PRRES20210774


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210774
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - DETACHED GARAGE/CARRIAGE HOUSE WITH LIVING SPACE ABOVE GARAGE
02/24/2021
03/03/2021
06/08/2022
Locations
Contacts
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
BELLAH HOMES LLC, Address:P O BOX 346, Phone:(816) 697-2870  
TROY@BELLAHHOMES.COM  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/02/2021 03/03/2021
Brandon Kalwei
Residential Plan Review Approved 03/02/2021 03/01/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,065.26 $1,065.26 Paid 03/03/2021
8331507-Sewer Connection Fee $630.00 $630.00 Paid 03/03/2021
Right of Way Permit Fee $80.00 $80.00 Paid 03/03/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/02/2021
$1,077.12
Water Tap Fee $3,581.00 $3,581.00 Paid 03/03/2021
Water Meter Fee $455.54 $455.54 Paid 03/03/2021
New Longview Road and Bridge Escrow $1,077.12 $1,077.12 Paid 03/03/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 4/23/2021 4/23/2021 04/23/2021
Water Service Inspection - R Passed 5/6/2021 (1:00) 5/6/2021 05/06/2021
Footing Inspection - Residential Passed 5/6/2021 05/06/2021
Water Service Inspection - R Passed 5/7/2021 (8:00) 5/7/2021 05/07/2021
Underground Plumbing Inspection - Residential Passed 5/7/2021 05/07/2021
Misc
Informational
05/07/2021
Underground water distribution piping and DWV from dwelling to accessory structure approved
Sewer Service Inspection - R Passed 5/7/2021 (8:00) 5/7/2021 05/07/2021
All Rough Inspection - Residential Failed 9/28/2021 9/28/2021 09/28/2021
Misc
Corrective Action Required
09/28/2021
DETACHED GARAGE&DWELLING: -Fb plumbing space from joist and soffit space -Anchor sill plate within 12” of break; anchors must be within middle 1/3 of sill plate -Fb penetrations of wall plates -Cap off unused drain pipe under kitchen sink -Complete electrical supply to detached building. Provide grounding electrode system for detached building (I don’t see any ufer), isolate grounded and grounding conductors, and provide grounding per code -Provide security blocking for exterior door per security code **OK TO INSULATE **Waste clean out and water valve must be accessible at final MAIN DWELLING BUILDING: -Seal penetrations of return air space -Fb stud space from joist space at stair landing ceiling level; Fb b-vent/duct chase from joist space -Provide 6 stud support for I beam at master bedroom/kitchen wall -Nail joist hangers above doorway to master bedroom -3 stud support at stair in basement per plan -Fb all floor penetrations -Install hangers at joist connections to header above basement window -At service panel, connect the #6 bonding conductor to the equipment grounding bus bar -Provide framing per code above basement laundry area or have engineer address -Install min 4 stud support for I beam point load near main duct in basement -Remove all construction debris from attic space -Brace ceiling joists above foyer/great room -Support rafters at beam connections above 2nd fl bathroom with hangers **OK TO INSULATE
Electrical Service Inspection Passed 9/28/2021 9/28/2021 09/28/2021
Gas Service Inspection - Residential Passed 9/28/2021 9/28/2021 09/28/2021
All Rough Inspection - Residential Failed 10/1/2021 10/1/2021 10/01/2021
Misc
Corrective Action Required
09/28/2021
DETACHED GARAGE&DWELLING: -Anchor sill plate within 12” of break; anchors must be within middle 1/3 of sill plate -Complete electrical supply to detached building. Provide grounding electrode system for detached building (I don’t see any ufer), isolate grounded and grounding conductors, and provide grounding per code **OK TO INSULATE **Waste clean out and water valve must be accessible at final MAIN DWELLING BUILDING: -Fb b-vent/duct chase from joist space **remove wood from within 1” of b-vent -At service panel, connect the #6 bonding conductor to the equipment grounding bus bar **not the grounded bus bar -Provide framing per code above basement laundry area or have engineer address **To rectify this problem, you can extend the header joist near basement dryer duct to be supported by the stair wall. Connect all other joists with proper hangers for 2x10 **OK TO INSULATE
All Rough Inspection - Residential Failed 10/5/2021 10/5/2021 10/05/2021
Misc
Corrective Action Required
10/01/2021
DETACHED GARAGE&DWELLING: -Complete electrical supply to detached building. Provide grounding electrode system for detached building (I don’t see any ufer), isolate grounded and grounding conductors, and provide grounding per code
All Rough Inspection - Residential Passed 10/19/2021 10/19/2021 10/19/2021
Misc
Resolved
10/19/2021
DETACHED GARAGE&DWELLING: -Complete electrical supply to detached building. Provide grounding electrode system for detached building (I don’t see any ufer), isolate grounded and grounding conductors, and provide grounding per code
Sidewalk Inspection Partial 12/13/2021 12/13/2021 12/13/2021
Misc
Informational
12/13/2021
Sidewalk was framed up with aggregate in and compacted. 12/13 ES
Sidewalk Inspection Passed 12/17/2021 12/17/2021 12/17/2021
Misc
Informational
12/13/2021
Sidewalk was framed up with aggregate in and compacted. 12/13 ES
Misc
Informational
12/17/2021
Sidewalk meets LS and Ada spec. 12/17/21 ES
Erosion Control Inspection Residential Failed 02/14/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/14/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 2/14/2022 2/14/2022 02/14/2022
Miscellaneous Correction
Corrective Action Required
02/14/2022
- Maintain erosion control - Driveway inspection incomplete - install irrigation system - Complete gutters - Final grading and sod - Provide ladder for both basement Egress windows - Seal top of meter can - Seal top of A/C disconnect - Seal penetration on exterior - Sump discharge 36” from foundation - Break off set screw on back flow device in garage - Make access panel for water and sewer in garage - Add missing joist hangers garage landing - Connect water heater in apartment over garage
Occupancy Inspection - Codes Residential Temporary C of O 2/22/2022 2/22/2022 02/22/2022
Miscellaneous Correction
Corrective Action Required
02/14/2022
- Maintain erosion control - Driveway inspection incomplete - install irrigation system - Final grading and sod
Erosion Control Inspection Residential Failed 05/24/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/14/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Misc
Corrective Action Required
05/24/2022
Erosion control needs repaired around property, silt socks in front are not adequate to stop/block flow of silt/mud into roadway. 5/24/22 ES
Erosion Control Inspection Residential Passed 6/8/2022 06/08/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/08/2022
Misc
Resolved
06/08/2022
Plot Plan Inspection Passed 6/8/2022 06/08/2022
Occupancy Inspection - Codes Residential Full C of O 6/8/2022 6/8/2022 06/08/2022
Miscellaneous Correction
Resolved
06/08/2022
Documents & Images
Date Uploaded File Type Document Name
02/24/2021 Application Form APPLICATION
02/24/2021 Application Form excise tax
02/26/2021 Lot91PlotPlan
02/26/2021 BHPPergolaNorthhamptonLot91Sealed
03/01/2021 Approved Plans APPROVED PLANS
03/03/2021 Plot Plan APPROVED PLOT PLAN
03/03/2021 Receipt Receipt for transaction: 2021-001054
03/03/2021 Letter DS Building Permit
04/07/2021 M L Crose 1024 SW Armie St LSMO Pergola Park Lot 91 Bellah P 2021-0774 3rd Party Footing Inspection 4-6-21
04/23/2021 Letter INSPECTION SUMMARY
05/06/2021 Letter INSPECTION SUMMARY
05/06/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter INSPECTION SUMMARY
10/13/2021 1024 SW Armie Street - Structural Letter (October 12, 2021)[3281]
10/19/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter Codes Temporary Certificate of Occupancy
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter Codes Final Certificate of Occupancy
06/08/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home