Summary
PRRES20212204
Building Permit - Residential
Certificate of Occupancy
SAB CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINSIHED BASEMENT - COVERED DECK
05/04/2021
05/10/2021
10/03/2022
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
SAB CONSTRUCTION LLC, Address:PO BOX 942, Phone:(816) 524-3855  
zbryant@sabhomes.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $510.00 $510.00 Paid 05/10/2021
9110078-Valuation Fee New Single Family $1,090.56 $1,090.56 Paid 05/10/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/10/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/10/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 05/10/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/10/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 8/23/2021 8/23/2021 08/23/2021
Sewer Service Inspection - R Passed 8/24/2021 (8:00) 8/24/2021 08/24/2021
Water Service Inspection - R Passed 8/24/2021 (9:30) 8/24/2021 08/24/2021
Footing Inspection - Residential Passed 08/25/2021
Informational
08/25/2021
FOOTING APPROVED BY ENGINEER
Piers/Caissons Inspection - Residential Passed 10/26/2021 10/26/2021
All Rough Inspection - Residential Failed 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/17/2022
-Nail siding to sill plate per code -Protect wiring running across studdings and joists where located within 6 ft of both attic accesses -Nail stud at master shower wall intersection -Seal gap at top of return air space at master toilet wall -Fb master toilet wall from roof; wall at master bedroom door; -Connect duct to master bathroom fan -Fill in gap at master bedroom exterior door strike plate side with solid wood per security code -Install fireplace -Hanger not fully nailed at lvl connection near kitchen island -Add more nailing to garage PFH wall header-h-frame section -Garage anchors not within middle 1/3 of sill plates -Nail all stud shoe nail holes near service -Fb exterior basement wall space from fur down ceiling and soffit space; Fb gap at vertical fire blockings -Over notched joist below front bathroom tub -Seal all holes and penetrations of ceiling return air space -Toe nail joists to basement foundation wall sill plates and top plates per code -Gas pipe bonding clamp at rebar must be clamp listed for rebar application that also isolate dissimilar metals -Unblock return air at wall outside unfinished basement -The vent connection cannot be below the master shower trap weir -Sister stud to the over-cut studs at bottom ends -Support joists at bedroom 3 return air space -Fb dead space at basement bathroom tub; Fb gap between wall top plate and foundation wall; Fb wall at bedroom 4 -Cannot use laundry drain to vent basement bathroom sink **DO NOT INSULATE
Electrical Service Inspection Failed 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/17/2022
-Ground service to ufer rebar with listed clamp for aluminum conductor. Use the listed aluminum (nickel cladded) clamp and flip the bottom half around for tight connection to rebar
Gas Service Inspection - Residential Failed 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/17/2022
-Provide min ten psi pressure for testing
All Rough Inspection - Residential Failed 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/17/2022
-Nail siding to sill plate per code -Nail stud at master shower wall intersection -Seal gap at top of return air space at master toilet wall -Fb master toilet wall from roof; wall at master bedroom door -Install fireplace **install wiring connector at entry into fireplace -Nail all stud shoe nail holes near service -Fb exterior basement wall space from fur down ceiling and soffit space; Fb gap at vertical fire blockings -Over notched joist below front bathroom tub -The vent connection cannot be below the master shower trap weir **fb wall plate penetrations at master shower; the front bathroom tub trap venting not done -Support joists at bedroom 3 return air space **just add a blocking under the joists and nail to stud -Fb dead space at basement bathroom tub; Fb wall from joist space at bedroom 4 -Cannot use laundry drain to vent basement bathroom sink **protect plumbing; fasten bottom wall plate to floor; Fb wall plate penetration **OK TO INSULATE
Gas Service Inspection - Residential Passed 3/25/2022 3/25/2022 03/25/2022
Misc
Resolved
03/25/2022
-Provide min ten psi pressure for testing
Electrical Service Inspection Failed 3/25/2022 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/25/2022
-Ground service to ufer rebar with listed clamp for aluminum conductor. Use the listed aluminum clamp and flip the bottom half around for tight connection to rebar **The current clamp appears to be a Greaves GR-DB rebar clamp listed for copper conductor only. Provide info for the clamp
Electrical Service Inspection Failed 3/25/2022 03/25/2022
Misc
Corrective Action Required
03/25/2022
-Ground service to ufer rebar with listed clamp for aluminum conductor. Use the listed aluminum clamp and flip the bottom half around for tight connection to rebar **The current clamp appears to be a Greaves GR-DB rebar clamp listed for copper conductor only. Provide info for the clamp
All Rough Inspection - Residential Failed 4/4/2022 4/4/2022 04/04/2022
Misc
Corrective Action Required
03/25/2022
-Fb master toilet wall from roof; wall at master bedroom door -Fb dead space at basement bathroom tub; Fb wall from joist space at bedroom 4 -Cannot use laundry drain to vent basement bathroom sink **protect plumbing **OK TO INSULATE
Electrical Service Inspection Failed 4/4/2022 4/4/2022 04/04/2022
Misc
Corrective Action Required
03/25/2022
-Ground service to ufer rebar with listed clamp for aluminum conductor. Use the listed aluminum clamp and flip the bottom half around for tight connection to rebar **The current clamp appears to be a Greaves GR-DB rebar clamp listed for copper conductor only. Provide info for the clamp
All Rough Inspection - Residential Passed 04/05/2022
Misc
Resolved
04/05/2022
-Fb master toilet wall from roof; wall at master bedroom door -Fb dead space at basement bathroom tub; Fb wall from joist space at bedroom 4 -Cannot use laundry drain to vent basement bathroom sink **protect plumbing **OK TO INSULATE
Electrical Service Inspection Passed 4/5/2022 04/05/2022
Misc
Resolved
04/05/2022
-Ground service to ufer rebar with listed clamp for aluminum conductor. Use the listed aluminum clamp and flip the bottom half around for tight connection to rebar **The current clamp appears to be a Greaves GR-DB rebar clamp listed for copper conductor only. Provide info for the clamp
Driveway Inspection Partial 6/22/2022 6/22/2022 06/22/2022
Misc
Informational
06/22/2022
Driveway was framed up with aggregate in and compacted. 6/22/22 ES
Driveway Inspection Passed 6/27/2022 6/27/2022 06/27/2022
Misc
Informational
06/22/2022
Driveway was framed up with aggregate in and compacted. 6/22/22 ES
Sidewalk Inspection Partial 6/28/2022 6/28/2022 06/28/2022
Misc
Informational
06/28/2022
6-28-22 AN forms are in place and aggregate is present and compacted
Sidewalk Inspection Passed 7/5/2022 7/5/2022 07/06/2022
Misc
Informational
06/28/2022
6-28-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
07/06/2022
7-6-22 AN sidewalk looks good and meets Ada
Occupancy Inspection - Codes Residential Failed 8/9/2022 8/9/2022 08/09/2022
Misc
Corrective Action Required
08/09/2022
- Sod, erosion conttrol, splashblocks, sump pump discharge. - final grade - egress ladder missing -bolt deck to house. - uncover and inspect water meter.
Occupancy Inspection - Codes Residential Full C of O 10/3/2022 10/3/2022 10/03/2022
Misc
Resolved
10/03/2022
- Sod, erosion conttrol, splashblocks, sump pump discharge. - final grade - egress ladder missing -bolt deck to house. - uncover and inspect water meter.
Documents & Images
Date Uploaded File Type Document Name
05/05/2021 Approved Plans APPROVED PLANS
05/05/2021 Approved Plans COMBUSTION AIR CALCS.
05/07/2021 Permit Codes Residential Plan Review
05/10/2021 Receipt Receipt for transaction:2021-002789
07/28/2021 Approved Plans APPLICATION
07/28/2021 Approved Plans APPROVED PLOT PLAN
07/28/2021 Approved Plans EXCISE TAX APP.
08/20/2021 Letter DS Building Permit
08/23/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
08/25/2021 M L Crose 4736 NE Jamestown Dr LSMO Monticello Lot 136 3rd Party Footing Inspection Report 8-5-21
08/25/2021 Letter INSPECTION SUMMARY
10/26/2021 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter Field Certificate of Occupancy
10/03/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home