Permit Application Status

PRRES20210348


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210348
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - FINISHED BASEMENT STOP WORK ORDER generated on 03/31/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 04/01/2021 12:00 AM by username 'Patrick Schonfeldt'.
01/26/2021
01/29/2021
07/27/2021
12/10/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 02/02/2021 01/29/2021
Dylan Eppert
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
01/29/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) MISSING COVERED DECK SQ FOOTGAE.
Plot Plan Review Approved 02/02/2021 01/29/2021
Dylan Eppert
Deck location
Corrective Action Required
01/29/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Plot Plan Review Rejected 01/28/2021 01/28/2021
Dylan Eppert
Deck location
Corrective Action Required
01/28/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Residential Plan Review Rejected 01/28/2021 01/28/2021
Dylan Eppert
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
01/28/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) MISSING COVERED DECK SQ FOOTAGE.
Planning Review (RES) Approved 01/28/2021 01/26/2021
Victoria Nelson
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $958.06 $958.06 Paid 01/29/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 01/29/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 01/29/2021
Water Meter Fee $455.54 $455.54 Paid 01/29/2021
Right of Way Permit Fee $80.00 $80.00 Paid 01/29/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/29/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 11/02/2021
3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 11/02/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 11/02/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 3/31/2021 3/31/2021 03/31/2021
Misc
Corrective Action Required
03/31/2021
NO INSPECTION PERFORMED -FOOTING POURED WITHOUT INSPECTION, SUBMIT ENGINEER REPORT, THIRD PARTY ENGINEER REPORT REQUIRED TO BE SUBMITTED TO PERMIT WITHIN (2) DAYS OF INSPECTION -
Footing Inspection - Residential Failed - Stop Work 3/31/2021 3/31/2021 03/31/2021
Misc
Corrective Action Required
03/31/2021
-FOOTING POURED WITHOUT INSPECTION, SUBMIT ENGINEER REPORT, THIRD PARTY ENGINEER REPORT REQUIRED TO BE SUBMITTED TO PERMIT WITHIN (2) DAYS OF INSPECTION -
Footing Inspection - Residential Passed 4/1/2021 4/1/2021 04/01/2021
Misc
Resolved
04/01/2021
Underslab Plumbing Inspection - Residential Passed 4/7/2021 4/7/2021 04/07/2021
Misc
Resolved
04/07/2021
All Rough Inspection - Residential Partial 6/10/2021 6/10/2021 06/10/2021
Misc
Informational
06/10/2021
-EXTERIOR PORTAL FRAMING AND DECK TRUSSES OK TO COVER -INTERIOR AT PFH: PROVIDE TWO ROWS 16D SINKER NAILS 3' OC AT TOP PLATE TO HEADER-CHECK ON ALL ROUGH
Sewer Service Inspection - R Passed 6/24/2021 (8:45) 6/24/2021 06/24/2021
All Rough Inspection - Residential Failed 6/25/2021 6/25/2021 06/25/2021
Misc
Informational
06/10/2021
-INTERIOR AT PFH: PROVIDE TWO ROWS 16D SINKER NAILS 3' OC AT TOP PLATE TO HEADER -seal all top plate penetrations - see garage, 1st floor hall bath -strap top plate above garage entry to mud room -strap dbl top plate throughout with end joints offset less than 24" -seal all through floor penetrations -Dining room windows and basement rec room windows wall bracing requires 15/32” osb with 8D nails at 6” edge 12” field, blocking at base, mid height and top of windows - see plans -(1) ply of trpl truss girder not supported by top plate at corner above basement stairs -Anchor bolts required within 12” of plate break in basement -Fireblock vertical to horizontal at furred down soffit ends basement -2x4 laid flat at furred downs in finished basement 3’ or more must be connected to floor joist above to support the ceiling load -seal gap at fireblock top plate around DWV basement bath -complete bath exhaust fan duct at finished basement -Install basement egress window bed#4 -complete bath DWV, see above bedroom closet finished basement -Color code GEC at service panel -B vent at furnace requires 1” clearance from combustibles, move NM off vent -Anchor all steel columns to floor in basement -solid block between floor joists every 48” oc for kitchen island per plans -Install straps for CS-PF design at basement sliding glass door per plans -basement bed#4 egress window requires (2) 2x10 header -(2) 1/2” through bolts required at each post/beam connection at deck -Nail all exterior sheathing per plans
Water Service Inspection - R Passed 6/29/2021 (11:30) 6/29/2021 06/29/2021
Electrical Service Inspection Passed 7/13/2021 7/13/2021 07/13/2021
Gas Service Inspection - Residential Failed 7/13/2021 7/13/2021 07/13/2021
Misc
Corrective Action Required
07/13/2021
-Gas pressure at 0 psi, must maintain 10 psi for test
All Rough Inspection - Residential Failed 7/13/2021 7/13/2021 07/13/2021
Misc
Corrective Action Required
07/13/2021
-seal all top/bottom plate penetrations - see garage, 1st floor hall bath, 1st floor front bed -strap dbl top plate throughout with end joints offset less than 24" -see kitchen exterior wall -Anchor bolts required within 12” of plate break in basement -Fireblock vertical to horizontal at furred down soffit ends basement -fireblock around HVAC duct S wall bed -seal gap at fireblock top plate around DWV basement bath -complete bath DWV, see above bedroom closet finished basement -B vent at furnace requires 1” clearance from combustibles, move NM off vent -Install straps for CS-PF design at basement sliding glass door per plans -Install proper straps per code and nailed to header -(2) 1/2” through bolts required at each post/beam connection at deck -connection per code is post to beam not post to joist **DO NOT INSULATE**
All Rough Inspection - Residential Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/13/2021
-B vent at furnace requires 1” clearance from combustibles, move NM off vent - see behind furnace in basement
All Rough Inspection - Residential Passed 7/27/2021 7/27/2021 07/27/2021
Misc
Resolved
07/27/2021
Gas Service Inspection - Residential Failed 7/27/2021 7/27/2021 07/27/2021
Misc
Corrective Action Required
07/13/2021
-Gas pressure at 5 psi, must maintain 10 psi for test
Gas Service Inspection - Residential Not Ready 7/30/2021 7/30/2021 07/30/2021
Misc
Corrective Action Required
07/27/2021
-Gas pressure at 4 psi, must maintain 10 psi for test
Gas Service Inspection - Residential Passed 9/8/2021 9/8/2021 09/08/2021
Misc
Resolved
09/08/2021
Occupancy Inspection - Codes Residential Failed 10/26/2021 10/26/2021 10/26/2021
Misc
Corrective Action Required
10/26/2021
*PAY ALL FEES* -Driveway and sidewalk inspection need complete -Obtain sprinkler permit -outlet above fireplace need complete -GFCI required for dishwasher -label non GFCI outlet in all unfinished spaces -open/incomplete electrical junction box at back basement wall -complete secondary locking device on basement back sliding door -siding must be 6” from grade -provide splash blocks and sump pump discharge 36” from foundation -uncover MH Lid
Sidewalk Inspection Passed 7/22/2021 7/22/2021 11/03/2021
Misc
Informational
07/22/2021
7/22/21 14:03 - Sidewalk south of the driveway has the correct rock depth, correct depth for the forms, 5ft off the back of the curb, and is carrying the correct % throughout. **** Sidewalk NORTH of the drive had some issues, it had the correct depth of rock and forms, 5ft off the back of the curb, correct % thought out. *** At the property line of 2926 the gravel was pumping, they tried to dig it out but water kept coming in. I informed them they need to head it off and let it dry out and call in another inspector for the little of sidewalk left when it drys out. They are good to pour but 6ft or so to the property line of 2926. On Wednesday, 11-03-2021. I performed a visual inspection of the sidewalk at the property and found the sidewalk exceptable to pass inspection.
Driveway Inspection Passed 7/22/2021 7/22/2021 11/03/2021
Misc
Informational
07/22/2021
7/22/21 14:00 - Driveway is the correct depth, correct amount of rock has been installed, and the correct % is carried throughout for the sidewalk. On Wednesday,11-03-2021. I performed a visual inspection and passed the driveway inspection.
Plot Plan Inspection Passed 11/8/2021 11/08/2021
Occupancy Inspection - Codes Residential Temporary C of O 11/8/2021 11/8/2021 11/08/2021
Misc
Corrective Action Required
10/26/2021
TCO UNTIL 12/8/21 -Driveway and sidewalk inspection need complete -siding must be 6” from grade
Occupancy Inspection - Codes Residential Failed 11/16/2021 11/16/2021 11/16/2021
Misc
Corrective Action Required
11/08/2021
TCO UNTIL 12/8/21 -Driveway and sidewalk inspection need complete -siding must be 6” from grade see attached photos Mitchell Schwarz 11/16/2021 1:46 PM
Occupancy Inspection - Codes Residential Failed 12/3/2021 12/3/2021 12/03/2021
Misc
Corrective Action Required
11/16/2021
TCO UNTIL 12/8/21 -siding must be 6” from grade see attached photos Mitchell Schwarz 11/16/2021 1:46 PM -provide slope away from foundation at fix for above issue. Mitchell Schwarz 12/03/2021 9:09 AM
Occupancy Inspection - Codes Residential Temporary C of O 12/8/2021 12/08/2021
Misc
Corrective Action Required
12/03/2021
TCO UNTIL 12/8/21 -siding must be 6” from grade see attached photos Mitchell Schwarz 11/16/2021 1:46 PM -provide slope away from foundation at fix for above issue. Mitchell Schwarz 12/03/2021 9:09 AM
Misc
Informational
12/08/2021
TCO EXTENSION UNTIL 12/22/21
Erosion Control Inspection Residential Passed 12/10/2021 12/10/2021
Piers/Caissons Inspection - Residential Passed 12/10/2021 12/10/2021
Misc
Informational
12/10/2021
3RD PARTY INSPECTION SEE FOOTING REPORT
Occupancy Inspection - Codes Residential Full C of O 12/10/2021 12/10/2021 12/10/2021
Misc
Resolved
12/10/2021
TCO UNTIL 12/8/21 -siding must be 6” from grade see attached photos Mitchell Schwarz 11/16/2021 1:46 PM -provide slope away from foundation at fix for above issue. Mitchell Schwarz 12/03/2021 9:09 AM
Misc
Resolved
12/10/2021
TCO EXTENSION UNTIL 12/22/21
Documents & Images
Date Uploaded File Type Document Name
01/26/2021 Application Form H3 #7 - PERMIT APP
01/26/2021 7 HAWTHORNE RIDGE ROOF LAYOUT
01/26/2021 LOT 7 FINAL
01/26/2021 210251
01/26/2021 H3 #07 - Somerset - Craftsman - Sheets- signed
01/28/2021 Specifications APPROVED TRUSS PACKAGE
01/28/2021 Drawing APPROVED TRUSS LAYOUT
01/28/2021 Letter Codes Residential Plan Review
01/29/2021 Plot Plan APPROVED PLOT PLAN
01/29/2021 H3 #07 - Somerset - Craftsman - Revised for City
01/29/2021 Receipt Receipt for transaction:2021-000461
01/29/2021 Approved Plans APPROVED HOUSE PLAN
01/29/2021 Letter DS Building Permit
03/31/2021 Letter INSPECTION SUMMARY
03/31/2021 Letter Stop Work Order
03/31/2021 Lot 7 Hawthorn Ridge Footing Inspection
03/31/2021 Lot 7 Hawthorn Ridge Wall Inspection
04/01/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
06/10/2021 Letter INSPECTION SUMMARY
06/10/2021 Letter INSPECTION SUMMARY
06/24/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
06/29/2021 Letter INSPECTION SUMMARY
07/12/2021 7 Hawthorne Ridge Braced wall panels letter (003)
07/13/2021 Letter INSPECTION SUMMARY
07/13/2021 Letter INSPECTION SUMMARY
07/13/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter INSPECTION SUMMARY
11/02/2021 Receipt Receipt for transaction:2021-008440
11/03/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter Codes Temporary Certificate of Occupancy
11/08/2021 Letter INSPECTION SUMMARY
11/16/2021 2930 1
11/16/2021 2930 2
11/16/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/08/2021 TCO Extension request
12/08/2021 Letter Codes Temporary Certificate of Occupancy
12/10/2021 Letter Codes Final Certificate of Occupancy
12/10/2021 Letter Field Certificate of Occupancy
12/10/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home