Permit Application Status

PRRES20210880


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210880
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - TRUSS PACKAGE
03/02/2021
03/16/2021
09/01/2021
04/20/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/18/2021 03/16/2021
Kim Brennan
As-graded plot plan
Corrective Action Required
03/16/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 03/18/2021 03/16/2021
Kim Brennan
Plot Plan Review Rejected 03/04/2021 03/05/2021
Dylan Eppert
As-graded plot plan
Corrective Action Required
03/05/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 03/04/2021 03/05/2021
Dylan Eppert
Planning Review (RES) Approved 03/04/2021 03/02/2021
Victoria Nelson
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,627.22 $1,627.22 Paid 03/16/2021
8331507-Sewer Connection Fee $660.00 $660.00 Paid 03/16/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/16/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/16/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/16/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/16/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/07/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/07/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 02/07/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 02/07/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 4/23/2021 (9:15) 4/23/2021 04/23/2021
Misc
Corrective Action Required
04/23/2021
Column pad D plans shows 48 x 48 w/ 8 #4 bars EW chair up mats Column pad F calls for 10 # 4 bars EW chair up mats Provide sub grade report ( assumed 2000 PSF bearing to be verified by geotechnical engineer per plan ) Ufer location center of foundation wall rear of garage
Footing Inspection - Residential Passed 4/27/2021 04/27/2021
Misc
Resolved
04/27/2021
Ufer location center of foundation wall rear of garage
Misc
Informational
04/27/2021
3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL
Underslab Plumbing Inspection - Residential Passed 6/16/2021 6/15/2021 06/15/2021
All Rough Inspection - Residential Failed 8/17/2021 8/17/2021 08/17/2021
Misc
Resolved
10/21/2021
: PFH PORTAL FRAME ONLY : NAIL TOP PLATE TO HEADER W/ 16 SINKERS PER PLAN CHECK ABOVE ON ROUGH IN OK TO COVER EXTERIOR NO PLANS ON SITE FOR COVRED DECK FRONT PORCH NOT DONE
Sewer Service Inspection - R Passed 9/22/2021 (1:00) 9/22/2021 09/22/2021
Water Service Inspection - R Passed 9/24/2021 (9:45) 9/24/2021 09/24/2021
Erosion Control Inspection Residential Failed 10/21/2021 10/21/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/21/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - spread and maintain gravel filter -
Gas Service Inspection - Residential Failed 10/21/2021 10/21/2021 10/21/2021
Miscellaneous Correction
Corrective Action Required
10/21/2021
PROVIDE MIN 10 PSI FOR 15 MINUTES
Electrical Service Inspection Passed 10/21/2021 10/21/2021 10/21/2021
All Rough Inspection - Residential Failed 10/21/2021 10/21/2021 10/21/2021
Misc
Resolved
10/21/2021
: PFH PORTAL FRAME ONLY : NAIL TOP PLATE TO HEADER W/ 16 SINKERS PER PLAN CHECK ABOVE ON ROUGH IN OK TO COVER EXTERIOR NO PLANS ON SITE FOR COVRED DECK FRONT PORCH NOT DONE
Miscellaneous Correction
Corrective Action Required
10/21/2021
Fire block dead space & chase dining room Tighten anchor bolts garage Fire block furr outs garage Furr out HVAC for insulation garage Truss lock screw garage T19 near porch Solid block sheathing break landing near plant shelf Replace basement landing subfloor Address double floor joist cut near radon basement Address floor joist cut above furnace Provide joist hangers Mitch against stairway basement Fire block chase and soffit near patio door Address bores in LVL above refrigerator Fire block chase in pantry Address stud packs used in place of SCH 40 columns garage beam Replace LIB rear garage wall Fire block DWV bath 5 Provide solid security blocking patio door Replace stud bath 3 Snow blocking bed 3 Strap top plate bed 1 near shower Seal bad bore floor at tub Tran bath 2 Replace stud bath 4 Nail studs at intersecting wall corners per code Provide 4 studs at GT bearing points bath 4 & bath 2
Gas Service Inspection - Residential Passed 11/4/2021 11/4/2021 11/04/2021
Miscellaneous Correction
Resolved
11/04/2021
All Rough Inspection - Residential Not Ready 11/4/2021 11/4/2021 11/04/2021
Miscellaneous Correction
Corrective Action Required
10/21/2021
Fire block dead space & chase dining room Fire block furr outs garage Furr out HVAC for insulation garage Address double floor joist cut near radon basement ( CUT A DOUBLE REPLACED WITH SINGLE ) Fire block soffit near patio door Address bores in LVL above refrigerator ( DON'T SEE ENGINEER'S LETTER UPLOADED) Fire block chase in pantry FIRE BLOCK GAP AT BASEMENT SCH 40 columns garage beam Replace LIB rear garage wall Fire block DWV bath 5 Seal bad bore floor at tub Trap bath 2
All Rough Inspection - Residential Not Ready 11/9/2021 11/9/2021 11/09/2021
Miscellaneous Correction
Corrective Action Required
11/04/2021
Fire block dead space & chase dining room Fire block furr outs garage Furr out HVAC for insulation ( FIRE BLOCKING ) Fire block soffit near patio door Fire block chase in pantry Fire block DWV bath 5 ( 2018 IRC R302.11) Address bores in LVL above refrigerator ( DON'T SEE ENGINEER'S LETTER UPLOADED) LETTER DID NOT ADDRESS HVAC BORED THROUGH LVL ABOVE PANTRY DOOR
All Rough Inspection - Residential Failed 11/16/2021 11/16/2021 11/16/2021
Miscellaneous Correction
Corrective Action Required
11/09/2021
Address bores in LVL above refrigerator ( DON'T SEE ENGINEER'S LETTER UPLOADED) LETTER DID NOT ADDRESS HVAC BORED THROUGH LVL ABOVE PANTRY DOOR
All Rough Inspection - Residential Not Ready 11/22/2021 11/22/2021 11/22/2021
Miscellaneous Correction
Corrective Action Required
11/16/2021
Address bores in LVL above refrigerator ( DON'T SEE ENGINEER'S LETTER UPLOADED) LETTER DID NOT ADDRESS HVAC BORED THROUGH LVL ABOVE PANTRY DOOR - 11/22/21 PROVIDE DOUBLE LVL PER ENGINEERS LETTER/DRAWING SOUTH OF FURNACE IN BASEMENT -
Driveway Inspection Partial 11/23/2021 11/23/2021 11/23/2021
Misc
Informational
11/23/2021
Driveway was framed up with aggregate in and compacted.11/23 ES
Driveway Inspection Passed 12/3/2021 12/3/2021 12/03/2021
Misc
Informational
11/23/2021
Driveway was framed up with aggregate in and compacted.11/23 ES
Misc
Informational
12/03/2021
Driveway meets LS spec. RP 12-3-21
Erosion Control Inspection Residential Failed 12/7/2021 12/07/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/21/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - spread and maintain gravel filter -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/07/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GUTTER BUDDY - - CLEAN STREET & GUTTERS -
All Rough Inspection - Residential Passed 12/7/2021 12/7/2021 12/07/2021
Miscellaneous Correction
Resolved
12/07/2021
Piers/Caissons Inspection - Residential Passed 2/7/2022 (10:30) 2/7/2022 02/07/2022
Misc
Informational
02/07/2022
(2) 24 X 36 COVERED DECK PIERS
Erosion Control Inspection Residential Failed 3/1/2022 03/01/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/07/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - spread and maintain gravel filter -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/07/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GUTTER BUDDY - - CLEAN STREET & GUTTERS -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/01/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE UNTIL SOD COMPLETE ( STRAW WATTLE IN GUTTER ) CLEAN STREET MAINTAIN GUTTER BUDDY & REMOVE TRASH & DEBRIS BUILD UP AT CURB INLET MAINTAIN SILT FENCE AT FIELD INLET
Plot Plan Inspection Passed 3/1/2022 03/01/2022
Occupancy Inspection - Codes Residential Failed 3/1/2022 3/1/2022 03/01/2022
Miscellaneous Correction
Corrective Action Required
03/01/2022
SUBMIT BACKFLOW CERTIFICATION FOR LAWN IRRIGATION PERMIT PROVIDE SOD & SPLASH BLOCKS PROVIDE GUARDRAIL FRONT STOOP OR RAISE GRADE TO LESS THAN 30" PROVIDE HARDWARE FRONT DOOR REMOVE DUST COVERS SMOKE DETECTORS SUMP SHALL DISCHARGE 36" FROM FOUNDATION
Occupancy Inspection - Codes Residential Temporary C of O 3/7/2022 3/7/2022 03/07/2022
Miscellaneous Correction
Corrective Action Required
03/01/2022
SUBMIT BACKFLOW CERTIFICATION FOR LAWN IRRIGATION PERMIT PROVIDE SOD & SPLASH BLOCKS PROVIDE HARDWARE FRONT DOOR SUMP SHALL DISCHARGE 36" FROM FOUNDATION
Occupancy Inspection - Codes Residential Full C of O 4/20/2022 4/20/2022 04/20/2022
Miscellaneous Correction
Corrective Action Required
03/07/2022
PROVIDE SOD & SPLASH BLOCKS PROVIDE HARDWARE FRONT DOOR SUMP SHALL DISCHARGE 36" FROM FOUNDATION
Documents & Images
Date Uploaded File Type Document Name
03/02/2021 Application Form W0 #140 - Permit App
03/02/2021 LOT 140 FINAL
03/02/2021 W0 #140 - Prescott - Mediterranean - Sheets- signed
03/02/2021 2646256 RF SEALS 02152021
03/02/2021 140 WOODSIDE RIDGE TRUSS LAYOUT
03/04/2021 Specifications APPROVED TRUSS PACKAGE
03/04/2021 Drawing APPROVED TRUSS LAYOUT
03/05/2021 Approved Plans APPROVED HOUSE PLAN
03/05/2021 Letter Codes Residential Plan Review
03/09/2021 W0 #140 - REVISED Prescott - Mediterranean - Sheets- signed
03/09/2021 Approved Plans APPROVED REVISED HOUSE PLANS
03/16/2021 LOT 140 CITY
03/16/2021 Plot Plan Approved Plot Plan
03/16/2021 Receipt Receipt for transaction:2021-001306
03/16/2021 Letter DS Building Permit
04/23/2021 Letter INSPECTION SUMMARY
04/26/2021 Approved Plans Approved Revised Basement Plan
04/26/2021 Lot 140 Woodside Ridge footing inspection
04/27/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
08/17/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
11/09/2021 140 woodside ridge main and second floor framing revision letter
11/09/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter INSPECTION SUMMARY
11/16/2021 140 woodside ridge main and second floor framing revision letter 11-9
11/23/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/10/2021 W0 #140 - Prescott - Mediterranean - A1 - A3 REV 12-6-21 - signed
12/13/2021 Approved Plans APPROVED UPDATED PLANS
02/07/2022 Receipt Receipt for transaction:2022-000636
02/07/2022 Letter INSPECTION SUMMARY
02/24/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Plot Plan Approved As Graded Plot Plan
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Grade1
03/01/2022 grade2
03/01/2022 grade3
03/01/2022 grade4
03/01/2022 grade5
03/07/2022 Letter Codes Temporary Certificate of Occupancy
04/20/2022 Letter Field Certificate of Occupancy
04/20/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: