INLET, REMOVE PORTA JOHN FROM TOP OF INLET
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
12/15/2021
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Failed 12/15/2021 12/15/2021 12/15/2021
Miscellaneous Correction
Resolved
12/15/2021
PFH GARAGE PORTAL FRAME ONLY OK TO COVER
Misc
Corrective Action Required
12/13/2021
*12-15-21 -CORRECTIONS TO EROSION CONTROL REQUIRED WITHIN 2 BUSINESS DAYS- -NO FURTHER INSPECTIONS UNTIL IN COMPLIANCE - MAINTAIN GUTTER BUDDY REMOVE SEDIMENT BUILD UP, CLEAN DEBRIS SPILLED OVER CURB LINE, PROTECT STORM INLET, REMOVE PORTA JOHN FROM TOP OF INLET -Expose and provide uplift connections at covered porch trusses -Nail off exterior wall sheathing at sill -Provide anchor bolt single garage at return panel and end of wall by furout -Seal fire blocking furout top around 3” in single car bay -FB soffit line, rim joist, and furout for insulation at mechanical in 2 car bay -Seal fire block top of ductwork.pantry -Provide 2 nails at all locations on LIB bracing straps throughout -Provide joist hangers at joist to header location in mechanical chase -Provide 1.5” support or proper hanger for joist to LVL connection at owner’s entry alcove -Seal fire blocking soffit bathroom near flex room -Provide hanger for (4) LVL beam above owner’s entry -Nail hangers in flex room and flex bathroom -Seal bottom plate penetration at flex bath -Nail all exterior corners and intersecting wall studs per code -Support (4) lvls above refrigerator -Provide hanger at (3) 2x10 by refrigerator -Provide protection plate at 3” waste pipe at ceiling living room -Provide (5) studs under (4) lvls both in kitchen and flex room -Seal penetration at fur out between dining and living room -Address walls not connected where cut out for ductwork in living room furout -Provide 3 2x10s joist living room per plan -Fire block chase in corner by fireplace-seal gaps -Provide 3 2x6 at landing for i beam per plan -Complete through bolts on I beam at dining room -Secure bottom of steel post at stairway -Provide LIBs per plan -Provide LUS 24 hangers per plan girder truss C 01 -Provide TJC37 hanger per truss plans second floor -Provide Lus24 hangers master bathroom per truss plans -Complete vent ductwork upstairs -Seal floor penetration second floor fireplace -Fire block stud bay stairway landing next to window -Seal penetration second floor laundry by tub -Fire block dead space top master bathroom and return air and all chases -Steel column Pad E calls for a 3,5” not 3” -Provide (4) studs at all GT bearing locations -Provide hangers on 5’ joist basement near stairs -Provide double 2x10 joist by furnace per plan -Provide protection plate at sump discharge line in stair landing -Fire block penetration basement corner at garage, plumbing -Anchor bolts schedule 40 columns -Flash and install missing windows
Erosion Control Inspection Residential Partial 12/20/2021 12/20/2021 12/20/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/20/2021
*12-15-21 -CORRECTIONS REQUIRED WITHIN 2 BUSINESS DAYS- -NO FURTHER INSPECTIONS UNTIL IN COMPLIANCE - MAINTAIN GUTTER BUDDY REMOVE SEDIMENT BUILD UP, CLEAN DEBRIS SPILLED OVER CURB LINE, PROTECT STORM INLET, REMOVE PORTA JOHN FROM TOP OF INLET
Gas Service Inspection - Residential Not Ready 12/27/2021 12/27/2021 12/27/2021
Miscellaneous Correction
Corrective Action Required
12/15/2021
PROVIDE MINIMUM 10 PSI FOR 15 MINUTES 12/27/21 0 PSI Michael Harkins 12/27/2021 9:57 AM
All Rough Inspection - Residential Failed 12/29/2021 12/29/2021 12/29/2021
Misc
Corrective Action Required
12/15/2021
-FB soffit line, rim joist, and furout for insulation at mechanical in 2 car bay -Seal fire block top of ductwork.pantry -Provide protection plate at 3” waste pipe at ceiling living room -Complete through bolts on I beam at dining room -Secure bottom of steel post at stairway -Provide LIBs per plan -Complete vent ductwork upstairs -Seal floor penetration second floor fireplace -Provide protection plate at sump discharge line in stair landing -Flash and install missing windows
Gas Service Inspection - Residential Passed 12/29/2021 12/29/2021 12/29/2021
Miscellaneous Correction
Corrective Action Required
12/27/2021
PROVIDE MINIMUM 10 PSI FOR 15 MINUTES 12/27/21 0 PSI Michael Harkins 12/27/2021 9:57 AM
All Rough Inspection - Residential Passed 1/5/2022 1/5/2022 01/05/2022
Misc
Informational
01/05/2022
-Flash and install missing windows
Erosion Control Inspection Residential Failed 2/25/2022 02/25/2022
Miscellaneous Correction
Corrective Action Required
02/25/2022
02/25/22 -CORRECTIONS REQUIRED WITHIN 2 BUSINESS DAYS- -NO FURTHER INSPECTIONS UNTIL IN COMPLIANCE - CLEAN DEBRIS SPILLED OVER CURB LINE, PROTECT STORM INLET ( SILT FENCE )
Plot Plan Inspection Failed 2/25/2022 02/25/2022
Miscellaneous Correction
Corrective Action Required
02/25/2022
LOT SNOW COVERED REMOVE TRASH & CONSTRUCTION DEBRIS PROVIDE SILT FENCE AT CURB INLET
All Rough Inspection - Residential Failed 6/10/2022 06/10/2022
Miscellaneous Correction
Corrective Action Required
06/10/2022
Basement finish - Fire block above electrical panel - Fire block foam gaps in soffit near window - Add more support for soffit over 4’ - Fire block gaps in vertical FB through out - Fire block penetration at top plate garage wall - Provide Boca plates DWV in closet - Fire block penetration top plate bedroom 6 back wall
All Rough Inspection - Residential Passed 6/14/2022 6/14/2022 06/14/2022
Miscellaneous Correction
Resolved
06/14/2022
Basement finish - Fire block above electrical panel - Fire block foam gaps in soffit near window - Add more support for soffit over 4’ - Fire block gaps in vertical FB through out - Fire block penetration at top plate garage wall - Provide Boca plates DWV in closet - Fire block penetration top plate bedroom 6 back wall
Erosion Control Inspection Residential Passed 08/12/2022
Miscellaneous Correction
Resolved
08/12/2022
02/25/22 -CORRECTIONS REQUIRED WITHIN 2 BUSINESS DAYS- -NO FURTHER INSPECTIONS UNTIL IN COMPLIANCE - CLEAN DEBRIS SPILLED OVER CURB LINE, PROTECT STORM INLET ( SILT FENCE )
Plot Plan Inspection Passed 8/12/2022 08/12/2022
Miscellaneous Correction
Resolved
08/12/2022
LOT SNOW COVERED REMOVE TRASH & CONSTRUCTION DEBRIS PROVIDE SILT FENCE AT CURB INLET
Occupancy Inspection - Codes Residential Failed 8/12/2022 8/12/2022 08/12/2022
Misc
Corrective Action Required
08/12/2022
-Seal exterior wall penetrations; seal above meter, AC disconnect, seal exterior lights, etc -Fix and raise the lawn irrigation box. Cannot close the lid -Provide sewer tracer wire port at grade -Middle and master bedroom smoke alarms are not interconnected with the rest of smoke alarms -Provide access to the hydro tub motor and receptacle -Close underneath boxes out wall with 5/8” GB or fire block -Secure water service pex line to wall -Locate and make accessible the sewer clean out
Occupancy Inspection - Codes Residential Full C of O 8/16/2022 8/16/2022 08/16/2022
Misc
Resolved
08/16/2022
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home