Summary
PRRES20210266
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - UNFINISHED BASEMENT STOP WORK ORDER generated on 03/30/2021 12:00 AM by username 'Mark Harding'. STOP WORK ORDER removed on 03/30/2021 12:00 AM by username 'Michael Harkins'.
01/19/2021
01/26/2021
07/20/2021
10/12/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/28/2021 01/26/2021
Dylan Eppert
City infrustructure
Corrective Action Required
01/26/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. MISSING STORM INLET ON THE SIDE OF SHAMROCK AVE.
Residential Plan Review Approved 01/28/2021 01/26/2021
Dylan Eppert
Plot Plan Review Rejected 01/21/2021 01/21/2021
Dylan Eppert
City infrustructure
Corrective Action Required
01/21/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. MISSING STORM INLET ON THE SIDE OF SHAMROCK AVE.
Residential Plan Review Approved 01/21/2021 01/21/2021
Dylan Eppert
Planning Review (RES) Approved 01/21/2021 01/20/2021
Victoria Nelson
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,266.08 $1,266.08 Paid 01/26/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 01/26/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/26/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/26/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/26/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/26/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/11/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/11/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed - Stop Work 3/30/2021 3/30/2021 03/30/2021
Misc
Corrective Action Required
03/30/2021
Please add your contract name and cell number so the inspector can contact the builder. not Summit and 246-6700 No underslab inspection, stop work issued for no footing inspection.
Footing Inspection - Residential Failed - Stop Work 3/30/2021 03/30/2021
Misc
Corrective Action Required
03/30/2021
underslab plumbing was schedule prior to footing approval. no footing document was submitted or scheduled stop work issued.
Footing Inspection - Residential Passed 3/30/2021 03/30/2021
Misc
Resolved
03/30/2021
underslab plumbing was schedule prior to footing approval. no footing document was submitted or scheduled stop work issued.
Misc
Informational
03/30/2021
- 3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL - - UFER LOCATED IN CENTER OF NORTH (REAR GARAGE FOUNDATION WALL ) -
Underslab Plumbing Inspection - Residential Passed 4/1/2021 4/1/2021 04/01/2021
Misc
Resolved
04/01/2021
Please add your contract name and cell number so the inspector can contact the builder. not Summit and 246-6700 No underslab inspection, stop work issued for no footing inspection.
Piers/Caissons Inspection - Residential Passed 5/13/2021 (10:30) 5/13/2021 05/13/2021
Misc
Informational
05/13/2021
(2) 24 X 36 W/ (4) #4 VERT BARS
Erosion Control Inspection Residential Failed 5/13/2021 05/13/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/13/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GUTTER BUDDIES -
All Rough Inspection - Residential Failed 6/2/2021 6/2/2021 06/02/2021
Misc
Corrective Action Required
06/02/2021
NO PLANS / NO TRUSS LAYOUT
Electrical Service Inspection Passed 6/3/2021 06/03/2021
Gas Service Inspection - Residential Passed 6/3/2021 06/03/2021
All Rough Inspection - Residential Failed 6/3/2021 6/3/2021 06/03/2021
Misc
Corrective Action Required
06/02/2021
Provide anchor bolt within 12" of plate break garage at front door Tighten anchor bolts garage Seal upward penetrations rear wall garage Seal HVAC at mud room chase Seal DWV at mud room/ garage furr out Seal floor penetration gas line fireplace Seal fire blocking HVAC chases & fireplace great room Seal upward penetration dining room at stairs Seal dead space bed #5 closet Double over bored stud at fire place R602.6 bore 40% max 5/8 min to edge Provide 1 roof vent covered patio per plan Provide snow blocking flashing mud room Nail studs at wall corners at braced wall panels Seal upward penetrations at doorbell chime Provide (2) 2x4 under 2x10 foyer / bed #5 Provide 4 studs at GT bearing points Seal lid HVAC chase master tub Provide roof boots VTR throughout Seal upward penetration bed #4 Hanger missing nails master closet Missing hanger master closet Provide H2.5s covered patio Provide TJC37 hangers covered patio per plan Provide LUS24 hangers front porch per plan Seal cantilever basement near service panel Missing double joist hanger cantilever near service panel Provide (3) 2 x 10 joist above sub panel stairway per plan Provide 1" clearance B vent furnace Seal tub traps Provide anchor bolts SCH 40 columns Provide (3) 2x4 between SCH 40 columns per plan Provide flashing above horizontal trim windows
All Rough Inspection - Residential Passed 6/10/2021 6/10/2021 06/10/2021
Misc
Resolved
06/10/2021
Sewer Service Inspection - R Passed 6/17/2021 (8:45) 6/17/2021 06/17/2021
Water Service Inspection - R Passed 6/22/2021 06/22/2021
Driveway Inspection Not Ready 7/8/2021 7/8/2021 07/08/2021
Misc
Corrective Action Required
07/08/2021
Doesn’t have the required depth of aggregate. RP 7-8-21
Driveway Inspection Partial 7/9/2021 7/9/2021 07/09/2021
Misc
Corrective Action Required
07/08/2021
Doesn’t have the required depth of aggregate. RP 7-8-21
Misc
Informational
07/09/2021
Forms were placed and aggregate was present and compacted. RP 7-9-21
Driveway Inspection Passed 7/16/2021 7/16/2021 07/16/2021
Misc
Corrective Action Required
07/09/2021
Doesn’t have the required depth of aggregate. RP 7-8-21
Misc
Informational
07/09/2021
Forms were placed and aggregate was present and compacted. RP 7-9-21
Misc
Informational
07/16/2021
Finished driveway meets LS and ADA specs. RP 7-16-21
Sidewalk Inspection Partial 7/21/2021 7/21/2021 07/21/2021
Misc
Informational
07/21/2021
Forms were placed and aggregate was present and compacted for Shamrock. They still need to form and pour the Joshua side. They also need to replace a broken section of sidewalk by the ADA ramp. RP 7-21-21
Sidewalk Inspection Partial 7/26/2021 7/26/2021 07/26/2021
Misc
Corrective Action Required
07/26/2021
Forms were placed and aggregate was present and compacted. Still needs to remove and replace broken panel by the stop sign. RP 7-26-21
Sidewalk Inspection Failed 7/30/2021 7/30/2021 07/30/2021
Misc
Corrective Action Required
07/26/2021
Forms were placed and aggregate was present and compacted. Still needs to remove and replace broken panel by the stop sign. RP 7-26-21
Misc
Corrective Action Required
07/30/2021
Broken panel still hasn’t been replaced. RP 7-30-21
Erosion Control Inspection Residential Failed 8/11/2021 08/11/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/13/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GUTTER BUDDIES -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/11/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE UNTIL SOD COMPLETE - - REMOVE SEDIMENT BUILD UP AT GUTTER BUDDYS -
Occupancy Inspection - Codes Residential Failed 8/11/2021 8/11/2021 08/11/2021
Miscellaneous Correction
Corrective Action Required
08/10/2021
OBTAIN IRRIGATION PERMIT & SUBMIT BACKFLOW CERTIFICATION SIDEWALK INSPECTION FAILED PAY OUTSTANDING FEES REMOVE SEDIMENT BUILD UP AT GUTTER BUDDYS LOCATE MANHOLE COVER & BRING TO GRADE EAST SIDE PROVIDE FINAL GRADE PROVIDE SOD & SPLASH BLOCKS Seal exterior light fixtures exterior Provide handrail basement stairs Sewer tracer wire in a box at grade level Sump pump shall discharge 36" from foundation Seal top of meter can, ac disconnect Seal exterior penetrations at meter can ( low volt), gas meter,
Plot Plan Inspection Passed 9/14/2021 09/14/2021
Occupancy Inspection - Codes Residential Temporary C of O 9/14/2021 9/14/2021 09/14/2021
Miscellaneous Correction
Corrective Action Required
08/11/2021
OBTAIN IRRIGATION PERMIT & SUBMIT BACKFLOW CERTIFICATION SIDEWALK INSPECTION FAILED PAY OUTSTANDING FEES REMOVE SEDIMENT BUILD UP AT GUTTER BUDDYS LOCATE MANHOLE COVER & BRING TO GRADE EAST SIDE PROVIDE SPLASH BLOCK REAR EAST SIDE LOWER WATER METER LID TO GRADE
Occupancy Inspection - Codes Residential Not Ready 10/5/2021 10/5/2021 10/05/2021
Miscellaneous Correction
Corrective Action Required
09/14/2021
SIDEWALK INSPECTION FAILED PAY OUTSTANDING FEES REMOVE SEDIMENT BUILD UP AT GUTTER BUDDYS
Sidewalk Inspection Passed 10/7/2021 10/7/2021 10/07/2021
Misc
Resolved
10/07/2021
Forms were placed and aggregate was present and compacted. Still needs to remove and replace broken panel by the stop sign. RP 7-26-21
Misc
Resolved
10/07/2021
Broken panel still hasn’t been replaced. RP 7-30-21
Misc
Informational
10/07/2021
Sidewalk panel has been replaced 10-7-21 11:17 AN
Occupancy Inspection - Codes Residential Full C of O 10/12/2021 10/12/2021 10/12/2021
Miscellaneous Correction
Resolved
10/12/2021
REMOVE SEDIMENT BUILD UP AT GUTTER BUDDYS.
Documents & Images
Date Uploaded File Type Document Name
01/19/2021 Application Form W2 #47 - Permit App
01/19/2021 W2 #47 - TRUSS LAYOUT
01/19/2021 210210
01/19/2021 W2 #47 - Riverside - Modern Farm House - Sheets- signed
01/19/2021 LOT 47 FINAL
01/21/2021 Plans APPROVED HOUSE PLAN
01/21/2021 Specifications APPROVED TRUSS PACKAGE
01/21/2021 Drawing APPROVED TRUSS LAYOUT
01/21/2021 Letter Codes Residential Plan Review
01/26/2021 Plot Plan APPROVED PLOT PLAN
01/26/2021 Receipt Receipt for transaction:2021-000395
01/26/2021 Letter DS Building Permit
03/30/2021 Letter Stop Work Order
03/30/2021 Letter Stop Work Order
03/30/2021 Lot 47 Woodside Ridge Footing Inspection (002)
03/30/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/10/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/22/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/16/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
08/11/2021 Letter INSPECTION SUMMARY
08/11/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter Codes Temporary Certificate of Occupancy
10/05/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/11/2021 Receipt Receipt for transaction:2021-007883
10/12/2021 Letter Codes Final Certificate of Occupancy
10/13/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home