Permit Application Status

PRRES20210556


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210556
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT (permit update, partial finished basement added 8/23/21) - COVERED DECK
02/09/2021
02/10/2021
08/09/2021
09/01/2022
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/12/2021 02/10/2021
Brandon Kalwei
Legal description
Corrective Action Required
02/10/2021

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. Street address is wrong on plot plan compared to plans.
Drainage swales/berms
Corrective Action Required
02/10/2021

Drainage swales/berms: provide cross-section elevations as required to conform to the accepted "As graded" Master Drainge Plan (MDP), include cross-section detail from MDP. MDP shows that there should be a swale between each of the lots 81-90 to drain towards roadway
As-graded plot plan
Corrective Action Required
02/10/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 02/12/2021 02/10/2021
Brandon Kalwei
Plot Plan Review Rejected 02/12/2021 02/10/2021
Brandon Kalwei
Legal description
Corrective Action Required
02/10/2021

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. Street address is wrong on plot plan compared to plans.
Drainage swales/berms
Corrective Action Required
02/10/2021

Drainage swales/berms: provide cross-section elevations as required to conform to the accepted "As graded" Master Drainge Plan (MDP), include cross-section detail from MDP. MDP shows that there should be a swale between each of the lots 81-90 to drain towards roadway
As-graded plot plan
Corrective Action Required
02/10/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 02/12/2021 02/10/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,416.16 $1,416.16 Paid 02/10/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 02/10/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/10/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/10/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/10/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/10/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/3/2021 (2:45) 3/3/2021 03/03/2021
Misc
Informational
03/03/2021
UFER NORTH FOUNDATION WALL
Piers/Caissons Inspection - Residential Passed 3/3/2021 03/04/2021
Misc
Informational
03/04/2021
- POURED FOUNDATION WALL ON FOOTINGS INLO DECK PIERS -
Erosion Control Inspection Residential Failed 4/21/2021 04/21/2021
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
04/21/2021
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. MAINTAIN SILT FENCE
Underslab Plumbing Inspection - Residential Passed 4/21/2021 4/21/2021 04/21/2021
Sewer Service Inspection - R Passed 7/28/2021 (8:45) 7/28/2021 07/28/2021
Water Service Inspection - R Passed 7/29/2021 (1:15) 7/29/2021 07/29/2021
All Rough Inspection - Residential Failed 9/3/2021 9/3/2021 09/03/2021
Misc
Corrective Action Required
09/03/2021
NO ACCESS, NO LOCKBOX CODE, LOCKED UP, NO PFH PORTAL FRAME INSPECTION Michael Harkins 09/03/2021 8:40 AM
All Rough Inspection - Residential Failed 9/13/2021 9/13/2021 09/13/2021
Misc
Corrective Action Required
09/03/2021
: PFH PORTAL FRAME INSPECTION ONLY : TIGHTEN 5/8 ANCHOR BOLT CHECK ON ALL ROUGH OK TO COVER
Electrical Service Inspection Passed 9/20/2021 9/20/2021 09/20/2021
Gas Service Inspection - Residential Passed 9/20/2021 9/20/2021 09/20/2021
All Rough Inspection - Residential Failed 9/20/2021 9/20/2021 09/20/2021
Misc
Corrective Action Required
09/13/2021
: PFH PORTAL FRAME INSPECTION : TIGHTEN 5/8 ANCHOR BOLT CHECK ON ALL ROUGH OK TO COVER
Miscellaneous Correction
Corrective Action Required
09/20/2021
INCOMPLETE SET OF PLANS ON SITE MISSING PAGE A-1 ELEVATIONS, A-5 ROOF PLAN NO INSPECTION PERFORMED
All Rough Inspection - Residential Failed 9/21/2021 9/21/2021 09/21/2021
Misc
Resolved
09/21/2021
: PFH PORTAL FRAME INSPECTION : TIGHTEN 5/8 ANCHOR BOLT CHECK ON ALL ROUGH OK TO COVER
Miscellaneous Correction
Corrective Action Required
09/20/2021
Tighten anchor bolts garage Provide nuts & washers anchor bolts garage Anchor bolts shall land in middle 1/3 the width of plate throughput Protect NM conductors garage Address stud spacing at East garage wal-over 16” at top Nail LIBs throughout Provide LIBs per plan throughout Address rafters landing on blocks Provide (2) studs under 2x10 joist bed #2 closet Provide (2) 2x6 ceiling joist per plan bed #2 office Provide stringer connectors at stairs per plan Provide CS-PF nailing/straps per plan dining room Provide solid blocking at sheathing breaks & nail per code gathering room , stairs Sheathing not connected to top plate at gathering room Provide structural strap at VTR at master tub Provide plumbing protection plate washing machine drain Complete kitchen hood at roof Joist hanger at joist above stairs Midpoint strap dwv 2” and smaller Bocca plate bottom plate at refrigerator (4) 2x4s at owner’s suite/ gathering (2) 2x4 at garage/shower (2) 2x4 at pantry/ garage Address only (3) bearing studs at beam in dining/ gathering Repair moisture barrier at stairwell Nail rafter to joist connection per code Nail sheathing bed 4 and 5 Nail corners and intersecting walls per code Rafter ties at all rafters not connected to joist at top plate ( Craig has ? where 9/30/21) Protection plate at nm bed 5 exterior wall Seal penetrations in top plate fur out wall at stairs Nail joist hangers at stairwell basement Anchor bottom plate basement per code Seal penetrations in stud cavities used as return air Seal top plate penetration north basement wall Complete blocking between joists at island 48” oc at island Complete solidd blocking between joists above beam near stairs and bath Nail (3) 2x10 joist basement Nail exterior sheathing per code
All Rough Inspection - Residential Failed 10/4/2021 10/4/2021 10/04/2021
Miscellaneous Correction
Corrective Action Required
09/21/2021
Sheathing not connected to top plate at gathering room Nail rafter to joist connection per code Nail corners and intersecting walls per code Rafter ties at all rafters not connected to joist at top plate Seal penetrations in stud cavities used as return air Nail (3) 2x10 joist basement Nail exterior sheathing per code
All Rough Inspection - Residential Failed 10/7/2021 10/7/2021 10/07/2021
Miscellaneous Correction
Corrective Action Required
10/04/2021
Sheathing not connected to top plate at gathering room- BLOCKS SHOULD BE NAILED TO STUDS AND SHEATHING NAILED TO BLOCKS, NOT BLOCKS FACE NAILED TO SHEATHING Rafter ties at all rafters not connected to joist at top plate -NOT ADDRESSED Seal penetrations in stud cavities used as return air-SEE MASTER BED/BATH WALL Nail (3) 2x10 joist basement -SEE UNFINISHED SPACE Nail exterior sheathing per code-SEE AT WINDOW WELL, MASTER BED WINDOW WALL, ELECTRICAL METER, GAS METER
All Rough Inspection - Residential Failed 10/12/2021 10/12/2021 10/12/2021
Miscellaneous Correction
Corrective Action Required
10/07/2021
3-LVL rafter shown on plans over stairs to ridge. only 2 installed. revise plans showing 2 or install the 3rd and support each end.
All Rough Inspection - Residential Passed 10/13/2021 10/13/2021
Miscellaneous Correction
Resolved
10/13/2021
3-LVL rafter shown on plans over stairs to ridge. only 2 installed. revise plans showing 2 or install the 3rd and support each end.
Driveway Inspection Partial 11/12/2021 11/12/2021 11/12/2021
Misc
Informational
11/12/2021
Driveway is framed up with aggregate in and compacted. Framing meets LS and ADA spec. 11/12 ES
Sidewalk Inspection Partial 11/12/2021 11/12/2021 11/12/2021
Misc
Informational
11/12/2021
Sidewalk is framed up with aggregate in and compacted. Framing meets LS and ADA spec. 11/12 ES
Driveway Inspection Failed 11/19/2021 11/19/2021 11/19/2021
Misc
Informational
11/12/2021
Driveway is framed up with aggregate in and compacted. Framing meets LS and ADA spec. 11/12 ES
Misc
Corrective Action Required
11/19/2021
Driveway meets LS and ADA spec. However, curb line needs patched in multiple locations. 11/19 ES
Sidewalk Inspection Failed 11/19/2021 11/19/2021 11/19/2021
Misc
Informational
11/19/2021
Sidewalk is framed up with aggregate in and compacted. 11/12 ES
Misc
Corrective Action Required
11/19/2021
Sidewalk meets LS and Ada spec. However, sidewalk has multiple panels that need replaced due to chipping or damage all panels marked with pink X need replaced. 11/19 ES
Occupancy Inspection - Codes Residential Failed 1/19/2022 1/19/2022 01/19/2022
Miscellaneous Correction
Corrective Action Required
01/19/2022
- Pantry door must be self closing and latch - Counter space both sides of fire place require outlet. E3901.4.1 - Remove Dust covering on smoke alarm upstairs middle bedroom - Provide steps for Egress window Handrail in garage not compliant with code R311.7.8.5 - Complete final grading and sod - Provide splash blocks
Occupancy Inspection - Codes Residential Temporary C of O 1/27/2022 1/27/2022 01/27/2022
Miscellaneous Correction
Corrective Action Required
01/19/2022
TCO UNTIL 3-24-22 -MAINTAIN EROSION CONTROL AT FRONT OF LOT UNTIL SOD IS IN PLACE -Sidewalk and driveway inspections still pending - Complete final grading and sod - Provide splash blocks
Occupancy Inspection - Codes Residential Temporary C of O 3/18/2022 03/18/2022
Miscellaneous Correction
Corrective Action Required
01/27/2022
TCO UNTIL 4-15-22 -MAINTAIN EROSION CONTROL AT FRONT OF LOT UNTIL SOD IS IN PLACE -Sidewalk and driveway inspections still pending - Complete final grading and sod - Provide splash blocks 3/18/22 NO SOD EXTENDED TCO UNTIL 4/15/22 Michael Harkins 03/18/2022 10:23 AM
Plot Plan Inspection Passed 5/10/2022 05/10/2022
Occupancy Inspection - Codes Residential Temporary C of O 5/10/2022 5/10/2022 05/10/2022
Miscellaneous Correction
Corrective Action Required
03/18/2022
TCO UNTIL 5-27-22 -Sidewalk and driveway inspections still pending - OBTAIN LAWN IRRIGATION PERMIT & SUBMIT BACK FLOW CERTIFICATION
Sidewalk Inspection Passed 8/26/2022 8/26/2022 08/26/2022
Misc
Informational
11/19/2021
Sidewalk is framed up with aggregate in and compacted. 11/12 ES
Misc
Informational
08/26/2022
Sidewalk meets LS and Ada spec. However, sidewalk has multiple panels that need replaced due to chipping or damage all panels marked with pink X need replaced. 11/19 ES Broken sidewalk panels have been replaced and sidewalk meets LS and ADA spec. 8/26/22 ES
Driveway Inspection Passed 08/26/2022
Misc
Informational
11/19/2021
Driveway is framed up with aggregate in and compacted. Framing meets LS and ADA spec. 11/12 ES
Misc
Informational
08/26/2022
Driveway meets LS and ADA spec. However, curb line needs patched in multiple locations. 11/19 ES Curb line has been patched and is acceptable. 8/25/22
Occupancy Inspection - Codes Residential Full C of O 9/1/2022 9/1/2022 09/01/2022
Miscellaneous Correction
Resolved
09/01/2022
Documents & Images
Date Uploaded File Type Document Name
02/09/2021 Application Form APPLICATION
02/10/2021 Letter Codes Residential Plan Review
02/10/2021 Plot Plan APPROVED PLOT PLAN
02/10/2021 Receipt Receipt for transaction:2021-000650
02/10/2021 Letter DS Building Permit
03/03/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
08/25/2021 Approved Plans APPROVED PLANS
09/03/2021 Letter INSPECTION SUMMARY
09/13/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
10/04/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/12/2021 Letter INSPECTION SUMMARY
10/12/2021 2021_10_12_20-142 Lot 84 Woodside Ridge_Apex EOR LVL Rafter Compliance Letter
10/12/2021 2021_10_12_20-142 Lot 84 Woodside Ridge_A5 Roof Plan
10/13/2021 Letter INSPECTION SUMMARY
11/12/2021 Letter INSPECTION SUMMARY
11/12/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter Codes Temporary Certificate of Occupancy
03/18/2022 Letter Codes Temporary Certificate of Occupancy
05/10/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter Codes Temporary Certificate of Occupancy
08/26/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter Field Certificate of Occupancy
09/01/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home