Permit Application Status

PRRES20211706


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211706
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
04/09/2021
04/12/2021
10/09/2021
07/08/2022
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
JIM@SABHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/14/2021 04/12/2021
Kim Brennan
Residential Plan Review Approved 04/14/2021 04/12/2021
Kim Brennan
Misc
Corrective Action Required
04/12/2021

The address for the property must be on all pages of the drawings
Plot Plan Review Approved 04/13/2021 04/12/2021
Kim Brennan
Deck location
Corrective Action Required
04/12/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered deck
As-graded plot plan
Corrective Action Required
04/12/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Rejected 04/13/2021 04/12/2021
Kim Brennan
Misc
Corrective Action Required
04/09/2021

The address for the property must be on all pages of the drawings
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $934.25 $934.25 Paid 04/12/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/12/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/12/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 04/12/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/12/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/01/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 6/10/2021 (1:00) 6/10/2021 06/10/2021
Misc
Corrective Action Required
06/10/2021
POST ADDRESS
Footing Inspection - Residential Failed 6/10/2021 06/10/2021
Misc
Corrective Action Required
06/10/2021
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR
Water Service Inspection - R Passed 6/11/2021 6/11/2021 06/11/2021
Underslab Plumbing Inspection - Residential Passed 6/14/2021 6/14/2021 06/14/2021
Erosion Control Inspection Residential Failed 6/14/2021 06/14/2021
Misc
Corrective Action Required
06/14/2021
-Erosion control requires continuous maintenance. Repair damaged sections at front and rear property lines within 48 hours -immediate street cleanup required
Miscellaneous Inspection Failed 6/14/2021 06/14/2021
Misc
Corrective Action Required
06/14/2021
post site address
Footing Inspection - Residential Passed 6/14/2021 06/14/2021
Misc
Resolved
06/14/2021
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR
All Rough Inspection - Residential Not Ready 1/4/2022 1/4/2022 01/04/2022
Misc
Corrective Action Required
01/04/2022
inspection denied to lack of erosion control. fix silt fence.
Erosion Control Inspection Residential Failed 1/4/2022 01/04/2022
Misc
Resolved
01/04/2022
-Erosion control requires continuous maintenance. Repair damaged sections at front and rear property lines within 48 hours -immediate street cleanup required
DCM5 ESC INSP DENIED
Corrective Action Required
01/04/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -FIX EROSION CONTROL AROUND LOT -CLEAN UP STORM INLET AT BACK OF LOT
Electrical Service Inspection Passed 1/11/2022 1/11/2022 01/11/2022
Gas Service Inspection - Residential Failed 1/11/2022 1/11/2022 01/11/2022
Misc
Corrective Action Required
01/11/2022
-GAS PRESSURE OK -COMPLETE GAS LINE BONDING
All Rough Inspection - Residential Failed 1/11/2022 1/11/2022 01/11/2022
Misc
Resolved
01/11/2022
inspection denied to lack of erosion control. fix silt fence.
Misc
Corrective Action Required
01/11/2022
*Revise plans to show what is load bearing and what is not* -remove all roof supports from non bearing walls -nail off double joist hanger above master bath toilet -Security blocking for front door -provide hip legs at hip over dining (revise plans to show hip not extending over bearing wall) -pan off return air front entry -strap top plate where over lap less than 20” front entry -provide mechanical strap where top plate does not intersect with other walls back wall -address Lvl above dining/great room plans show extending past coat closet -provide support to prevent lateral roll for lvl above kitchen -address dining to stairwell wall plans show lvl -nail all intersecting wall corners 12” oc -joist hanger above garage entry -anchor bolts to be tight, in the middle 1/3 & within 12” of bottom plate breaks -complete gas line bonding -seal penetrations in vertical to horizontal fire blocking -anchor bolts to be in the middle third of. Bottom plate in basement -Fire block furred down ends throughout basement -fire block above service panel -fire block basement bath/hall open space -fire block above window bedroom 4 -seal penetrations in return air spaces in basement
All Rough Inspection - Residential Failed 1/18/2022 1/18/2022 01/18/2022
Misc
Corrective Action Required
01/11/2022
*Revise plans to show what is load bearing and what is not* -remove all roof supports from non bearing walls -provide hip legs at hip over dining (revise plans to show hip not extending over bearing wall) -provide mechanical strap where top plate does not intersect with other walls back wall -address Lvl above dining/great room plans show extending past coat closet -anchor bolts to be tight, in the middle 1/3 of bottom plate -seal penetrations in vertical to horizontal fire blocking -anchor bolts to be in the middle third of. Bottom plate in basement -Fire block furred down end east wall basement
Gas Service Inspection - Residential Passed 1/18/2022 1/18/2022 01/18/2022
Misc
Resolved
01/18/2022
-GAS PRESSURE OK -COMPLETE GAS LINE BONDING
All Rough Inspection - Residential Failed 1/28/2022 1/28/2022 01/28/2022
Misc
Corrective Action Required
01/18/2022
-address studs Board for dwv in master bathroom load bearing wall -revise plans to show hip extending over bearing wall -provide mechanical strap where top plate does not intersect with other walls back wall see great room wall -seal penetrations in vertical to horizontal fire blocking
All Rough Inspection - Residential Passed 2/17/2022 2/17/2022 02/17/2022
Misc
Resolved
02/17/2022
-address studs Board for dwv in master bathroom load bearing wall -revise plans to show hip extending over bearing wall -provide mechanical strap where top plate does not intersect with other walls back wall see great room wall -seal penetrations in vertical to horizontal fire blocking
Driveway Inspection Partial 4/27/2022 04/27/2022
Misc
Informational
04/27/2022
On 4.27.2022 I performed a driveway inspection and pass the subgrade for concrete pour.
Piers/Caissons Inspection - Residential Passed 6/30/2022 06/30/2022
Misc
Informational
06/30/2022
addressed in third party footing inspection.
Erosion Control Inspection Residential Failed 6/30/2022 06/30/2022
DCM5 ESC INSP DENIED
Corrective Action Required
01/04/2022
Maintain erosion control at front of lot.
Occupancy Inspection - Codes Residential Failed 6/30/2022 6/30/2022 06/30/2022
Miscellaneous Correction
Corrective Action Required
06/30/2022
driveway inspection pending Pay fee’s Final grading and sod Splash blocks Sump discharge minimum of 36” from foundation Missing nails in joist hangers under deck Seal all exterior penetrations Seal top of meter can and A/C disconnect Attach electrical whip at water heater Uncover smoke detectors
Driveway Inspection Passed 07/01/2022
Misc
Informational
04/27/2022
On 4.27.2022 I performed a driveway inspection and pass the subgrade for concrete pour. 7.1.2022 Driveway appears to be compliant
Occupancy Inspection - Codes Residential Temporary C of O 7/5/2022 7/5/2022 07/05/2022
Miscellaneous Correction
Corrective Action Required
06/30/2022
Final grading and sod Splash blocks Sump discharge minimum of 36” from foundation Seal all exterior penetrations Seal top of meter can and A/C disconnect TCO expires 8/4/22
Occupancy Inspection - Codes Residential Full C of O 7/8/2022 07/08/2022
Miscellaneous Correction
Resolved
07/08/2022
Final grading and sod Splash blocks Sump discharge minimum of 36” from foundation Seal all exterior penetrations Seal top of meter can and A/C disconnect TCO expires 8/4/22
Documents & Images
Date Uploaded File Type Document Name
04/09/2021 Application Form Permit Application
04/09/2021 Application Form License Tax Application
04/09/2021 E731 - Air Combustion
04/12/2021 Letter Codes Residential Plan Review
04/12/2021 Approved Plans Approved Drawings
04/12/2021 Receipt Receipt for transaction:2021-001915
04/12/2021 Letter DS Building Permit
05/27/2021 Plot Plan Approved Plot Plan
05/31/2021 M L Crose 2349 SW Old Port Rd LSMO Eagle Creek Lot 731 SAB Homes P 2021-1706 3rd Party Footing Inspection Report 5-28-21
06/10/2021 Letter INSPECTION SUMMARY
06/11/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/18/2022 DW FRAMING ADDENDUM Hampshire E731 2349 SW Old Port Rd
01/18/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
02/17/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
06/20/2022 Plot Plan Approved As Graded Plot Plan
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Receipt Receipt for transaction:2022-005458
07/05/2022 Letter Codes Temporary Certificate of Occupancy
07/08/2022 Letter Codes Final Certificate of Occupancy
07/21/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home