Permit Application Status

PRRES20211981


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211981
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO
04/22/2021
05/13/2021
10/27/2021
11/09/2022
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
TRUMARKHOMES.MARK@GMAIL.COM  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/04/2021 04/30/2021
Brandon Kalwei
Legal description
Corrective Action Required
04/30/2021

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. missing phase number
Basement elevation
Corrective Action Required
04/30/2021

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.)
Basement opening elevations
Corrective Action Required
04/30/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
As-graded plot plan
Corrective Action Required
04/30/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
City infrustructure
Corrective Action Required
04/30/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. add 8" water line in front of lot on plot plan
Residential Plan Review Approved 05/04/2021 04/30/2021
Brandon Kalwei
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
04/30/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) smoke detector needed for bedroom #5
10 Combustion air
Corrective Action Required
04/30/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
Plot Plan Review Rejected 04/27/2021 04/23/2021
Brandon Kalwei
Legal description
Corrective Action Required
04/23/2021

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. missing phase number
Basement elevation
Corrective Action Required
04/23/2021

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.)
Basement opening elevations
Corrective Action Required
04/23/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
As-graded plot plan
Corrective Action Required
04/23/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
City infrustructure
Corrective Action Required
04/23/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. add 8" water line in front of lot on plot plan
Residential Plan Review Rejected 04/27/2021 04/23/2021
Brandon Kalwei
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
04/23/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) smoke detector needed for bedroom #5
10 Combustion air
Corrective Action Required
04/23/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $997.63 $997.63 Paid 05/12/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 05/12/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/12/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/12/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/12/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/19/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/28/2021 5/28/2021 05/28/2021
Misc
Informational
05/28/2021
3rd party inspection performed by David Ainsworth 5-26-21
Underslab Plumbing Inspection - Residential Passed 6/22/2021 6/22/2021 06/22/2021
Piers/Caissons Inspection - Residential Passed 6/23/2021 (8:00) 6/23/2021 06/23/2021
Sewer Service Inspection - R Failed 8/12/2021 (8:00) 8/12/2021 08/12/2021
Misc
Corrective Action Required
08/12/2021
-Remove scrap pipe from trench and properly bed sewer line in gravel
Sewer Service Inspection - R Not Ready 8/13/2021 08/13/2021
Misc
Corrective Action Required
08/12/2021
8-13-21 ***NOT READY -Remove scrap pipe from trench and properly bed sewer line in gravel per P2604
Water Service Inspection - R Failed 8/13/2021 08/13/2021
Misc
Corrective Action Required
08/13/2021
-10' of copper required from meter to house
Sewer Service Inspection - R Passed 8/19/2021 (8:00) 8/19/2021 08/19/2021
Misc
Resolved
08/19/2021
8-13-21 ***NOT READY -Remove scrap pipe from trench and properly bed sewer line in gravel per P2604
Water Service Inspection - R Passed 8/20/2021 (1:00) 8/20/2021 08/20/2021
Misc
Resolved
08/20/2021
-10' of copper required from meter to house
Erosion Control Inspection Residential Failed 08/23/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/23/2021
*8-23-21 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -RESTORE EROSION CONTROL AT PERIMETER AND CLEAN STREET
Rough Framing Inspection - Residential Failed 9/30/2021 9/30/2021 09/30/2021
Misc
Corrective Action Required
09/30/2021
Portal Frame inspection: -Complete nailing pattern at bottom plate -Horizontal seam to be in middle 2' of portal leg, solid blocked and nailed 3" oc -Interior tension strap to extend from top plate to jack studs -Nail top plate to header connection with 2 rows 16d sinkers 3" oc -PFH requires (2) bottom plate and 5/8" anchor bolt with 2x2x3/16" square washer **Do not cover- will inspect at rough in
Driveway Inspection Passed 10/22/2021 10/22/2021 10/22/2021
Misc
Informational
10/22/2021
On Friday, 10-22-2021. I performed a drive approach inspection and passed the forming and sub-grade for concrete placement.
All Rough Inspection - Residential Failed 11/8/2021 11/8/2021 11/08/2021
Misc
Corrective Action Required
09/30/2021
-fix downed silt fence -Horizontal seam to be in middle 2' of portal leg, solid blocked and nailed 3" oc -Nail top plate to header connection with 2 rows 16d sinkers 3" oc -PFH requires (2) bottom plate and 5/8" anchor bolt with 2x2x3/16" square washer -seal floor penetrations at kitchen island -address over notched lvl above dining area at exterior wall -nail LVL’s 16” OC -fb under entry tub -install windows at front door -seal top plate penetration at SE bed room -provide Purlin’s per plans -provide egress window -solid block cantilever’s -support ward flex in furr down -seal vertical to horizontal penetrations above West wall basement windows -provide beam per plans at stairs -outlet spacing at stair wall basement -instal rated floor box at living room stair wall -install bonding for gas line -solid block or install 3/4 plywood on cripple wall in garage above I-beam
Erosion Control Inspection Residential Failed 11/8/2021 11/8/2021 11/08/2021
DCM3 ESC REQUIRED 2 DAY
Resolved
11/08/2021
11/08/21
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/08/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/08/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/08/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/08/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Electrical Service Inspection Passed 11/8/2021 11/8/2021 11/08/2021
Gas Service Inspection - Residential Failed 11/8/2021 11/8/2021 11/08/2021
Misc
Corrective Action Required
11/08/2021
Gas line needs bonding
Gas Service Inspection - Residential Passed 11/19/2021 11/19/2021 11/19/2021
Misc
Resolved
11/19/2021
Gas line needs bonding
All Rough Inspection - Residential Failed 11/19/2021 11/19/2021 11/19/2021
Misc
Corrective Action Required
11/08/2021
-Horizontal seam to be in middle 2' of portal leg, solid blocked and nailed 3" oc -PFH requires (2) bottom plate and 5/8" anchor bolt with 2x2x3/16" square washer -address over notched lvl above dining area at exterior wall -nail LVL’s 16” OC -provide beam per plans at stairs -instal rated floor box at living room stair wall -solid block or install 3/4 plywood on cripple wall in garage above I-beam
All Rough Inspection - Residential Failed 11/22/2021 11/22/2021 11/22/2021
Misc
Corrective Action Required
11/19/2021
-Horizontal seam solid blocked and nailed 3" oc at PFH -address over notched lvl above dining area at exterior wall -provide beam per plans at stairs -instal rated floor box at living room stair wall
All Rough Inspection - Residential Passed 11/24/2021 11/24/2021
Misc
Corrective Action Required
11/22/2021
-instal rated floor box at living room stair wall
Occupancy Inspection - Codes Residential Failed 6/8/2022 06/08/2022
Misc
Corrective Action Required
06/08/2022
-submit as graded plot plan for review and approval -final grade and sod -splash blocks -GFCI protection at kitchen countertop receptacles -provide hammer arrestors at washing machine -complete hot water heater install -provide water pressure regulator main water line -handrail at basement stairs should terminate above top rise of stairs
Occupancy Inspection - Codes Residential Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/08/2022
-submit as graded plot plan for review and approval -final grade and sod -splash blocks
Plot Plan Inspection Passed 6/22/2022 06/22/2022
Occupancy Inspection - Codes Residential Temporary C of O 6/22/2022 6/22/2022 06/22/2022
Misc
Corrective Action Required
06/21/2022
-final grade and sod **OK FOR TCO, TCO EXPIRES 7/13/22
Erosion Control Inspection Residential Passed 11/09/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
11/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Resolved
11/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Resolved
11/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Resolved
11/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 11/9/2022 11/09/2022
Misc
Resolved
11/09/2022
-final grade and sod **OK FOR TCO, TCO EXPIRES 7/13/22
Documents & Images
Date Uploaded File Type Document Name
04/22/2021 Application Form APPLICATION
04/22/2021 PLOT PLAN LOT 21 COBEY CREEK
04/22/2021 LOT 21 COBEY CREEK SEALED PLANS 2
04/23/2021 Letter Codes Residential Plan Review
04/30/2021 21 COBEY PLOT PLAN
04/30/2021 21 COBEY PLANS #2
04/30/2021 Approved Plans APPROVED PLANS
04/30/2021 Plot Plan APPROVED PLOT PLAN
05/12/2021 Permit DS Building Permit
05/12/2021 Receipt Receipt for transaction:2021-002971
05/27/2021 Garys Fndn 505 SE Carter Rd Lee's Greenwood Mo Cobey Creek Lot 21 3rd Party Footing Inspection Report 5-26-21
05/28/2021 Letter INSPECTION SUMMARY
06/22/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/19/2021 Receipt Receipt for transaction:2021-008840
11/19/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
11/22/2021 Letter INSPECTION SUMMARY
11/23/2021 505 SE Carter Rd LSMO Lot 21 Cobey Creek Construction Issues Inspection Report 11-22-21
11/24/2021 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/21/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
06/21/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter Codes Temporary Certificate of Occupancy
06/27/2022 Scan_0057
11/09/2022 Letter INSPECTION SUMMARY
11/09/2022 Letter Field Certificate of Occupancy
11/09/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home