PRRES20210595
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK- ROOF TRUSS STOP WORK ORDER generated on 04/16/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 04/19/2021 12:00 AM by username 'Patrick Schonfeldt'.
02/12/2021
02/25/2021
08/15/2021
12/20/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/01/2021 02/25/2021
Kim Brennan
Sidewalks
Corrective Action Required
02/25/2021

Sidewalks with dimensions must be provided on the plot plan.
Residential Plan Review Approved 03/01/2021 02/25/2021
Kim Brennan
Plot Plan Review Rejected 02/18/2021 02/16/2021
Kim Brennan
Sidewalks
Corrective Action Required
02/16/2021

Sidewalks with dimensions must be provided on the plot plan.
Residential Plan Review Approved 02/18/2021 02/16/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $899.41 $899.41 Paid 02/25/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/25/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/25/2021
8331504-EFHB Middle Big Creek, Full $401.76 $401.76 Paid 02/25/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 02/25/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/25/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/25/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed - Stop Work 4/16/2021 4/16/2021 04/16/2021
Misc
Corrective Action Required
04/16/2021
-FOOTING POURED WITHOUT INSPECTION, SUBMIT ENGINEER REPORT, REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 2 DAYS OF INSPECTION
Footing Inspection - Residential Passed 4/19/2021 04/19/2021
Misc
Resolved
04/19/2021
Underslab Plumbing Inspection - Residential Failed 5/5/2021 5/5/2021 05/05/2021
Misc
Corrective Action Required
05/05/2021
INTERIOR DRAIN TILE - IF STRETCHING DIAGONALLY ACROSS UNDERSLAB, IT MUST GO DIAGONALLY FROM SUMP PIT TO OPPOSITE CORNER AND REACH FOOTING
Underslab Plumbing Inspection - Residential Passed 5/7/2021 5/7/2021 05/07/2021
Misc
Resolved
05/07/2021
All Rough Inspection - Residential Failed 5/27/2021 5/27/2021 05/27/2021
Misc
Corrective Action Required
05/27/2021
**APPROVED TRUSS PLANS/DRAWINGS REQUIRED ON SITE IF INSPECTING PORCH/DECK TRUSSES AT SAME TIME AS GARAGE PORTAL** **GARAGE PORTAL 5/27/21** - SEE IRC R602.10.6.2 -NAIL HOLD DOWN STRAPS EMBEDDED IN CONCRETE TO SHEATHING -PANEL SPLICES EDGES SHALL OCCUR OVER AND BE NAILED TO COMMON BLOCKING WITHIN THE MIDDLE 24" OF THE PORTAL LEG. ONE ROW OF 3" O.C. NAILING REQ EACH SIDE PANEL
All Rough Inspection - Residential Partial 6/25/2021 6/25/2021 06/25/2021
Misc
Informational
06/25/2021
-6/25/21 - INSPECTED GARAGE PORTAL AND COVERED PORCH, DECK TRUSSES, OK TO COVER
Electrical Service Inspection Passed 7/22/2021 7/22/2021 07/22/2021
Gas Service Inspection - Residential Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/22/2021
-Gas pressure at 0 PSI, must maintain 10 PSI for test
All Rough Inspection - Residential Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/22/2021
-Attic access requires 30” vertical clearance height -Fireblock between top plates at fur out at garage wall -Fireblock HVAC/B vent chase laundry -seal top plate penetration- see pantry, basement penetrations in fireblock, basement stair wall -12” oc nailing at all abutting and intersecting wall corners -LIB bracing all locations per plans -see garage,bed#2 closet -Anchor bolt required with 12” of plate break bottom plate at basement -Properly support basement stair landing -Electrical receptacle required within 25’ of furnace in basement -DBL 2x10 joists under kitchen island with solid blocking between joists every 48”oc per plans -Provide engineer letter on rec room windows, dbl top plate removed at (3) 2x10 header with ends or top plate strapped to smart siding trim -Fireblock bump out for plumbing at top plate basement bath#3 -(2) 1/2” through bolts at each post/beam connection at deck
Gas Service Inspection - Residential Passed 7/28/2021 7/28/2021 07/28/2021
Misc
Resolved
07/28/2021
All Rough Inspection - Residential Failed 7/28/2021 7/28/2021 07/28/2021
Misc
Corrective Action Required
07/22/2021
-seal penetrations in fireblock between top plate basement south wall -LIB bracing all locations per plans -see garage -Complete plumbing that was removed for correction of dbl floor joists at kitchen island
All Rough Inspection - Residential Passed 8/2/2021 8/2/2021 08/02/2021
Misc
Resolved
08/02/2021
Sewer Service Inspection - R Passed 8/16/2021 08/16/2021
Water Service Inspection - R Passed 8/17/2021 08/17/2021
Sidewalk Inspection Passed 9/9/2021 09/10/2021
Misc
Informational
09/10/2021
On Thursday September 9, 2021 I performed a sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 9/9/2021 09/10/2021
Misc
Informational
09/10/2021
On Thursday September 9, 2021 I performed a driveway inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Failed 10/22/2021 10/22/2021 10/22/2021
Misc
Corrective Action Required
10/22/2021
*obtain sprinkler permit * -Add splash blocks and extend sump pump discharge 36” from foundation -A/c breaker incorrect size -meter need be 14”-18” lid to lid -provide 6” between siding and grade
Occupancy Inspection - Codes Residential Failed 11/2/2021 11/2/2021 11/02/2021
Misc
Corrective Action Required
10/22/2021
-water meter need be 14”-18” lid to lid -A/c breaker incorrect size -provide 6” between siding and grade
Occupancy Inspection - Codes Residential Failed 12/17/2021 12/17/2021
Misc
Corrective Action Required
11/02/2021
-A/c breaker incorrect size max 30
Plot Plan Inspection Passed 12/20/2021 12/20/2021
Erosion Control Inspection Residential Passed 12/20/2021 12/20/2021
Piers/Caissons Inspection - Residential Passed 12/20/2021 12/20/2021
Misc
Informational
12/20/2021
addressed in 3rd party footing inspection.
Occupancy Inspection - Codes Residential Full C of O 12/20/2021 12/20/2021 12/20/2021
Misc
Resolved
12/20/2021
-A/c breaker incorrect size max 30
Documents & Images
Date Uploaded File Type Document Name
02/12/2021 Application Form MN #87 - PERMIT APPLICATION
02/16/2021 Approved Plans Approved Drawings
02/16/2021 Approved Plans Approved Truss Layout
02/16/2021 Approved Plans Approved Truss Package
02/16/2021 Letter Codes Residential Plan Review
02/25/2021 Plot Plan Approved Plot Plan
02/25/2021 Receipt Receipt for transaction:2021-000925
02/25/2021 Letter DS Building Permit
04/16/2021 Letter Stop Work Order
04/16/2021 Lot 87 Stoney Creek Footing inspection
04/16/2021 Lot 87 Stoney Creek Foundation Inspection
04/19/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
05/27/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/23/2021 Everstead Engineer letter
07/28/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
08/02/2021 Letter INSPECTION SUMMARY
08/17/2021 Letter INSPECTION SUMMARY
08/17/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
10/25/2021 MN87 sprinkler permit
11/02/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter Field Certificate of Occupancy
12/20/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home