Permit Application Status

PRRES20210367


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210367
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
01/27/2021
02/18/2021
07/27/2021
10/12/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOSH@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/22/2021 02/18/2021
Kim Brennan
Residential Plan Review Approved 02/22/2021 02/18/2021
Kim Brennan
Planning Review (RES) Approved 02/01/2021 01/28/2021
Shannon McGuire
Plot Plan Review Rejected 02/01/2021 01/28/2021
Kim Brennan
Residential Plan Review Approved 02/01/2021 01/28/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $963.59 $963.59 Paid 02/18/2021
Right of Way Permit Fee $80.00 $80.00 Paid 02/18/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/18/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 02/18/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 02/18/2021
Water Meter Fee $455.54 $455.54 Paid 02/18/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 10/11/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 10/11/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/24/2021 (2:00) 3/24/2021 03/24/2021
Misc
Informational
03/24/2021
UFER LOACATED FOUNDATION WALL REAR OF GARAGE
Underslab Plumbing Inspection - Residential Passed 4/15/2021 4/15/2021 04/15/2021
Erosion Control Inspection Residential Failed 5/13/2021 05/13/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/13/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
Piers/Caissons Inspection - Residential Passed 5/13/2021 (10:30) 5/13/2021 05/13/2021
Misc
Informational
05/13/2021
(2) 24 X 36 W/ 4 # 4 VERT BARS PER PLAN
All Rough Inspection - Residential Failed 6/1/2021 6/1/2021 06/01/2021
Misc
Corrective Action Required
06/01/2021
PORTAL FRAME, PORCH, COVERED DECK ONLY GARAGE PFH PORTAL FRAME NAIL SHEATHING ABOVE OVERHEAD DOOR SOLID BLOCK SHEATHING BREAKS ABOVE OVERHEAD DOOR FASTEN TOP PLATE TO HEADER WITH 2 ROWS 16D SINKERSAT 3" OC PROVIDE TENSION STRAPS AT PFH PORTAL FRAME PER PLAN REAR DECK PROVIDE H 2.5S PER PLAN, PROVIDE TJC37 HANGERS PER PLAN FRONT PORCH OK TO COVER
Sewer Service Inspection - R Passed 6/17/2021 (1:00) 6/17/2021 06/17/2021
Water Service Inspection - R Passed 6/25/2021 (1:45) 6/25/2021 06/25/2021
Gas Service Inspection - Residential Failed 7/9/2021 7/9/2021 07/09/2021
Misc
Corrective Action Required
07/09/2021
PROVIDE MINIMUM 10 PSI FOR 15 MIN
Electrical Service Inspection Passed 7/9/2021 7/9/2021 07/09/2021
All Rough Inspection - Residential Failed 7/9/2021 7/9/2021 07/09/2021
Misc
Corrective Action Required
06/01/2021
PORTAL FRAME, PORCH, COVERED DECK ONLY GARAGE PFH PORTAL FRAME SOLID BLOCK SHEATHING BREAKS & NAIL ABOVE OVERHEAD DOOR FASTEN TOP PLATE TO HEADER WITH 2 ROWS 16D SINKERSAT 3" OC REAR DECK PROVIDE H 2.5S PER PLAN 3rd truss needs trusslock screw or H2.5 east side FRONT PORCH OK TO COVER
Miscellaneous Correction
Corrective Action Required
07/09/2021
Fire blocking fireplace lid Garage anchor bolts shall be in middle 1/3 the width of plate Nail studs at intersecting wall corners at braced wall panels Nail sheathing per code throughout Seal top HVAC chase laundry Fire block dryer vent Provide Boca plates master closet & master water closet Provide nail guard bed #2 electrical to range in corner
All Rough Inspection - Residential Passed 7/14/2021 7/14/2021 07/14/2021
Misc
Resolved
07/14/2021
PORTAL FRAME, PORCH, COVERED DECK ONLY GARAGE PFH PORTAL OK TO COVER REAR DECK ok to cover FRONT PORCH OK TO COVER
Miscellaneous Correction
Resolved
07/14/2021
Driveway Inspection Partial 7/19/2021 7/19/2021 07/19/2021
Misc
Informational
07/19/2021
The driveway has been formed and rocked was compacted. It is ready to be poured.
Sidewalk Inspection Partial 7/21/2021 7/21/2021 07/21/2021
Misc
Informational
07/21/2021
Forms were placed and aggregate was present and compacted. RP 7-21-21
Sidewalk Inspection Passed 7/30/2021 7/30/2021 07/30/2021
Misc
Informational
07/21/2021
Forms were placed and aggregate was present and compacted. RP 7-21-21
Misc
Informational
07/30/2021
Finished sidewalk meets LS and ADA specs. RP 7-30-21
Gas Service Inspection - Residential Failed 9/16/2021 9/16/2021 09/16/2021
Misc
Corrective Action Required
07/09/2021
PROVIDE MINIMUM 10 PSI FOR 15 MIN
Miscellaneous Correction
Corrective Action Required
09/16/2021
PROVIDE GUAGE WITH MINIMUM 10 PSI FOR 15 MINUTES FOR GAS SERVICE INSPECTION
Occupancy Inspection - Codes Residential Failed 9/16/2021 9/16/2021 09/16/2021
Miscellaneous Correction
Corrective Action Required
09/16/2021
Submit back flow certification Driveway inspection pending Raise manhole cover to grade Lower water meter lid to grade Remove dust cover smoke detector great room Provide handle & secondary lock SGD Seal exterior light fixtures Provide 6" clearance grade to wood siding ( 2018 IRC R317.1 (5) Install listed fixture or cover plate covered patio Sump shall discharge 36" from foundation Provide gutters & downspouts, splash blocks Provide gauge with minimum 10 PSI FOR 15 minutes for gas service test
Gas Service Inspection - Residential Passed 9/24/2021 9/24/2021 09/24/2021
Misc
Resolved
09/24/2021
Miscellaneous Correction
Resolved
09/24/2021
Occupancy Inspection - Codes Residential Not Ready 9/24/2021 9/24/2021 09/24/2021
Miscellaneous Correction
Corrective Action Required
09/16/2021
Driveway inspection pending Raise manhole cover to grade Lower water meter lid to grade Provide handle & secondary lock SGD Seal exterior light fixtures
Plot Plan Inspection Passed 9/30/2021 09/30/2021
Occupancy Inspection - Codes Residential Temporary C of O 9/30/2021 9/30/2021 09/30/2021
Miscellaneous Correction
Corrective Action Required
09/24/2021
Driveway inspection pending Seal exterior light fixtures Lower water meter lid to grade
Occupancy Inspection - Codes Residential Not Ready 10/5/2021 10/5/2021 10/05/2021
Miscellaneous Correction
Corrective Action Required
09/30/2021
Driveway inspection pending Seal exterior light fixtures PAY OUTSTANDING FEES
Driveway Inspection Passed 10/7/2021 10/7/2021 10/07/2021
Misc
Informational
07/19/2021
The driveway has been formed and rocked was compacted. It is ready to be poured.
Misc
Informational
10/07/2021
Driveway looks good and meets ADA spec 10-7-21 11:20 AN
Occupancy Inspection - Codes Residential Full C of O 10/12/2021 10/12/2021 10/12/2021
Miscellaneous Correction
Resolved
10/12/2021
Driveway inspection pending Seal exterior light fixtures PAY OUTSTANDING FEES
Documents & Images
Date Uploaded File Type Document Name
01/27/2021 Application Form Permit Application and License Tax Form
01/28/2021 Approved Plans Approved Drawings
01/28/2021 Approved Plans Approved Truss Layout
01/28/2021 Approved Plans Approved Truss Package
01/28/2021 Letter Codes Residential Plan Review
02/18/2021 Plot Plan Approved Plot Plan
02/18/2021 Receipt Receipt for transaction:2021-000783
02/18/2021 Letter DS Building Permit
03/01/2021 Scope of Work Statement - W2 #46
03/01/2021 W2 #46 - Revised Carbondale - Tuscan - Sheets- signed
03/01/2021 Approved Plans APPROVED PLANS
03/24/2021 Letter INSPECTION SUMMARY
04/15/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
06/01/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/14/2021 Letter INSPECTION SUMMARY
07/19/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter Codes Temporary Certificate of Occupancy
10/05/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/11/2021 Receipt Receipt for transaction:2021-007882
10/12/2021 Letter Codes Final Certificate of Occupancy
10/13/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: