Summary
PRRES20212200
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 08/19/2021 12:00 AM by username 'Nick Lightner'. STOP WORK ORDER removed on 08/26/2021 12:00 AM by username 'Khanh Nguyen'.
05/04/2021
07/09/2021
06/13/2022
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
ROBERT@SABHOMES.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,088.77 $1,088.77 Paid 07/08/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/08/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/08/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 07/08/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 07/08/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 07/08/2021
9110052-NSF Returned Check Fee $25.00 $25.00 Paid 07/08/2021
9110052-NSF Returned Check Fee $25.00 $25.00 Paid 07/08/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 06/18/2021
Informational
06/18/2021
FOOTING APPROVED BY ENGINEER
Erosion Control Inspection Residential Failed 7/9/2021 7/9/2021 07/09/2021
Miscellaneous Correction
Corrective Action Required
07/09/2021
-Restore silt fence at perimeter and storm inlet -Clean debris from storm inlet
Underslab Plumbing Inspection - Residential Passed 7/9/2021 07/09/2021
Sewer Service Inspection - R Passed 7/12/2021 (10:15) 7/12/2021 07/12/2021
Water Service Inspection - R Passed 7/12/2021 (1:00) 7/12/2021 07/12/2021
Piers/Caissons Inspection - Residential Passed 7/14/2021 (9:45) 7/14/2021 07/14/2021
Erosion Control Inspection Residential Failed - Stop Work 8/19/2021 8/19/2021 08/19/2021
Miscellaneous Correction
Corrective Action Required
07/09/2021
-Restore silt fence at perimeter and storm inlet -Clean debris from storm inlet
Misc
Corrective Action Required
08/19/2021
8/19/21 NL - Restore silt fence at the front of the lot and clean up the silt on the NE corner of the property. Silt fence needs to be installed in the rear of the lot, original silt fence has been taken over by silt runoff. Due to no fence in the rear shutting down future inspections till items have been corrected.
Erosion Control Inspection Residential Failed - Stop Work 8/25/2021 8/25/2021 08/25/2021
Miscellaneous Correction
Corrective Action Required
08/19/2021
-Restore silt fence at perimeter and storm inlet -Clean debris from storm inlet
Misc
Corrective Action Required
08/19/2021
8/19/21 NL - Restore silt fence at the front of the lot and clean up the silt on the NE corner of the property. Silt fence needs to be installed in the rear of the lot, original silt fence has been taken over by silt runoff. Due to no fence in the rear shutting down future inspections till items have been corrected.
Misc
Corrective Action Required
08/25/2021
8/25/21 NL - Restore silt fence at the front of the lot and clean up the silt on the NE corner of the property. Silt fence needs to be installed in the rear of the lot, original silt fence has been taken over by silt runoff. Due to no fence in the rear shutting down future inspections till items have been corrected.
Erosion Control Inspection Residential Passed 9/1/2021 8/26/2021 08/26/2021
Miscellaneous Correction
Resolved
08/26/2021
-Restore silt fence at perimeter and storm inlet -Clean debris from storm inlet
Misc
Resolved
08/26/2021
8/19/21 NL - Restore silt fence at the front of the lot and clean up the silt on the NE corner of the property. Silt fence needs to be installed in the rear of the lot, original silt fence has been taken over by silt runoff. Due to no fence in the rear shutting down future inspections till items have been corrected.
Misc
Resolved
08/26/2021
8/25/21 NL - Restore silt fence at the front of the lot and clean up the silt on the NE corner of the property. Silt fence needs to be installed in the rear of the lot, original silt fence has been taken over by silt runoff. Due to no fence in the rear shutting down future inspections till items have been corrected.
Gas Service Inspection - Residential Passed 1/28/2022 1/28/2022 01/28/2022
Electrical Service Inspection Passed 1/28/2022 1/28/2022 01/28/2022
All Rough Inspection - Residential Failed 1/28/2022 1/28/2022 01/28/2022
Miscellaneous Correction
Corrective Action Required
01/28/2022
- Hangers needed at joist header garage by electrical - Address over notched joist garage next to entry - Garage ridge support to stair wall - Support hip over garage by entry - Anchor bolt middle third of plate portal frame - Nail rafters to joist per code - Nail off corners garage - Fire block top plate garage entry - Strap top plate garage next to front door - Strap top plate at door way next to kitchen - Address notched joist dining room - Notched ridge beam to deck - Strut to purlin 4’ on center through out - Strut over deck over 45 degrees - Address Notched hip ridge at master bedroom - Deck wall to bedroom wall and dining, Strap walls together at top plate - Seal top plate above entry door - Nails missing both double lvl great room at fire place and kitchen - Fire block tub penetration master - Nail off corners bedroom 2 - Fire block plenum space basement bathroom. DWV through joist - All steel columns are 3 1/2” per plan - Fur out plumbing bedroom 4 closet - Fire block top of fur out top plate basement - Fire block basement fur out at 10’ breaks above foundation or seal below - Nail off corner bedroom 3 basement - Missing nail hanger basement next to stairs landing - Pan off return air switch by stairs - cannot inspect covered deck with sheeting on
All Rough Inspection - Residential Failed 2/18/2022 2/18/2022 02/18/2022
Miscellaneous Correction
Corrective Action Required
01/28/2022
- Address Notched hip ridge at master bedroom **OK TO INSULATE**
Driveway Inspection Partial 4/5/2022 4/5/2022 04/05/2022
Misc
Informational
04/05/2022
4-5-22 AN forms are in place and aggregate is present and compacted.
Sidewalk Inspection Passed 4/8/2022 4/8/2022 04/08/2022
Misc
Informational
04/08/2022
4-8-22 AN sidewalk looks good and meets Ada spec
Sidewalk Inspection Partial 04/14/2022
Misc
Informational
04/14/2022
Sidewalk was framed up with aggregate in and compacted. 4/14/22 ES
Sidewalk Inspection Passed 4/22/2022 4/22/2022 04/25/2022
Misc
Informational
04/14/2022
Sidewalk was framed up with aggregate in and compacted. 4/14/22 ES
Misc
Informational
04/25/2022
Sidewalk meets LS and Ada specs. 4/22/22 ES
All Rough Inspection - Residential Passed 5/17/2022 5/17/2022 05/17/2022
Miscellaneous Correction
Resolved
05/17/2022
- Address Notched hip ridge at master bedroom **OK TO INSULATE**
Occupancy Inspection - Codes Residential Failed 6/3/2022 6/3/2022 06/03/2022
Misc
Corrective Action Required
06/03/2022
**CLEAN STREET AND RESTORE EROSION CONTROL ALONG THE REAR AND SOUTH SIDE OF LOT -Driveway not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension -Seal exterior lights outside garage -Provide sewer tracer wire port at grade -Install two 1/2” through bolts or equivalent at each deck beam-post connection -Provide max 30 amp breaker for AC -Fasten the exterior door embedded jamb brace into studs through the 4 pre-drilled holes -Support water service pex line to foundation wall at mid-height
Driveway Inspection Passed 6/3/2022 6/3/2022 06/03/2022
Misc
Informational
04/05/2022
4-5-22 AN forms are in place and aggregate is present and compacted.
Misc
Informational
06/03/2022
6-3-22 AN driveway looks good and has expansion joints at curb and right of way
Plot Plan Inspection Failed 6/7/2022 06/07/2022
Misc
Corrective Action Required
06/07/2022
Grading is generally ok; however, provide min 6” clearance from grade to bottom of siding
Occupancy Inspection - Codes Residential Temporary C of O 6/8/2022 6/8/2022 06/08/2022
Misc
Corrective Action Required
06/03/2022
**PROVIDE EROSION CONTROL ALONG THE BASIN OR SEED THE DISTURBED SOIL AREA -Final grade **Provide min 6” clearance from grade to siding -Install two 1/2” through bolts or equivalent at each deck beam-post connection
Plot Plan Inspection Passed 06/13/2022
Misc
Resolved
06/13/2022
Grading is generally ok; however, provide min 6” clearance from grade to bottom of siding
Occupancy Inspection - Codes Residential Full C of O 6/13/2022 6/13/2022 06/13/2022
Misc
Resolved
06/13/2022
-Final grade **Provide min 6” clearance from grade to siding -Install two 1/2” through bolts or equivalent at each deck beam-post connection
Documents & Images
Date Uploaded File Type Document Name
05/04/2021 Application Form Permit Application
05/04/2021 Application Form License Tax Form
05/05/2021 MO139 - Air Combustion
05/05/2021 Approved Plans Approved Drawings
05/05/2021 Plot Plan Approved Plot Plan
05/05/2021 Permit Codes Residential Plan Review
05/06/2021 Permit DS Building Permit
05/06/2021 Receipt Receipt for transaction:2021-002645
05/13/2021 Receipt Receipt for transaction:2021-002991
06/18/2021 M L Crose 4724 NE Jamestown Dr LSMO Monticello Lot 139 3rd Party Footing Inspection Report 6-18-21
06/18/2021 Letter INSPECTION SUMMARY
07/08/2021 Receipt Receipt for transaction:2021-005480
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Permit DS Building Permit
07/12/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/14/2021 Letter INSPECTION SUMMARY
08/19/2021 Failed Erosion NE Corner.jpg
08/19/2021 Failed Erosion Rear Lot.jpg
08/19/2021 Letter Stop Work Order
08/25/2021 Letter Stop Work Order
08/25/2021 Letter Stop Work Order
08/26/2021 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
02/18/2022 Letter INSPECTION SUMMARY
03/02/2022 DW FRAMING REPORT1
04/05/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
05/17/2022 DW FRAMING REPORT[1]
05/17/2022 Letter INSPECTION SUMMARY
06/03/2022 Letter INSPECTION SUMMARY
06/03/2022 Letter INSPECTION SUMMARY
06/03/2022 Plot Plan Approved As Graded Plot Plan
06/07/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter Codes Temporary Certificate of Occupancy
06/13/2022 Letter Codes Final Certificate of Occupancy
06/13/2022 Letter Field Certificate of Occupancy
06/13/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home