Permit Application Status

PRRES20211881


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211881
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINSHED BASEMENT - COVERED DECK
04/19/2021
04/21/2021
10/17/2021
09/12/2022
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/23/2021 04/21/2021
Kim Brennan
Signed and sealed
Corrective Action Required
04/21/2021

Plot plan must drawn, signed, and sealed by a licensed surveyor or engineer.
Deck location
Corrective Action Required
04/21/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered patio
Sidewalks
Corrective Action Required
04/21/2021

Sidewalks with dimensions must be provided on the plot plan.
Lot elevations
Corrective Action Required
04/21/2021

Existing and finish elevations at all property corners must be provided on the plot plan. No elevation shown for rear right side corner
Drainage swales/berms
Corrective Action Required
04/21/2021

Drainage swales/berms: provide cross-section elevations as required to conform to the accepted "As graded" Master Drainge Plan (MDP), include cross-section detail from MDP.
As-graded plot plan
Corrective Action Required
04/21/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 04/23/2021 04/21/2021
Kim Brennan
Plot Plan Review Rejected 04/21/2021 04/20/2021
Kim Brennan
Signed and sealed
Corrective Action Required
04/19/2021

Plot plan must drawn, signed, and sealed by a licensed surveyor or engineer.
Deck location
Corrective Action Required
04/19/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered patio
Sidewalks
Corrective Action Required
04/19/2021

Sidewalks with dimensions must be provided on the plot plan.
Lot elevations
Corrective Action Required
04/19/2021

Existing and finish elevations at all property corners must be provided on the plot plan. No elevation shown for rear right side corner
Drainage swales/berms
Corrective Action Required
04/19/2021

Drainage swales/berms: provide cross-section elevations as required to conform to the accepted "As graded" Master Drainge Plan (MDP), include cross-section detail from MDP.
As-graded plot plan
Corrective Action Required
04/19/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 04/21/2021 04/19/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,196.28 $1,196.28 Paid 04/21/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/21/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/21/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 04/21/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/21/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/21/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/17/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 6/9/2021 (10:00) 6/9/2021 06/09/2021
Miscellaneous Correction
Corrective Action Required
06/09/2021
-PIER PADS TO BE 12" DEEP PER PLANS
Erosion Control Inspection Residential Failed 8/4/2021 08/04/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/04/2021
*8-4-21 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. PROVIDE EROSION CONTROL AT PERIMETER OF LOT -PROTECT SWALE AND FIELD INLET
Underslab Plumbing Inspection - Residential Passed 8/4/2021 8/4/2021 08/04/2021
Miscellaneous Correction
Corrective Action Required
08/04/2021
-POST ADDRESS
All Rough Inspection - Residential Failed 9/8/2021 9/8/2021 09/08/2021
Misc
Corrective Action Required
09/08/2021
9-8-21 Portal frame at exterior only ok to cover
Piers/Caissons Inspection - Residential Passed 9/30/2021 (9:45) 9/30/2021 09/30/2021
Erosion Control Inspection Residential Failed 9/30/2021 9/30/2021 09/30/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
09/30/2021
*8-4-21 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. PROVIDE EROSION CONTROL AT PERIMETER OF LOT -PROTECT SWALE AND FIELD INLET
Misc
Corrective Action Required
09/30/2021
9-30-21 -Re establish silt fence, gravel filter and clean trash and debris from site
Gas Service Inspection - Residential Passed 11/23/2021 11/23/2021 11/23/2021
Electrical Service Inspection Failed 11/23/2021 11/23/2021 11/23/2021
Miscellaneous Correction
Corrective Action Required
11/23/2021
No bonding to gas line
All Rough Inspection - Residential Failed 11/23/2021 11/23/2021 11/23/2021
Misc
Corrective Action Required
09/08/2021
9-8-21 Portal frame at exterior only ok to cover
Miscellaneous Correction
Corrective Action Required
11/23/2021
- anchor bolts 12” from plate break single garage and anchor back of garage - Nails missing on hanger above refrigerator - Seal penetration garage steps to basement - Missing joist hanger master bathroom
Miscellaneous Correction
Corrective Action Required
11/23/2021
- anchor bolts 12” from plate break single garage and anchor back of garage - Nails missing on hanger above refrigerator - Seal penetration garage steps to basement - Missing joist hanger master bathroom - fire block return air space penetration in flex room - joist hangers garage - fur out plumbing in garage - secure wiring to fire place - pex must be 6” away from can lights main floor -install snow blocking at flashing and nail siding - move valley support from closet to Bering wall front bedroom - add outlet master bedroom short wall near bathroom - nail protection master shower
Miscellaneous Correction
Corrective Action Required
11/23/2021
- anchor bolts 12” from plate break single garage and anchor back of garage - Nails missing on hanger above refrigerator - Seal penetration garage steps to basement - Missing joist hanger master bathroom - fire block return air space penetration in flex room - joist hangers garage - fur out plumbing in garage - secure wiring to fire place - pex must be 6” away from can lights main floor -install snow blocking at flashing and nail siding - move valley support from closet to Bering wall front bedroom - add outlet master bedroom short wall near bathroom - nail protection master shower
All Rough Inspection - Residential Passed 12/2/2021 12/2/2021 12/02/2021
Misc
Informational
12/02/2021
9-8-21 Portal frame at exterior only ok to cover
Miscellaneous Correction
Resolved
12/02/2021
Miscellaneous Correction
Resolved
12/02/2021
Miscellaneous Correction
Resolved
12/02/2021
Electrical Service Inspection Passed 12/3/2021 12/3/2021 12/03/2021
Miscellaneous Correction
Resolved
12/03/2021
Sewer Service Inspection - R Passed 3/8/2022 (11:15) 3/8/2022 03/08/2022
Water Service Inspection - R Passed 3/9/2022 (8:00) 3/9/2022 03/09/2022
Sidewalk Inspection Partial 3/15/2022 3/15/2022 03/15/2022
Misc
Informational
03/15/2022
On Tuesday 3.15.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete. There was existing handicap ramp and existing curb inlet/storm box. Expansion joints were recommended for storm box because of wall thickness and doweling was recommended for existing h/c ramp pad.
Occupancy Inspection - Codes Residential Failed 3/16/2022 3/16/2022 03/16/2022
Misc
Corrective Action Required
03/16/2022
-Final grade and sod -complete gutters -down spouts and sump pump discharge to extend 36” from foundation -supply attic access panel -complete driveway and sidewalk inspections pending -address footing poured without passed inspection
Occupancy Inspection - Codes Residential Not Ready 3/17/2022 3/17/2022 03/17/2022
Misc
Corrective Action Required
03/16/2022
-Final grade and sod -complete gutters -down spouts and sump pump discharge to extend 36” from foundation -supply attic access panel -complete driveway and sidewalk inspections pending -address footing poured without passed inspection
Occupancy Inspection - Codes Residential Failed 3/18/2022 3/18/2022 03/18/2022
Misc
Corrective Action Required
03/17/2022
-Final grade and sod -complete gutters -down spouts and sump pump discharge to extend 36” from foundation -complete driveway and sidewalk inspections pending -address footing poured without passed inspection
Occupancy Inspection - Codes Residential Temporary C of O 3/18/2022 03/18/2022
Misc
Corrective Action Required
03/18/2022
-Final grade and sod -complete gutters -down spouts and sump pump discharge to extend 36” from foundation -complete driveway and sidewalk inspections pending
Driveway Inspection Passed 3/15/2022 3/15/2022 04/13/2022
Misc
Informational
03/15/2022
On Tuesday 3.15.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Passed 4/13/2022 4/13/2022 04/29/2022
Misc
Informational
03/15/2022
On Tuesday 3.15.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete. There was existing handicap ramp and existing curb inlet/storm box. Expansion joints were recommended for storm box because of wall thickness and doweling was recommended for existing h/c ramp pad.
Plot Plan Inspection Passed 5/9/2022 05/09/2022
Footing Inspection - Residential Passed 9/12/2022 09/12/2022
Miscellaneous Correction
Resolved
09/12/2022
-PIER PADS TO BE 12" DEEP PER PLANS
Misc
Informational
09/12/2022
addressed in third party engineer report.
Erosion Control Inspection Residential Passed 9/12/2022 09/12/2022
Misc
Resolved
09/12/2022
9-30-21 -Re establish silt fence, gravel filter and clean trash and debris from site
Occupancy Inspection - Codes Residential Full C of O 9/12/2022 9/12/2022 09/12/2022
Misc
Resolved
09/12/2022
-Final grade and sod -complete gutters -down spouts and sump pump discharge to extend 36” from foundation -complete driveway and sidewalk inspections pending
Documents & Images
Date Uploaded File Type Document Name
04/19/2021 Application Form Permit Application and License Tax Form
04/19/2021 Approved Plans Approved Drawings
04/20/2021 Letter Codes Residential Plan Review
04/21/2021 Plot Plan Approved Plot Plan
04/21/2021 Receipt Receipt for transaction:2021-002089
04/21/2021 Letter DS Building Permit
06/09/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
03/17/2022 Receipt Receipt for transaction:2022-001473
03/18/2022 2362 SW HICKORY LN - ROCK SUBGRADE
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter Codes Temporary Certificate of Occupancy
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
05/06/2022 Plot Plan Approved As Graded Plot Plan
05/09/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter Codes Final Certificate of Occupancy
09/12/2022 Letter Field Certificate of Occupancy
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home