Permit Application Status

PRRES20211044


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211044
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED PATIO
03/10/2021
03/18/2021
09/08/2021
12/08/2022
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
CRAIGB@NEWMARKHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/22/2021 03/18/2021
Kim Brennan
Contours, spot elevations and arrows
Corrective Action Required
03/18/2021

Contours, spot elevations and drainage flow arrows (as required) shall be provided on the lot. Please add contours to the plot plan
Sidewalks
Corrective Action Required
03/18/2021

Sidewalks with dimensions and ADA ramps must be provided on the plot plan. Please show location of ADA ramp
Residential Plan Review Approved 03/22/2021 03/18/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
03/18/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) No carbon monoxide detectors shown and no smoke detectors in bedroom #4 or outside bedroom #4
Misc
Corrective Action Required
03/18/2021

Please label all pier pads according to the schedule
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
03/18/2021

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) Does not sepcify uninterrupted
Plot Plan Review Rejected 03/15/2021 03/12/2021
Kim Brennan
Contours, spot elevations and arrows
Corrective Action Required
03/12/2021

Contours, spot elevations and drainage flow arrows (as required) shall be provided on the lot. Please add contours to the plot plan
Sidewalks
Corrective Action Required
03/12/2021

Sidewalks with dimensions and ADA ramps must be provided on the plot plan. Please show location of ADA ramp
Residential Plan Review Rejected 03/15/2021 03/11/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
03/11/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) No carbon monoxide detectors shown and no smoke detectors in bedroom #4 or outside bedroom #4
Misc
Corrective Action Required
03/11/2021

Please label all pier pads according to the schedule
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
03/11/2021

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) Does not sepcify uninterrupted
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,157.17 $1,157.17 Paid 03/18/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/18/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/18/2021
8331507-Sewer Connection Fee $480.00 $480.00 Paid 03/18/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/18/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/18/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/06/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 4/23/2021 04/23/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/23/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Footing Inspection - Residential Passed 4/23/2021 (9:30) 4/23/2021 04/23/2021
Misc
Informational
04/23/2021
UFER LOCATED SOUTH FOUNDATION WALL
Erosion Control Inspection Residential Failed 5/20/2021 05/20/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/23/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/20/2021
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
Underslab Plumbing Inspection - Residential Passed 6/15/2021 6/15/2021 06/15/2021
Sewer Service Inspection - R Passed 7/8/2021 (1:00) 7/8/2021 07/08/2021
Water Service Inspection - R Passed 7/26/2021 07/26/2021
All Rough Inspection - Residential Failed 9/13/2021 9/13/2021 09/13/2021
Miscellaneous Correction
Corrective Action Required
09/13/2021
: PFH GARAGE PORTAL FRAMING ONLY : TIGHTEN 5/8 ANCHOR BOLTS PROVIDE SOLID BLOCKING AT SHEATHING BREAKS ABOVE DOOR AND NAIL PER CODE FASTEN TOP PLATE TO HEADER WITH TWO ROWS 16D SINKER AT 3' O.C. PER PLAN DETAIL 1 SHEET S4.0
Piers/Caissons Inspection - Residential Passed 11/15/2021 (1:15) 11/15/2021 11/15/2021
Electrical Service Inspection Passed 12/10/2021 12/10/2021 12/10/2021
Gas Service Inspection - Residential Failed 12/10/2021 12/10/2021 12/10/2021
Misc
Corrective Action Required
12/10/2021
GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 12/10/2021 12/10/2021 12/10/2021
Miscellaneous Correction
Corrective Action Required
09/13/2021
: PFH GARAGE PORTAL FRAMING ONLY : PROVIDE SOLID BLOCKING AT SHEATHING BREAKS ABOVE DOOR AND NAIL PER CODE -bocca protection plate must protect at plate and either 2” above bottom plate or below top plate - see garage wall -anchor bolts required within 12” of plate break at garage -nail intersecting wall corners 12" oc -terminate all bath exhaust fans to exterior -protection plate at bottom plate pex and NM, kitchen fridge -rafters not tied to ceiling joists and top plate per code, rafter landing on multiple blocks throughout -seal low volt bottom plate penetration front bedroom -Frame and install jacuzzi tub master bath, rough opening access for circulation pump and receptacle, land NM to box for tub -(3) 2x12 joists at ceiling box in dining room per plans -LIB bracing all locations per plans -CS-PF bracing design at master bedroom per plans, see detail S4.1 in plans -Ensure proper slope all DWV vents span across ceiling joists -fireblock at fireplace open to attic space above through cabinet framing, fireblock between studs at cabinet on hall side -collar ties every 48” oc -all ridge and purlin supports per plans -set and anchor all steel columns to floor at basement -connect 2x4 laid flat at furred down in basement to floor joist above to support ceiling load -support DWV every 48” oc at East basement storage, traps not considered support -secure main water line to foundation wall -Nail all exterior sheathing per plans -Unable to inspect covered patio framing with lid cover
All Rough Inspection - Residential Not Ready 1/4/2022 1/4/2022 01/04/2022
Miscellaneous Correction
Corrective Action Required
12/10/2021
: PFH GARAGE PORTAL FRAMING ONLY : PROVIDE SOLID BLOCKING AT SHEATHING BREAKS ABOVE DOOR AND NAIL PER CODE -nail intersecting wall corners 12" oc -rafters not tied to ceiling joists and top plate per code, rafter landing on multiple blocks throughout ( 2018 IRC R802.5.2) -Frame and install jacuzzi tub master bath, rough opening access for circulation pump and receptacle, land NM to box for tub -fireblock at fireplace fireblock between studs at cabinet on hall side -support DWV every 48” oc at East basement storage, traps not considered support -Nail all exterior sheathing per plans -Unable to inspect covered patio framing with lid cover
Gas Service Inspection - Residential Passed 1/11/2022 1/11/2022 01/11/2022
Misc
Resolved
01/11/2022
All Rough Inspection - Residential Failed 1/14/2022 1/14/2022 01/14/2022
Miscellaneous Correction
Corrective Action Required
01/04/2022
: PFH GARAGE PORTAL FRAMING ONLY : PROVIDE SOLID BLOCKING AT SHEATHING BREAKS ABOVE DOOR AND NAIL PER CODE -nail intersecting wall corners 12" oc -rafters not tied to ceiling joists and top plate per code, rafter landing on multiple blocks throughout ( 2018 IRC R802.5.2) -Frame and install jacuzzi tub master bath, rough opening access for circulation pump and receptacle, land NM to box for tub -fireblock at fireplace fireblock between studs at cabinet on hall side -Nail all exterior sheathing per plans -Unable to inspect covered patio framing with lid
All Rough Inspection - Residential Failed 1/19/2022 01/19/2022
Miscellaneous Correction
Corrective Action Required
01/14/2022
-rafters not tied to ceiling joists and top plate per code, rafter landing on multiple blocks throughout ( 2018 IRC R802.5.2) -Nail all exterior sheathing per plans -Unable to inspect covered patio framing with lid, provide ladder or remove soffit for inspection of roof framing.
All Rough Inspection - Residential Passed 1/31/2022 1/31/2022 01/31/2022
Miscellaneous Correction
Corrective Action Required
01/19/2022
Driveway Inspection Partial 3/4/2022 3/4/2022 03/04/2022
Misc
Informational
03/04/2022
Forms were placed and aggregate was present and compacted. RP 3-4-22
Sidewalk Inspection Partial 3/4/2022 3/4/2022 03/04/2022
Misc
Informational
03/04/2022
Forms were placed and aggregate was present and compacted. Water meter appears high to the sidewalk. RP 3-4-22
Driveway Inspection Passed 3/11/2022 3/11/2022 03/22/2022
Misc
Informational
03/04/2022
Forms were placed and aggregate was present and compacted. RP 3-4-22
Misc
Informational
03/22/2022
Finished driveway meets LS and ADA specs. RP 3-22-22
Sidewalk Inspection Passed 3/11/2022 3/11/2022 03/22/2022
Misc
Informational
03/04/2022
Forms were placed and aggregate was present and compacted. Water meter appears high to the sidewalk. RP 3-4-22
Misc
Informational
03/22/2022
Finished sidewalk meets LS and ADA specs. RP 3-22-22
Erosion Control Inspection Residential Failed 3/23/2022 03/23/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/20/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/20/2021
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/23/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Plot Plan Inspection Passed 12/7/2022 05/27/2022
Occupancy Inspection - Codes Residential Failed 5/27/2022 5/27/2022 05/27/2022
Misc
Corrective Action Required
05/27/2022
- Provide gutters and down spouts - Provide splash blocks - Provide sod - Sump discharge minimum 36” away from foundation - Seal top of meter can and AC disconnect - Provide spark rings at kitchen counter outlets - Seal penetration around drain garage - Label non GFCI outlet in garage - Spark rings required at bar counter outlets - Label non GFCI outlet at sump pump
Erosion Control Inspection Residential Passed 5/27/2022 05/27/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/27/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/27/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - - CLEAN STREET -
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/27/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Temporary C of O 5/31/2022 5/31/2022 05/31/2022
Misc
Corrective Action Required
05/27/2022
- Provide gutters and down spouts - Provide splash blocks - Provide sod - Sump discharge minimum 36” away from foundation - Seal top of meter can and AC disconnect - OBTAIN LAWN IRRIGATION PERMIT & SUBMIT BACK-FLOW CERTIFICATION - : TCO EXPIRES 6/30/2022 :
Occupancy Inspection - Codes Residential Full C of O 12/8/2022 12/8/2022 12/08/2022
Misc
Resolved
12/08/2022
Documents & Images
Date Uploaded File Type Document Name
03/10/2021 Application Form Permit Application and License Tax Form
03/12/2021 Letter Codes Residential Plan Review
03/12/2021 Plot Plan APPROVED PLOT PLAN
03/18/2021 Approved Plans Approved Drawings
03/18/2021 Receipt Receipt for transaction:2021-001355
03/18/2021 Letter DS Building Permit
04/23/2021 Letter INSPECTION SUMMARY
04/23/2021 Letter INSPECTION SUMMARY
04/23/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
09/13/2021 Letter INSPECTION SUMMARY
11/15/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/06/2022 Receipt Receipt for transaction:2022-000108
01/11/2022 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter Codes Temporary Certificate of Occupancy
10/18/2022 Letter Codes 140 Day Letter
12/06/2022 Plot Plan Approved As-Graded Plot Plan
12/08/2022 Letter Field Certificate of Occupancy
12/08/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home