PRRES20212004
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
04/26/2021
06/29/2021
10/23/2021
06/09/2023
Locations
Contacts
SPELLERBERG ENTERPRISES LLC, Address:613 NE VIEWPARK DR, Phone:(816) 550-5535  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
NEW HEIGHTS ELECTRIC LLC, Address:P O BOX 163, Phone:(816) 625-9504  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
SPELLERBERGENTERPRISES@GMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/14/2021 05/12/2021
Kim Brennan
Residential Plan Review Approved 05/14/2021 05/12/2021
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
05/12/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) Please provede square footage for covered patio
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
05/12/2021

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) Does not specify uninterrupted height
Plot Plan Review Approved 04/28/2021 04/30/2021
Kim Brennan
Deck location
Corrective Action Required
04/26/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show the covered patio
Basement opening elevations
Corrective Action Required
04/26/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
As-graded plot plan
Corrective Action Required
04/26/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Planning Review (RES) Approved 04/28/2021 04/26/2021
Kim Brennan
Residential Plan Review Rejected 04/28/2021 04/26/2021
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
04/26/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) Please provede square footage for covered patio
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
04/26/2021

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) Does not specify uninterrupted height
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,213.52 $1,213.52 Paid 06/29/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/29/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/29/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 06/29/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/29/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/29/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/25/2021 (3:30) 8/25/2021 08/25/2021
Underslab Plumbing Inspection - Residential Failed 9/17/2021 9/17/2021 09/17/2021
P3108.1 Horizontal wet vent permitted
Resolved
09/17/2021
Misc
Corrective Action Required
09/17/2021
no erosion control inspection denied. recall when erosion control is in place.
Sewer Service Inspection - R Passed 9/21/2021 (1:45) 9/21/2021 09/21/2021
Water Service Inspection - R Passed 9/22/2021 (1:00) 9/22/2021 09/22/2021
Underslab Plumbing Inspection - Residential Passed 9/27/2021 9/27/2021 09/27/2021
Misc
Corrective Action Required
09/17/2021
no erosion control inspection denied. recall when erosion control is in place.
Piers/Caissons Inspection - Residential Passed 1/14/2022 (8:00) 1/14/2022 01/14/2022
Erosion Control Inspection Residential Failed 1/14/2022 1/14/2022 01/14/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/14/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Gas Service Inspection - Residential Passed 5/31/2022 5/31/2022 05/31/2022
Electrical Service Inspection Passed 5/31/2022 5/31/2022 05/31/2022
All Rough Inspection - Residential Failed 5/31/2022 5/31/2022 05/31/2022
Misc
Corrective Action Required
05/31/2022
-Anchor bolts to be in middle third of plate at PFH -Sister over notched stud at beam -(2) anchor bolts required per plate at single car bay -Support hip rafter at single car bay -Address joists taper cut greater than 25% at two car bay -Use approved clamps at SEC and replace damaged cable -Provide stud shoe at SEC bore greater than 40% -Fireblock furout wall and chases -Provide stud shoes at kitchen window -Protect nm through floor for 6” at kitchen island -Fireblock hvac chase at dining room -Expose covered deck/ porch framing for inspection -Fireblock dwv chase with approved methods -Land electrical at great room, kitchen, powder room -Address beam only bearing 50% on stud pack at kitchen/great room -CSPF to be Min (2) 2x12 header at great room-See detail on structural plans not provided for inspection -Provide complete plan set for inspection -Missing nails in (2) LVL hanger in dining -Address dining room wall not connected to garage or entry walls at top plate -Address broken/missing stud at full height 2x6 wall at stair landing under double header joist -Missing (2) upset 2x12 for roof bearing above stairs- -Support ridge beam here -Address roof load bearing on ceiling joists in back bedroom -Insulate behind shower -Provide joist hangers at joists in hall -Sister over notched stud in back bed closet -Over notched rafter at back bed closet -Provide Bocca plate protection at top plate drier vent duct -Provide joist hanger master bath, header joist in same location is over notched -Provide bonding screw and jumper at metallic box in master bed -Fireblock stair landing joist space from wall space -Provide hanger on joist in landing not bearing on 1.5” -Provide joist hanger at joist cut for b vent -Exterior nailing pattern at CSPF at great room incomplete
All Rough Inspection - Residential Passed 6/16/2022 6/16/2022 06/16/2022
Misc
Resolved
06/16/2022
Erosion Control Inspection Residential Partial 06/16/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/16/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Driveway Inspection Passed 8/24/2022 08/24/2022
Misc
Informational
08/24/2022
On Wednesday, 8-24-2022. I performed and passed a driveway for placement of concrete at this location.
Plot Plan Inspection Passed 10/4/2022 10/04/2022
Erosion Control Inspection Residential Failed 11/14/2022 11/14/2022 11/14/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/14/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 3/9/2023 3/9/2023 03/09/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/14/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. EROSION CONTROL REQUIRED TO BE IN COMPLIANCE UNTIL SOD IS PLACED
Erosion Control Inspection Residential Failed 4/11/2023 04/11/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/09/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. EROSION CONTROL REQUIRED TO BE IN COMPLIANCE UNTIL SOD IS PLACED
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/11/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 6/1/2023 6/1/2023 06/01/2023
Miscellaneous Correction
Corrective Action Required
06/01/2023
- Exterior front door entry lights need to be sealed if under 8 feet tall - Kitchen to patio door knob does not work, also when fixed make sure there are (2) 3 inch security screws per hinge - Garage GFCI will not reset - Garage water irrigation plug needs to state it is non GFCI protected - Interior vertical wood above overhead garage doors need to be sealed at the ceiling - Upstairs north bathroom is missing the pop up drain stopper - Sump pump plug needs to state it is non GFCI protected - Steel column posts in basement need to have nuts tighten at the base - Sump pump discharge needs to point 36 inches from the foundation - A/C whip needs to be secured within 12 inches of the disconnect - There is a lawn irrigation system installed, but no permit has been obtained
Erosion Control Inspection Residential Passed 6/1/2023 06/01/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/11/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. EROSION CONTROL REQUIRED TO BE IN COMPLIANCE UNTIL SOD IS PLACED
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/11/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 6/9/2023 6/9/2023 06/09/2023
Miscellaneous Correction
Resolved
06/09/2023
- Exterior front door entry lights need to be sealed if under 8 feet tall - Kitchen to patio door knob does not work, also when fixed make sure there are (2) 3 inch security screws per hinge - Garage GFCI will not reset - Garage water irrigation plug needs to state it is non GFCI protected - Interior vertical wood above overhead garage doors need to be sealed at the ceiling - Upstairs north bathroom is missing the pop up drain stopper - Sump pump plug needs to state it is non GFCI protected - Steel column posts in basement need to have nuts tighten at the base - Sump pump discharge needs to point 36 inches from the foundation - A/C whip needs to be secured within 12 inches of the disconnect - There is a lawn irrigation system installed, but no permit has been obtained
Documents & Images
Date Uploaded File Type Document Name
04/26/2021 Application Form Permit Application and License Tax Form
04/26/2021 Letter Codes Residential Plan Review
04/30/2021 Plot Plan Approved Plot Plan
05/12/2021 Approved Plans Approved Drawings
06/29/2021 Permit DS Building Permit
06/29/2021 Receipt Receipt for transaction:2021-005128
08/25/2021 Letter INSPECTION SUMMARY
08/26/2021 513 SE CARTER RD - SOIL INSP
09/17/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
06/15/2022 Spellerberg 513 Carter R-I
06/16/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
08/24/2022 Letter INSPECTION SUMMARY
10/03/2022 Plot Plan Approved As Graded Plot Plan
10/04/2022 Letter INSPECTION SUMMARY
11/14/2022 Letter INSPECTION SUMMARY
03/09/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
06/09/2023 Letter Field Certificate of Occupancy
06/09/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home