Permit Application Status

PRRES20212194


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212194
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
05/03/2021
06/14/2021
11/01/2021
10/03/2022
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
zbryant@sabhomes.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $480.00 $480.00 Paid 06/14/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/14/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/14/2021
9110078-Valuation Fee New Single Family $1,093.73 $1,093.73 Paid 06/14/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/14/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/14/2021
$0.00 $0.00 $0.00 N/A
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 9/9/2021 09/09/2021
Underslab Plumbing Inspection - Residential Passed 9/10/2021 09/10/2021
Water Service Inspection - R Passed 9/10/2021 09/10/2021
All Rough Inspection - Residential Failed 3/15/2022 3/15/2022 03/15/2022
Misc
Corrective Action Required
03/15/2022
**RESTORE EROSION CONTROL ALONG THE STREET AND CLEAN UP STREET -Anchor garage PFH walls per code -Install joist hangers above dining area -Fb gap at back wall of fireplace space -Protect water lines at master shower -Support 18” lvl with 3 studs at end -Fb basement bedroom 4 closet wall from ceiling space; Fb gaps at top of vertical fire blockings ; Fb dead space at basement bathroom ; Fb bedroom 3 closet from ceiling space -Master bath tub vent connection cannot be below trap weir **OK TO INSULATE
Electrical Service Inspection Passed 3/15/2022 3/15/2022 03/15/2022
Gas Service Inspection - Residential Failed 3/15/2022 3/15/2022 03/15/2022
Misc
Corrective Action Required
03/15/2022
Provide min ten psi pressure
All Rough Inspection - Residential Failed 3/28/2022 3/28/2022 03/28/2022
Misc
Corrective Action Required
03/15/2022
-Protect water lines at master shower -The vertical fire blocking at rear bedroom exceed way more than ten ft -Master bath tub vent connection cannot be below trap weir **lower the trap down to the wet-vented 3” drain level or install individual vent for the tub trap **OK TO INSULATE
Gas Service Inspection - Residential Passed 3/28/2022 3/28/2022 03/28/2022
Misc
Resolved
03/28/2022
Provide min ten psi pressure
Footing Inspection - Residential Passed 4/1/2022 04/01/2022
Informational
04/01/2022
FOOTING APPROVED BY ENGINEER
All Rough Inspection - Residential Passed 4/1/2022 4/1/2022 04/01/2022
Misc
Resolved
04/01/2022
-The vertical fire blocking at rear bedroom exceed way more than ten ft -Master bath tub vent connection cannot be below trap weir **lower the trap down to the wet-vented 3” drain level or install individual vent for the tub trap **OK TO INSULATE
Driveway Inspection Partial 5/19/2022 05/20/2022
Misc
Informational
05/20/2022
5-20-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Partial 5/23/2022 5/23/2022 06/01/2022
Misc
Informational
05/20/2022
5-20-22 AN forms are in place and aggregate is present and compacted 6-1-22 mistake made. There’s no forms or driveway installed
Sidewalk Inspection Partial 6/29/2022 6/29/2022 06/29/2022
Misc
Informational
06/29/2022
6-29-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Partial 6/29/2022 6/29/2022 06/29/2022
Misc
Informational
06/01/2022
5-20-22 AN forms are in place and aggregate is present and compacted 6-1-22 mistake made. There’s no forms or driveway installed
Misc
Informational
06/29/2022
6-29-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 7/5/2022 7/5/2022 07/06/2022
Misc
Informational
06/29/2022
5-20-22 AN forms are in place and aggregate is present and compacted 6-1-22 mistake made. There’s no forms or driveway installed
Misc
Informational
06/29/2022
6-29-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
07/06/2022
7-6-22 AN driveway looks good and meets Ada spec
Sidewalk Inspection Partial 7/5/2022 7/5/2022 07/06/2022
Misc
Informational
06/29/2022
6-29-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
07/06/2022
7-6-22 AN on the right side of the house the sidewalk is done but the left side still needs to be completed
Occupancy Inspection - Codes Residential Failed 8/9/2022 8/9/2022 08/09/2022
Miscellaneous Correction
Corrective Action Required
08/09/2022
- install sidewalk and obtain approval. - sod, erosion control, splash blocks, sump discharge. -Gravel inside of water meter pit. -provide address. - seal garage attic access, provide full cover. -2nd lock on sliding door.
Plot Plan Inspection Passed 8/9/2022 08/09/2022
Sidewalk Inspection Failed 8/18/2022 8/18/2022 08/19/2022
Misc
Informational
07/06/2022
6-29-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
07/06/2022
7-6-22 AN on the right side of the house the sidewalk is done but the left side still needs to be completed
Misc
Informational
08/19/2022
8-18-22 AN forms are in place and aggregate is present and compacted 8-19-22 AN no White cure on sidewalk!
Sidewalk Inspection Passed 8/22/2022 8/22/2022 08/23/2022
Misc
Informational
08/19/2022
6-29-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
08/19/2022
7-6-22 AN on the right side of the house the sidewalk is done but the left side still needs to be completed
Misc
Informational
08/19/2022
8-18-22 AN forms are in place and aggregate is present and compacted 8-23-22 AN. Sidewalk looks good and meets Ada spec
Occupancy Inspection - Codes Residential Full C of O 10/3/2022 10/3/2022 10/03/2022
Miscellaneous Correction
Resolved
10/03/2022
- install sidewalk and obtain approval. - sod, erosion control, splash blocks, sump discharge. -Gravel inside of water meter pit. -provide address. - seal garage attic access, provide full cover. -2nd lock on sliding door.
Documents & Images
Date Uploaded File Type Document Name
05/03/2021 Application Form Permit Application
05/03/2021 Application Form License Tax Form
05/05/2021 MO113 - Air Combustion Calculation
05/05/2021 Approved Plans Approved Drawings
05/05/2021 Permit Codes Residential Plan Review
05/14/2021 Letter Engineer Letter for walkout/walk-up
05/14/2021 Plot Plan Approved Plot Plan
06/07/2021 Permit Codes Residential Plan Review
06/14/2021 Permit DS Building Permit
06/14/2021 Receipt Receipt for transaction:2021-004379
08/12/2021 M L Crose 4721 NE Freehold Dr LSMO Monticello Lot 113 SAB Permit 2021-2194 3rd Party Footing Inspection Report 8-11-21
09/09/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
05/20/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
08/04/2022 Plot Plan Approved As Graded Plot Plan
08/09/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter Codes Final Certificate of Occupancy
10/03/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home