Permit Application Status

PRRES20211211


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211211
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX IN JKV - NO BASEMENT - COVERED DECK DEFFERED FLOOR JOISTS
03/17/2021
07/14/2021
10/20/2021
08/26/2022
Locations
Contacts
JOHN KNOX VILLAGE, Address:400 NW MURRAY RD  
LARRY HARKRADER CONSTRUCTION, Address:401 NW MURRAY RD, Phone:(816) 607-7191  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
S & L ELECTRIC INC, Address:1301 S POWELL, Phone:(816) 796-6859  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
CHET@HARKRADERCONSTRUCTION.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/14/2021 05/12/2021
Kim Brennan
Front building line
Corrective Action Required
05/12/2021

Front building line and dimension to front of building must be provided on the plot plan.
Deck location
Corrective Action Required
05/12/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Right-of-way
Corrective Action Required
05/12/2021

The right-of-way with dimensions must be provided on the plot plan.
Building elevations
Corrective Action Required
05/12/2021

Existing and finished elevations at building footprint corners must be provided on the plot plan.
Lot elevations
Corrective Action Required
05/12/2021

Existing and finish elevations at all property corners must be provided on the plot plan.
Curb elevation
Corrective Action Required
05/12/2021

The elevation at top of curb at end of driveway and at lot corners adjacent to street must be provided on the plot plan.
Spot elevations
Corrective Action Required
05/12/2021

Spot elevations and drainage flow arrows shall be provided throughout the lot.
City infrustructure
Corrective Action Required
05/12/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures.
Residential Plan Review Approved 05/14/2021 05/12/2021
Kim Brennan
02 One (1) complete license tax application
Corrective Action Required
05/12/2021

One (1) complete license tax application
Misc
Corrective Action Required
05/12/2021

All subs and on-site contact information needs to be completed
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
05/12/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) These need to reflect both sides of the structure.
Miscellaneous Correction
Corrective Action Required
05/12/2021

Drawings need to show both sides of the duplex, not just one side. The drawings only show both sides on the elevations.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
05/12/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
10 Combustion air
Corrective Action Required
05/12/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
12 Detail required separation between garage and living area including door
Corrective Action Required
05/12/2021

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Does not specify self-closing
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
05/12/2021

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
Plot Plan Review Rejected 04/27/2021 04/23/2021
Kim Brennan
Front building line
Corrective Action Required
04/23/2021

Front building line and dimension to front of building must be provided on the plot plan.
Deck location
Corrective Action Required
04/23/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Right-of-way
Corrective Action Required
04/23/2021

The right-of-way with dimensions must be provided on the plot plan.
Building elevations
Corrective Action Required
04/23/2021

Existing and finished elevations at building footprint corners must be provided on the plot plan.
Lot elevations
Corrective Action Required
04/23/2021

Existing and finish elevations at all property corners must be provided on the plot plan.
Curb elevation
Corrective Action Required
04/23/2021

The elevation at top of curb at end of driveway and at lot corners adjacent to street must be provided on the plot plan.
Spot elevations
Corrective Action Required
04/23/2021

Spot elevations and drainage flow arrows shall be provided throughout the lot.
City infrustructure
Corrective Action Required
04/23/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures.
Residential Plan Review Rejected 04/27/2021 04/23/2021
Kim Brennan
02 One (1) complete license tax application
Corrective Action Required
04/23/2021

One (1) complete license tax application
Misc
Corrective Action Required
04/23/2021

All subs and on-site contact information needs to be completed
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
04/23/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) These need to reflect both sides of the structure.
Miscellaneous Correction
Corrective Action Required
04/23/2021

Drawings need to show both sides of the duplex, not just one side. The drawings only show both sides on the elevations.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
04/23/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
10 Combustion air
Corrective Action Required
04/23/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
12 Detail required separation between garage and living area including door
Corrective Action Required
04/23/2021

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Does not specify self-closing
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
04/23/2021

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
Plot Plan Review Rejected 03/23/2021 03/19/2021
Kim Brennan
Front building line
Corrective Action Required
03/19/2021

Front building line and dimension to front of building must be provided on the plot plan.
Deck location
Corrective Action Required
03/19/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Right-of-way
Corrective Action Required
03/19/2021

The right-of-way with dimensions must be provided on the plot plan.
Building elevations
Corrective Action Required
03/19/2021

Existing and finished elevations at building footprint corners must be provided on the plot plan.
Lot elevations
Corrective Action Required
03/19/2021

Existing and finish elevations at all property corners must be provided on the plot plan.
Curb elevation
Corrective Action Required
03/19/2021

The elevation at top of curb at end of driveway and at lot corners adjacent to street must be provided on the plot plan.
Spot elevations
Corrective Action Required
03/19/2021

Spot elevations and drainage flow arrows shall be provided throughout the lot.
City infrustructure
Corrective Action Required
03/19/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures.
Residential Plan Review Rejected 03/23/2021 03/19/2021
Kim Brennan
02 One (1) complete license tax application
Corrective Action Required
03/19/2021

One (1) complete license tax application
Misc
Corrective Action Required
03/19/2021

All subs and on-site contact information needs to be completed
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
03/19/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) These need to reflect both sides of the structure.
Miscellaneous Correction
Corrective Action Required
03/19/2021

Drawings need to show both sides of the duplex, not just one side. The drawings only show both sides on the elevations.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
03/19/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
10 Combustion air
Corrective Action Required
03/19/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
12 Detail required separation between garage and living area including door
Corrective Action Required
03/19/2021

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Does not specify self-closing
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
03/19/2021

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $1,191.90 $1,191.90 Paid 07/14/2021
8331507-Sewer Connection Fee $540.00 $540.00 Paid 07/14/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 08/25/2022
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/27/2021 07/27/2021
Misc
Corrective Action Required
07/27/2021
UFER LOCATED REAR WALL OF GARAGES
Underslab Plumbing Inspection - Residential Passed 8/20/2021 8/20/2021 08/20/2021
Sewer Service Inspection - R Partial 12/20/2021 (3:00) 12/20/2021 12/20/2021
Misc
Informational
12/20/2021
PARTIAL -PRIVATE STREET WYE AT MAIN IN MIDDLE OF STREET PAST CURB -
Underslab Plumbing Inspection - Residential Passed 12/21/2021 12/21/2021 12/21/2021
Misc
Informational
12/21/2021
GARAGE FLOOR DRAINS 626 & 628 OK TO COVER
Sewer Service Inspection - R Partial 12/21/2021 12/21/2021
Misc
Informational
12/20/2021
PARTIAL -PRIVATE STREET WYE AT MAIN IN MIDDLE OF STREET PAST CURB - - FOUNDATION TO 10' PAST FRONT STOOP -
Sewer Service Inspection - R Passed 12/22/2021 (2:00) 12/22/2021 12/22/2021
Misc
Informational
12/21/2021
-PRIVATE STREET WYE AT MAIN IN MIDDLE OF STREET PAST CURB -
Water Service Inspection - R Partial 12/22/2021 (2:00) 12/22/2021 12/22/2021
Misc
Informational
12/22/2021
626 & 628 share a meter PARTIAL TO WEST SIDE OF FRONT PORCH 626 WAITING ON TAP & PIT
Water Service Inspection - R Passed 12/29/2021 12/29/2021
Misc
Informational
12/22/2021
626 & 628 share a meter
Gas Service Inspection - Residential Failed 2/11/2022 2/11/2022 02/11/2022
Miscellaneous Correction
Corrective Action Required
02/11/2022
PROVIDE BOND GAS LINES ( CSST) PROVIDE MIN 10 PSI FOR 15 MINUTES 628 WILLOW
Electrical Service Inspection Failed 2/11/2022 02/11/2022
Miscellaneous Correction
Corrective Action Required
02/11/2022
INSTALL METER CAN WITH DISCONNECTS LAND SEC IN METER CANS & SERVICE PANELS PROVIDE UFER GROUND
All Rough Inspection - Residential Failed 2/11/2022 2/11/2022 02/11/2022
Miscellaneous Correction
Corrective Action Required
02/11/2022
626 & 628 Seal all upward penetrations garage mechanical room Provide 2 layers 5/8 type x garage wall we between units including attic to roof deck @ 2 hour Rated wall assembly inspection required each layer Expose ceiling 3 season room & front porch to inspect rafters & ceiling joist Seal upward penetrations 3 season room Secure & seal gas line at fireplace Provide bath exhaust fans Provide Dbl 2 x 10 ridge above garage per roof framing plan Provide 100 watt flood light rear yard 628 Provide minimum 10 psi on gas line Provide solid blocking at exterior wall sheathing breaks in kitchen & nail per code
Gas Service Inspection - Residential Failed 2/22/2022 2/22/2022 02/22/2022
Miscellaneous Correction
Corrective Action Required
02/11/2022
PROVIDE BOND GAS LINES ( CSST) PRESSURE STEADY BOTH UNITS
All Rough Inspection - Residential Passed 2/22/2022 2/22/2022 02/22/2022
Miscellaneous Correction
Resolved
02/22/2022
Rated Assembly Inspection Partial 3/8/2022 3/8/2022 03/08/2022
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
03/08/2022
1ST LAYER TYPE X PARTY WALL, ATTIC, RAFTERS UNITS 626 & 628
Gas Service Inspection - Residential Failed 3/10/2022 3/10/2022 03/10/2022
Miscellaneous Correction
Corrective Action Required
02/22/2022
PROVIDE BOND GAS LINES ( CSST) PRESSURE STEADY BOTH UNITS
Miscellaneous Correction
Corrective Action Required
03/10/2022
LAND BONDING IN BACKORDERED DISCONNECT
Rated Assembly Inspection Failed 3/10/2022 3/10/2022 03/10/2022
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
03/08/2022
1ST LAYER TYPE X PARTY WALL, ATTIC, RAFTERS UNITS 626 & 628 2ND LAYER TYPE X UNITS 626 & 628
Miscellaneous Correction
Corrective Action Required
03/10/2022
FIRE CAULK ALL PENETRATIONS IN RATED WALL
Electrical Service Inspection Passed 3/18/2022 3/18/2022 03/18/2022
Miscellaneous Correction
Resolved
03/18/2022
Gas Service Inspection - Residential Passed 3/18/2022 3/18/2022 03/18/2022
Miscellaneous Correction
Resolved
03/18/2022
Miscellaneous Correction
Resolved
03/18/2022
Erosion Control Inspection Residential Failed 4/22/2022 04/22/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/22/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE UNTIL SOD COMPLETE CLEAN STREET OF MED & GRAVEL
Plot Plan Inspection Passed 4/22/2022 04/22/2022
Rated Assembly Inspection Failed 4/22/2022 04/22/2022
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
03/10/2022
1ST LAYER TYPE X PARTY WALL, ATTIC, RAFTERS UNITS 626 & 628 2ND LAYER TYPE X UNITS 626 & 628
Miscellaneous Correction
Corrective Action Required
03/10/2022
FIRE CAULK ALL PENETRATIONS IN RATED WALL Seal penetrations at ridge of Rated assembly ( provide ladder for access )
Occupancy Inspection - Codes Residential Failed 4/22/2022 4/22/2022 04/22/2022
Miscellaneous Correction
Corrective Action Required
04/22/2022
626 & 628 Seal penetrations at ridge of Rated assembly ( provide ladder for access ) Provide Hi / lo vent mechanical rooms to exterior per combustion air letter dated 5/11/21 from AFC heating & cooling Provide sod & splash blocks Sump shall discharge 36" from foundation 626 Provide GFCI protection garage receptacles Provide anti tip device range Provide GFCI protection washing machine 628 Provide GFCI protection washing machine Provide GFCI protection master vanity ( open ground ) Provide anti tip device range Provide GFCI protection garage receptacles
Erosion Control Inspection Residential Failed 4/26/2022 04/26/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/22/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE UNTIL SOD COMPLETE CLEAN STREET OF MED & GRAVEL
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
04/26/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Rated Assembly Inspection Passed 4/26/2022 04/26/2022
THE FOLLOWING AREAS ARE APPROVED
Resolved
04/26/2022
1ST LAYER TYPE X PARTY WALL, ATTIC, RAFTERS UNITS 626 & 628 2ND LAYER TYPE X UNITS 626 & 628
Miscellaneous Correction
Resolved
04/26/2022
FIRE CAULK ALL PENETRATIONS IN RATED WALL Seal penetrations at ridge of Rated assembly ( provide ladder for access )
Occupancy Inspection - Codes Residential Temporary C of O 4/26/2022 4/26/2022 04/26/2022
Miscellaneous Correction
Corrective Action Required
04/22/2022
626 & 628 Provide sod & splash blocks Obtain lawn irrigation permit & submit back flow certification
Erosion Control Inspection Residential Passed 8/26/2022 8/26/2022 08/26/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/26/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE UNTIL SOD COMPLETE CLEAN STREET OF MED & GRAVEL
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
08/26/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Occupancy Inspection - Codes Residential Full C of O 8/26/2022 8/26/2022 08/26/2022
Miscellaneous Correction
Resolved
08/26/2022
Documents & Images
Date Uploaded File Type Document Name
03/17/2021 Application Form Permit Application
03/19/2021 Plans JKV2_ARCH_PERMIT_SS (2)
03/19/2021 Letter Codes Residential Plan Review
04/22/2021 License Tax Application
05/04/2021 Plot Plan Approved Plot Plan JKV
05/04/2021 Approved Plans Approved Drawings
05/12/2021 Letter Cumbustion Air Calcs
07/14/2021 Permit DS Building Permit
07/14/2021 Receipt Receipt for transaction:2021-005655
07/27/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
12/29/2021 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/17/2022 John Knox- 626-628 Willow Alternate Garage Framing Review- 02-17-22
02/22/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/25/2022 AFC Combustion air
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter Codes Temporary Certificate of Occupancy
08/25/2022 Receipt Receipt for transaction:2022-006995
08/26/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter Field Certificate of Occupancy
08/26/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home