Summary
PRRES20210095
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS PACKAGE - UNFINISHED BASEMENT - COVERED DECK
01/07/2021
01/12/2021
01/06/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/11/2021 01/12/2021
Dylan Eppert
Residential Plan Review Approved 01/11/2021 01/11/2021
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,227.59 $1,227.59 Paid 01/12/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/12/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/12/2021
8331504-EFHB Middle Big Creek, Full $636.12 $636.12 Paid 01/12/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 01/12/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/12/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/12/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 02/22/2021
Misc
Corrective Action Required
02/22/2021
FOOTING POURED WITHOUT INSPECTION - SUBMIT ENGINEER REPORT
Underslab Plumbing Inspection - Residential Passed 3/24/2021 3/24/2021 03/24/2021
Footing Inspection - Residential Passed 3/24/2021 03/24/2021
Misc
Resolved
03/24/2021
FOOTING POURED WITHOUT INSPECTION - SUBMIT ENGINEER REPORT
All Rough Inspection - Residential Failed 5/25/2021 5/25/2021 05/25/2021
Misc
Corrective Action Required
05/25/2021
**HAVE TRUSS PLANS ON SITE IF COVERED PORCH/DECK TRUSSES TO BE INSPECTED AT SAME TIME AS GARAGE PORTAL** -PANEL SPLICE SHALL OCCUR OVER AND BE NAILED TO COMMON BLOCKING WITHIN THE MIDDLE 24" OF THE PORTAL LEG HEIGHT. ONE ROW OF 3" OC NAILING REQ EACH PANEL EDGE -FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" O.C. -HEADER TO JACK STUD STRAP REQ, SEE R602.10.6.4 -INSTALL NUTS AND 2"X2"X3/16" PLATE WASHERS AT ANCHOR BOLTS -ANCHOR BOLTS SHOULD BE IN MIDDLE THIRD OF PLATE
Gas Service Inspection - Residential Passed 6/10/2021 6/10/2021 06/10/2021
All Rough Inspection - Residential Failed 6/29/2021 6/29/2021 06/29/2021
Misc
Corrective Action Required
05/25/2021
***6/29/21*** -RESTORE GRAVEL FILTER AT DRIVE AND SILT FENCE AT PERIMETER AND CLEAN DEBRIS FROM STREETS BEFORE ANY FURTHER INSPECTIONS- **HAVE TRUSS PLANS ON SITE IF COVERED PORCH/DECK TRUSSES TO BE INSPECTED AT SAME TIME AS GARAGE PORTAL** -PANEL SPLICE SHALL OCCUR OVER AND BE NAILED TO COMMON BLOCKING WITHIN THE MIDDLE 24" OF THE PORTAL LEG HEIGHT. ONE ROW OF 3" OC NAILING REQ EACH PANEL EDGE -FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" O.C. -HEADER TO JACK STUD STRAP REQ, SEE R602.10.6.4 -INSTALL NUTS AND 2"X2"X3/16" PLATE WASHERS AT ANCHOR BOLTS -ANCHOR BOLTS SHOULD BE IN MIDDLE THIRD OF PLATE -COMPLETE NAILING PATTERN AT ALL STUDS AT PFH
All Rough Inspection - Residential Failed 7/2/2021 7/2/2021 07/02/2021
Misc
Corrective Action Required
06/29/2021
Restore gravel filter and maintain erosions control silt fence at front of lot **CORRECTIONS FROM 5/29 GARAGE PFH INSPECTION REMAIN** -PANEL SPLICE SHALL OCCUR OVER AND BE NAILED TO COMMON BLOCKING WITHIN THE MIDDLE 24" OF THE PORTAL LEG HEIGHT. ONE ROW OF 3" OC NAILING REQ EACH PANEL EDGE -FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" O.C. -NAIL COMPLETE HEADER TO JACK STUD STRAPS -INSTALL NUTS AND 2"X2"X3/16" PLATE WASHERS AT ANCHOR BOLTS -ANCHOR BOLTS SHOULD BE IN MIDDLE THIRD OF PLATE -COMPLETE NAILING PATTERN AT ALL STUDS AT PFH -Anchor bolts required with 12” of plate break - garage and basement -Anchor steel column to floor in garage -Exterior sheathing at North and south garage walls -Fireblock vertical to horizontal at DWV fur out garage -Seal all penetrations through air returns -Insulate first, then solid block between joists at cantilevers -Protection plates at DWV bottom plate kitchen/pantry -Fireblock chases at great room windows -Secure gas flex line at fireplace -Nail all joist hangers 1st floor -Support cut LVL at kitchenwall -(3) Overbored floor joists for DWV, above kitchen 1st floor, replace or submit engineer letter -Penetrations bored through floor joists must be min 2” apart, (8) joists bored for pex water lines less than 2” apart, above kitchen and great room 1st floor, replace or submit engineer letter -sgl joist bored less than 2” from top of joist for NM, 1st floor above great room, repl or submit engineer letter -Joist hangers required at joist, header, see 1st floor above great room -12” o.c. Nailing at all abutting and intersecting wall corners (braced walls) -seal all top and bottom plate penetrations -Add joist hangers at front covered porch sgl joists -Unable to inspect truss hangers at covered porch due to cover, remove lid -All truss hangers per plans -W16x31 steel beam to bear on 3” SCH 40 steel column per plans at N wall -(4) 2x4 stud pack at garage/kitchen wall per plans -(2) 2x4 at garage/foyer closet wall per plans -Nail H2.5 strap, 2nd floor bed#3 and front bed 2nd floor -Fireblock all tub and shower traps -Protection plate at DWV bottom plate laundry -Strap 2x6 to 2x4 top plate, 2nd floor stairs -(4) 2x4 stud packs at all girder truss bearing ends per plans -All truss bracing per plans -Tighten all anchor bolts at basement -(3) 2x10 joists at stair header basement per plans -(3) 1 3/4” x 9 1/4” lvl at basement window header per plans -solid block between joists every 48” o.c. Per plans for kitchen island -Shim or replace Jack studs at basement egress window, cut short of header -Nail exterior sheathing per plans -Nail hold down strap, N side of front porch **DECK INCOMPLETE AT ROUGH INSPECTION**
All Rough Inspection - Residential Failed 7/12/2021 7/12/2021 07/12/2021
Misc
Corrective Action Required
07/02/2021
**7/12/21 - INSPECTION DENIED, CLEAN ALL MUD AND GRAVEL FROM STREET, MAINTAIN EROSION CONTROL, GRAVEL FILTER W/ 4" LIFT REQUIRED** **CORRECTIONS FROM 5/29 GARAGE PFH INSPECTION REMAIN** -PANEL SPLICE SHALL OCCUR OVER AND BE NAILED TO COMMON BLOCKING WITHIN THE MIDDLE 24" OF THE PORTAL LEG HEIGHT. ONE ROW OF 3" OC NAILING REQ EACH PANEL EDGE -FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" O.C. -NAIL COMPLETE HEADER TO JACK STUD STRAPS -INSTALL NUTS AND 2"X2"X3/16" PLATE WASHERS AT ANCHOR BOLTS -ANCHOR BOLTS SHOULD BE IN MIDDLE THIRD OF PLATE -COMPLETE NAILING PATTERN AT ALL STUDS AT PFH -Anchor bolts required with 12” of plate break - garage and basement -Anchor steel column to floor in garage -Exterior sheathing at North and south garage walls -Fireblock vertical to horizontal at DWV fur out garage -Seal all penetrations through air returns -Insulate first, then solid block between joists at cantilevers -Protection plates at DWV bottom plate kitchen/pantry -Fireblock chases at great room windows -Secure gas flex line at fireplace -Nail all joist hangers 1st floor -Support cut LVL at kitchenwall -(3) Overbored floor joists for DWV, above kitchen 1st floor, replace or submit engineer letter -Penetrations bored through floor joists must be min 2” apart, (8) joists bored for pex water lines less than 2” apart, above kitchen and great room 1st floor, replace or submit engineer letter -sgl joist bored less than 2” from top of joist for NM, 1st floor above great room, repl or submit engineer letter -Joist hangers required at joist, header, see 1st floor above great room -12” o.c. Nailing at all abutting and intersecting wall corners (braced walls) -seal all top and bottom plate penetrations -Add joist hangers at front covered porch sgl joists -Unable to inspect truss hangers at covered porch due to cover, remove lid -All truss hangers per plans -W16x31 steel beam to bear on 3” SCH 40 steel column per plans at N wall -(4) 2x4 stud pack at garage/kitchen wall per plans -(2) 2x4 at garage/foyer closet wall per plans -Nail H2.5 strap, 2nd floor bed#3 and front bed 2nd floor -Fireblock all tub and shower traps -Protection plate at DWV bottom plate laundry -Strap 2x6 to 2x4 top plate, 2nd floor stairs -(4) 2x4 stud packs at all girder truss bearing ends per plans -All truss bracing per plans -Tighten all anchor bolts at basement -(3) 2x10 joists at stair header basement per plans -(3) 1 3/4” x 9 1/4” lvl at basement window header per plans -solid block between joists every 48” o.c. Per plans for kitchen island -Shim or replace Jack studs at basement egress window, cut short of header -Nail exterior sheathing per plans -Nail hold down strap, N side of front porch **DECK INCOMPLETE AT ROUGH INSPECTION**
Erosion Control Inspection Residential Failed 7/12/2021 7/12/2021 07/12/2021
Misc
Corrective Action Required
07/12/2021
INSPECTION DENIED, CLEAN ALL MUD AND GRAVEL FROM STREET, MAINTAIN EROSION CONTROL, GRAVEL FILTER W/ 4" LIFT REQUIRED
Sewer Service Inspection - R Passed 7/23/2021 (9:15) 7/23/2021 07/23/2021
Water Service Inspection - R Partial 7/23/2021 7/23/2021 07/23/2021
Misc
Informational
07/23/2021
-PARTIAL INSPECTION ON PEX TO HOUSE ENTRANCE
Water Service Inspection - R Passed 7/26/2021 (9:00) 7/26/2021 07/26/2021
Misc
Resolved
07/26/2021
All Rough Inspection - Residential Failed 7/26/2021 7/26/2021 07/26/2021
Misc
Corrective Action Required
07/12/2021
-NAIL COMPLETE HEADER TO JACK STUD STRAPS -Anchor bolts required with 12” of plate break - garage and basement -Fireblock at DWV fur out garage -Seal all penetrations through air returns -Insulate first, then solid block between joists at cantilevers -Fireblock chases at great room windows, seal gaps at fireblock material -(3) Overbored floor joists for DWV, above kitchen 1st floor, submit engineer letter on field fix -Penetrations bored through floor joists must be min 2” apart, (8) joists bored for pex water lines less than 2” apart, above kitchen and great room 1st floor, submit engineer letter on field fix -sgl joist bored less than 2” from top of joist for NM, 1st floor above great room, repl or submit engineer letter -seal all top and bottom plate penetrations -great room -W16x31 steel beam to bear on 3” SCH 40 steel column per plans at N wall (7/26/21 - nail exterior sheathing per plans that was nailed to stud pack at beam) -Fireblock all tub and shower traps
All Rough Inspection - Residential Failed 7/29/2021 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/26/2021
-NAIL COMPLETE HEADER TO JACK STUD STRAPS -Anchor bolts required with 12” of plate break - garage and basement -solid block between joists at cantilevers -Fireblock chases at great room windows, vertical to horizontal -(3) Overbored floor joists for DWV, above kitchen 1st floor, submit engineer letter on field fix -Penetrations bored through floor joists must be min 2” apart, (8) joists bored for pex water lines less than 2” apart, above kitchen and great room 1st floor, field repair per engineer letter -sgl joist bored less than 2” from top of joist for NM, 1st floor above great room - repair per engineer letter -W16x31 steel beam to bear on 3” SCH 40 steel column per plans at N wall (7/26/21 - nail exterior sheathing per plans that was nailed to stud pack at beam)
All Rough Inspection - Residential Passed 8/3/2021 8/3/2021 08/03/2021
Misc
Resolved
08/03/2021
Electrical Service Inspection Passed 9/14/2021 9/14/2021 09/14/2021
Driveway Inspection Passed 10/21/2021 10/21/2021
Misc
Informational
10/21/2021
On 10/.21/2021 I performed a driveway inspection and pass the subgrade to pour concrete. DJ
Sidewalk Inspection Passed 10/21/2021 10/21/2021
Misc
Informational
10/21/2021
I performed a sidewalk inspection and pass the subgrade to pour concrete. DJ
Occupancy Inspection - Codes Residential Failed 10/29/2021 10/29/2021 10/29/2021
Misc
Corrective Action Required
10/29/2021
-Complete final grade and sod -splash blocks and sump pump discharge 36” from foundation -seal top of lights at house front, right and left of garage -guard rail as required at front stoop -to much trash in garage to inspect inside garage -adjust self closing door at garage -spark ring required above fire place -broken window at north wall stairs -hole in wall at south wall above outlet exposing back of adjacent wall junction box -sheer off set screw for anti-siphon device -deck guard rail spacing must not be more that 4” -seal top of A/c disconnect & meter can -check meter at time of final grade
Occupancy Inspection - Codes Residential Temporary C of O 11/24/2021 11/24/2021 11/24/2021
Misc
Corrective Action Required
10/29/2021
TCO until 12/22/21 -Complete final grade and sod -splash blocks and sump pump discharge 36” from foundation -guard rail as required at front stoop/final grade -check meter at time of final grade Mitchell Schwarz 11/24/2021 9:57 AM
Plot Plan Inspection Passed 12/2/2021 12/2/2021 12/02/2021
Erosion Control Inspection Residential Passed 12/02/2021
Misc
Resolved
12/02/2021
INSPECTION DENIED, CLEAN ALL MUD AND GRAVEL FROM STREET, MAINTAIN EROSION CONTROL, GRAVEL FILTER W/ 4" LIFT REQUIRED
Occupancy Inspection - Codes Residential Failed 12/2/2021 12/2/2021 12/02/2021
Misc
Corrective Action Required
11/24/2021
TCO until 12/22/21 -Obtain lawn irrigation system permit -6" clearance required siding to sod - see east side rear of house and north/south corners at rear
Occupancy Inspection - Codes Residential Failed 12/8/2021 12/8/2021 12/08/2021
Misc
Corrective Action Required
12/02/2021
TCO until 12/22/21 -6" clearance required siding to sod - see east side rear of house and north/south corners at rear
Occupancy Inspection - Codes Residential Failed 12/17/2021 12/17/2021 12/17/2021
Misc
Corrective Action Required
12/08/2021
TCO until 12/22/21 -6" clearance required siding to sod - see east side rear of house and north/south corners at rear
Occupancy Inspection - Codes Residential Failed 12/30/2021 12/30/2021 12/30/2021
Misc
Corrective Action Required
12/17/2021
TCO until 12/22/21 -6" clearance required siding to sod - see east side rear of house and north/south corners at rear
Occupancy Inspection - Codes Residential Full C of O 1/6/2022 1/6/2022 01/06/2022
Misc
Resolved
01/06/2022
TCO until 12/22/21 -6" clearance required siding to sod - see east side rear of house and north/south corners at rear
Documents & Images
Date Uploaded File Type Document Name
01/07/2021 Application Form MN #99 - PERMIT APPLICATION
01/07/2021 MN #99 - TRUSS LAYOUT
01/07/2021 MN #99 - Palmer II - Old World - Sheets- signed
01/07/2021 MN 99
01/07/2021 LOT 99 FINAL 1-7-21
01/07/2021 APPROVED TRUSS LAYOUT
01/07/2021 APPROVED TRUSS PACKAGE
01/12/2021 Plot Plan APPROVED PLOT PLAN
01/12/2021 Approved Plans APPROVED HOUSE PLAN
01/12/2021 Receipt Receipt for transaction:2021-000155
01/12/2021 Letter DS Building Permit
02/22/2021 Letter INSPECTION SUMMARY
03/23/2021 Lot 99 Manor at Stoney Creek wall inspection
03/23/2021 Lot 99 Manor at Stoney Creek Footing Inspection
03/24/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
05/25/2021 Letter INSPECTION SUMMARY
06/10/2021 Letter INSPECTION SUMMARY
06/29/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
07/28/2021 MN99framingletter
07/29/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/29/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter Codes Temporary Certificate of Occupancy
12/02/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
12/30/2021 Letter INSPECTION SUMMARY
01/06/2022 Letter Field Certificate of Occupancy
01/06/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home