Permit Application Status

PRRES20210903


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210903
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINSIHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 05/03/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 05/03/2021 12:00 AM by username 'Patrick Schonfeldt'.
03/02/2021
03/04/2021
12/08/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/05/2021 03/04/2021
Brandon Kalwei
Residential Plan Review Approved 03/05/2021 03/03/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $860.60 $860.60 Paid 03/04/2021
8331507-Sewer Connection Fee $330.00 $330.00 Paid 03/04/2021
Right of Way Permit Fee $80.00 $80.00 Paid 03/04/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/04/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 03/04/2021
Water Meter Fee $455.54 $455.54 Paid 03/04/2021
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 5/3/2021 5/3/2021 05/03/2021
Misc
Corrective Action Required
05/03/2021
INSPECTION DENIED -FOOTING POURED WITHOUT INPSECTION, ENGINEER REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 2 DAYS OF INSPECTION -CLEAN GRAVEL FROM STREET
Footing Inspection - Residential Failed - Stop Work 5/3/2021 5/3/2021 05/03/2021
Misc
Corrective Action Required
05/03/2021
INSPECTION DENIED -FOOTING POURED WITHOUT INPSECTION, ENGINEER REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 2 DAYS OF INSPECTION -CLEAN GRAVEL FROM STREET
Footing Inspection - Residential Passed 5/3/2021 5/3/2021 05/03/2021
Misc
Resolved
05/03/2021
Underslab Plumbing Inspection - Residential Passed 5/3/2021 5/3/2021 05/03/2021
Misc
Resolved
05/03/2021
Electrical Service Inspection Passed 7/22/2021 7/22/2021 07/22/2021
Gas Service Inspection - Residential Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/22/2021
-GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/22/2021
-strap top plates master closet/garage intersecting corner -Fireblock deadspace basement stairs to attic space -Dbl top plate requires 24” offset between plate breaks, strap plates- see above fireplace -12” oc nailing at all abutting and intersecting wall corners -seal gaps at edges of fireblock lid at fireplace -Truss hangers at covered patio per plans -Fireblock attic space at top plate above fridge bump out in kitchen -Fireblock tub traps -Min (4) 2x4 stud packs at all girder truss bearing ends per plans
Gas Service Inspection - Residential Passed 7/29/2021 7/29/2021 07/29/2021
Misc
Resolved
07/29/2021
All Rough Inspection - Residential Failed 7/29/2021 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/22/2021
-strap top plates master closet/garage wall intersecting corner, no overlap of top plates on braced wall corner -Fireblock deadspace basement stairs to attic space
All Rough Inspection - Residential Failed 7/30/2021 7/30/2021 07/30/2021
Misc
Corrective Action Required
07/29/2021
-Fireblock deadspace basement stairs to attic space, fireblock at lid of attic line
All Rough Inspection - Residential Passed 8/2/2021 8/2/2021 08/02/2021
Misc
Resolved
08/02/2021
Sewer Service Inspection - R Passed 8/30/2021 (11:00) 8/30/2021 08/30/2021
Erosion Control Inspection Residential Failed 8/31/2021 8/31/2021 08/31/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/31/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Water Service Inspection - R Passed 8/31/2021 8/31/2021 08/31/2021
Driveway Inspection Passed 9/16/2021 9/16/2021 09/17/2021
Misc
Informational
09/17/2021
On Thursday. 9-16-2021. I conducted a drive approach inspection and passed the driveway for concrete installation. On Friday, 9-17-2021. I preformed sidewalk inspection and passed walk for concrete installation.
Erosion Control Inspection Residential Failed 11/5/2021 11/05/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/05/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
11/05/2021
Occupancy Inspection - Codes Residential Failed 11/5/2021 11/5/2021 11/05/2021
Misc
Corrective Action Required
11/05/2021
EROSION CONTROL REQUIRED BEFORE NEXT INSPECTION -final sidewalk inspection required -final grade and sod -check water meter at final grade and sod -splash blocks and sump pump discharge 36” from foundation -address open junction box in kitchen -outlet required at stair wall space/living room -anti syphon device on hose bib in basement
Sidewalk Inspection Passed 9/17/2021 9/17/2021 12/03/2021
Misc
Informational
12/03/2021
A sidewalk inspection was preformed sometime in September and did not get properly signed off. Sidewalk passed inspection. Friday, 12-03-2021
Plot Plan Inspection Passed 12/8/2021 12/08/2021
Erosion Control Inspection Residential Passed 12/8/2021 12/08/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
12/08/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Full C of O 12/8/2021 12/8/2021 12/08/2021
Misc
Resolved
12/08/2021
-final sidewalk inspection required
Sidewalk Inspection Not Ready 12/16/2022
Documents & Images
Date Uploaded File Type Document Name
03/02/2021 Application Form APPLICATION
03/02/2021 91 HAWTHORNE RIDGE ROOF LAYOUT
03/02/2021 LOT 91 FINAL
03/02/2021 I44738396_H3-91
03/02/2021 H3 #91 - Westport - Craftsman - Sheets- signed
03/03/2021 Approved Plans APPROVED PLANS
03/03/2021 Approved Plans APPROVED TRUSS DRAWINGS
03/03/2021 Approved Plans APPROVED TRUSS LAYOUT
03/03/2021 Plot Plan APPROVED PLOT PLAN
03/04/2021 Receipt Receipt for transaction:2021-001071
03/04/2021 Letter DS Building Permit
05/03/2021 Letter INSPECTION SUMMARY
05/03/2021 Letter Stop Work Order
05/03/2021 Lot 91 Hawthorne Ridge Footing Inspection
05/03/2021 Letter INSPECTION SUMMARY
05/03/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
08/02/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
11/05/2021 Letter INSPECTION SUMMARY
11/05/2021 Letter INSPECTION SUMMARY
11/10/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter Field Certificate of Occupancy
12/08/2021 Letter Codes Final Certificate of Occupancy
12/08/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home