PRRES20210837
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
02/26/2021
03/30/2021
01/03/2022
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
TRUMARKHOMES.MARK@GMAIL.COM  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/08/2021 03/08/2021
Dylan Eppert
Planning Review (RES) Approved 03/08/2021 03/08/2021
Jennifer Thompson
Residential Plan Review Approved 03/08/2021 03/08/2021
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,221.68 $1,221.68 Paid 03/30/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 03/30/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/30/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/30/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/30/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/30/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/27/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/9/2021 04/09/2021
Misc
Informational
04/09/2021
UFER LOCATED FOUNDATION WALL FT STOOP/GARAGE
Underslab Plumbing Inspection - Residential Passed 5/14/2021 5/14/2021 05/14/2021
Misc
Informational
05/14/2021
PROVIDE ADDRESS
All Rough Inspection - Residential Partial 6/14/2021 6/14/2021 06/14/2021
Misc
Informational
06/14/2021
GARAGE PFH PORTAL FRAME HOLDDOWNS & 3" O.C. NAILING APPROVED OK TO COVER PROVIDE 2 ROWS 16D SINKER 3" O.C. TOP PLATE TO HEADER 5/8 ANCHOR SHALL BE IN MIDDLE 1/3 THE WIDTH OF PLATE CHECK ABOVE ON ROUGH IN
Piers/Caissons Inspection - Residential Passed 6/18/2021 (8:00) 6/18/2021 06/18/2021
Misc
Informational
06/18/2021
(2) 18 x 40 deck piers
Gas Service Inspection - Residential Failed 8/4/2021 8/4/2021 08/04/2021
Misc
Corrective Action Required
08/04/2021
NO GAS LINES PROVIDE GUAGE WITH MIIN 10 PSI
Electrical Service Inspection Failed 8/4/2021 8/4/2021 08/04/2021
Misc
Corrective Action Required
08/04/2021
IDENTIFY UFER GROUND BOTH ENDS UFER FRONT STOOP NEAR GARAGE ?
All Rough Inspection - Residential Failed 8/4/2021 8/4/2021 08/04/2021
Misc
Informational
06/14/2021
GARAGE PFH PORTAL FRAME HOLDDOWNS & 3" O.C. NAILING APPROVED OK TO COVER 5/8 ANCHOR SHALL BE IN MIDDLE 1/3 THE WIDTH OF PLATE CHECK ABOVE ON ROUGH IN
Misc
Corrective Action Required
08/04/2021
NO CITY APPROVED PLANS ON SITE
Gas Service Inspection - Residential Failed 8/6/2021 8/6/2021 08/06/2021
Misc
Corrective Action Required
08/04/2021
IDENTIFY GAS LINE BOND AT SERVICE PANEL
Electrical Service Inspection Failed 8/6/2021 8/6/2021 08/06/2021
Misc
Corrective Action Required
08/04/2021
IDENTIFY UFER GROUND BOTH ENDS, UFER GROUND REQUIRED, SEE LOCATION NOTED AT FOOTING, FOUNDATION WALL FT STOOP/GARAGE
All Rough Inspection - Residential Failed 8/6/2021 8/6/2021 08/06/2021
Misc
Informational
08/04/2021
GARAGE PFH PORTAL FRAME HOLDDOWNS & 3" O.C. NAILING APPROVED OK TO COVER 5/8 ANCHOR SHALL BE IN MIDDLE 1/3 THE WIDTH OF PLATE CHECK ABOVE ON ROUGH IN
Misc
Corrective Action Required
08/04/2021
-seal gas line floor penetration at fireplace -nail rafters to joists front bedroom -fireblock unused bore at top plate, front bath 1st floor -lvl master closet per plans -submit engineer letter concerning change from lvl ridge beam to steel ridge beam at great room -tighten all anchor bolts at basement, anchor bolts required within 12” of plate breaks and in middle third of plate -security blocking basement hinge side walkout -fireblock between top plates at finished basement bath north wall -shim stud pack at steel ridge beam at fireplace so stud pack rests on all (3) lvl -fireblock at soffit DWV basement bath north -dead end air return at finished bakery north bedroom -pan off air return at furred down In finished basement den ceiling -secure/support Ward flex gas and NM at furred down in basement -nail exterior sheathing per plans
Gas Service Inspection - Residential Passed 8/10/2021 8/10/2021 08/10/2021
Misc
Resolved
08/10/2021
Electrical Service Inspection Failed 8/10/2021 8/10/2021 08/10/2021
Misc
Corrective Action Required
08/06/2021
IDENTIFY UFER GROUND BOTH ENDS, UFER GROUND REQUIRED, SEE LOCATION NOTED AT FOOTING, FOUNDATION WALL FT STOOP/GARAGE - LOCATE UFER & GROUND SERVICE PANEL -
All Rough Inspection - Residential Not Ready 8/10/2021 8/10/2021 08/10/2021
Misc
Informational
08/06/2021
GARAGE PFH PORTAL FRAME HOLDDOWNS & 3" O.C. NAILING APPROVED OK TO COVER 5/8 ANCHOR SHALL BE IN MIDDLE 1/3 THE WIDTH OF PLATE ( not done) CHECK ABOVE ON ROUGH IN
Misc
Corrective Action Required
08/06/2021
: REMOVE INSULATION TO EXPOSE COVERED ITEMS : -nail rafters to joists front bedroom -lvl master closet per plans ( NO LVL) -submit engineer letter concerning change from lvl ridge beam to steel ridge beam at great room ( NO LETTER IN DOCUMENTS) -tighten all anchor bolts at basement, anchor bolts required within 12” of plate breaks and in middle third of plate ( insulation covered) -fireblock between top plates at finished basement bath north wall ( not done) -dead end air return at finished bakery north bedroom -pan off air return at furred down In finished basement den ceiling -secure/support NM at furred down in basement
Electrical Service Inspection Failed 8/12/2021 8/12/2021 08/12/2021
Misc
Corrective Action Required
08/10/2021
IDENTIFY UFER GROUND BOTH ENDS, UFER GROUND REQUIRED, SEE LOCATION NOTED AT FOOTING, FOUNDATION WALL FT STOOP/GARAGE - LOCATE UFER & GROUND SERVICE PANEL - - UFER LOCATION NOTED ON FOOTING INSPECTION FIND IT Michael Harkins 08/12/2021 9:54 AM
All Rough Inspection - Residential Failed 8/12/2021 8/12/2021 08/12/2021
Misc
Informational
08/10/2021
GARAGE PFH PORTAL FRAME HOLDDOWNS & 3" O.C. NAILING APPROVED OK TO COVER
Misc
Corrective Action Required
08/10/2021
-lvl master closet per plans ( NO LVL) 2 X 6 JOIST DOUBLED UP PER DAVID AINSWORTH LETTER ( NO LETTER IN DOCUMENTS ) -submit engineer letter concerning change from lvl ridge beam to steel ridge beam at great room ( NO LETTER IN DOCUMENTS) UPLOAD ENGINEER LETTERS TO PERMIT SO ALL INSPECTORS HAVE ACCESS OK TO ROCK
Sewer Service Inspection - R Passed 9/7/2021 9/7/2021 09/07/2021
Water Service Inspection - R Passed 9/10/2021 (10:15) 9/10/2021 09/10/2021
Driveway Inspection Partial 10/6/2021 10/6/2021 10/06/2021
Misc
Informational
10/06/2021
Forms are in place and aggregate is present and compacted.
Sidewalk Inspection Partial 10/6/2021 10/6/2021 10/06/2021
Misc
Informational
10/06/2021
Forms are in place and aggregate is present and compacted. Had crew adjust part of the form because is was over 2%
Sidewalk Inspection Passed 10/15/2021 10/15/2021 10/12/2021
Misc
Informational
10/06/2021
Forms are in place and aggregate is present and compacted. Had crew adjust part of the form because is was over 2%
Misc
Informational
10/12/2021
10-12-21 AN sidewalk looks good and meets ADA specs
Driveway Inspection Passed 10/15/2021 10/15/2021 10/12/2021
Misc
Informational
10/06/2021
Forms are in place and aggregate is present and compacted.
Misc
Informational
10/12/2021
10-12-21 AN driveway looks good and has expansion joints at curb and right of way and meets ADA spec
Electrical Service Inspection Failed 10/20/2021 10/20/2021 10/20/2021
Misc
Corrective Action Required
08/12/2021
IDENTIFY UFER GROUND BOTH ENDS, UFER GROUND REQUIRED, SEE LOCATION NOTED AT FOOTING, FOUNDATION WALL FT STOOP/GARAGE - LOCATE UFER & GROUND SERVICE PANEL - - UFER LOCATION NOTED ON FOOTING INSPECTION FIND IT Michael Harkins 08/12/2021 9:54 AM ( 2018 IRC E3608.1.2)
Misc
Corrective Action Required
10/20/2021
email sent to Mark : locate the CCE and reschedule for inspection.
Electrical Service Inspection Passed 11/2/2021 11/2/2021 11/02/2021
Misc
Resolved
11/02/2021
IDENTIFY UFER GROUND BOTH ENDS, UFER GROUND REQUIRED, SEE LOCATION NOTED AT FOOTING, FOUNDATION WALL FT STOOP/GARAGE - LOCATE UFER & GROUND SERVICE PANEL - - UFER LOCATION NOTED ON FOOTING INSPECTION FIND IT Michael Harkins 08/12/2021 9:54 AM ( 2018 IRC E3608.1.2)
Misc
Resolved
11/02/2021
CONCRETE ENCASED ELECTRODE IN MECHANICAL ROOM NEAR FRONT STOOP
Occupancy Inspection - Codes Residential Failed 12/29/2021 12/29/2021 12/29/2021
Misc
Corrective Action Required
12/29/2021
-hand rail required at garage entry steps -ufer ground to be accessible -label all non GFCI outlets in unfinished spaces -mini split to be of correct breaker size -splash blocks and sump pump discharge to extend 36" from foundation see NW corner
All Rough Inspection - Residential Passed 1/3/2022 01/03/2022
Misc
Informational
08/12/2021
GARAGE PFH PORTAL FRAME HOLDDOWNS & 3" O.C. NAILING APPROVED OK TO COVER
Misc
Resolved
01/03/2022
Plot Plan Inspection Passed 1/3/2022 01/03/2022
Occupancy Inspection - Codes Residential Full C of O 1/3/2022 01/03/2022
Misc
Resolved
01/03/2022
Documents & Images
Date Uploaded File Type Document Name
02/26/2021 Application Form SKM_C36821022615410
03/04/2021 69 woodside plot plan
03/04/2021 69 woodside Sealed Prints
03/08/2021 Plot Plan APPROVED PLOT PLAN
03/08/2021 Approved Plans APPROVED HOUSE PLAN
03/30/2021 Receipt Receipt for transaction:2021-001597
03/30/2021 Letter DS Building Permit
04/09/2021 Letter INSPECTION SUMMARY
05/14/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Mark Yancik 2038 NW O Brien LSMO Woodbridge Ridge Lot 69 Framing Issues Inspection Report 8-11-21
09/07/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/12/2021 Letter INSPECTION SUMMARY
10/12/2021 Letter INSPECTION SUMMARY
10/20/2021 Letter INSPECTION SUMMARY
11/02/2021 Letter INSPECTION SUMMARY
12/27/2021 Receipt Receipt for transaction:2021-009476
12/29/2021 Letter INSPECTION SUMMARY
01/03/2022 Letter INSPECTION SUMMARY
01/03/2022 Letter INSPECTION SUMMARY
01/03/2022 Letter Field Certificate of Occupancy
01/03/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home