Permit Application Status

PRRES20210022


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210022
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
01/04/2021
01/19/2021
07/06/2021
03/23/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 01/06/2021 01/19/2021
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
01/04/2021

Please label all exterior materials
Plot Plan Review Approved 01/14/2021 01/12/2021
Dylan Eppert
Deck location
Corrective Action Required
01/12/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
01/12/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Basement egress
Corrective Action Required
01/12/2021

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
City infrustructure
Corrective Action Required
01/12/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. MISING STORM MANHOLE IN REAR YARD AS WELL AS STORM INLET IN FRONT YARD, MISSING SANITARY LINE, STUB LOCATIONS AND SEWER MAN HOLE.
Residential Plan Review Approved 01/14/2021 01/12/2021
Dylan Eppert
Plot Plan Review Rejected 01/07/2021 01/07/2021
Dylan Eppert
Deck location
Corrective Action Required
01/07/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
01/07/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Basement egress
Corrective Action Required
01/07/2021

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
City infrustructure
Corrective Action Required
01/07/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. MISING STORM MANHOLE IN REAR YARD AS WELL AS STORM INLET IN FRONT YARD, MISSING SANITARY LINE, STUB LOCATIONS AND SEWER MAN HOLE.
Residential Plan Review Approved 01/06/2021 01/06/2021
Dylan Eppert
Planning Review (RES) Rejected 01/06/2021 01/04/2021
Victoria Nelson
Miscellaneous Correction
Corrective Action Required
01/04/2021

Please label all exterior materials
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,252.92 $1,252.92 Paid 01/19/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 01/19/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/19/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/19/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/19/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/19/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/1/2021 (8:30) 3/1/2021 03/01/2021
Misc
Informational
03/01/2021
- UFER MIDDLE OF SOUTH FOUNDATION WALL -
Underslab Plumbing Inspection - Residential Failed 4/13/2021 4/13/2021 04/13/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
04/13/2021
- COMPLETE INTERIOR UNDERSLAB DRAIN TILE - CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Underslab Plumbing Inspection - Residential Passed 4/15/2021 4/15/2021 04/15/2021
R506.2.5 Interior Underslab Drains
Resolved
04/15/2021
All Rough Inspection - Residential Partial 6/23/2021 6/23/2021 06/23/2021
Misc
Informational
06/23/2021
: PORTAL FRAMING ONLY : 3" O.C. NAILING PATTERN & HOLDDOWN NAILING APPROVED OK TO COVER
Piers/Caissons Inspection - Residential Failed 6/29/2021 (8:00) 6/29/2021 06/29/2021
Misc
Corrective Action Required
06/29/2021
Pier holes are completely full of water
Piers/Caissons Inspection - Residential Passed 7/7/2021 7/7/2021 07/07/2021
Misc
Informational
07/07/2021
(2) 24 X 36
Sewer Service Inspection - R Passed 7/16/2021 (11:00) 7/16/2021 07/16/2021
Water Service Inspection - R Passed 7/26/2021 07/26/2021
Electrical Service Inspection Passed 8/17/2021 8/17/2021 08/17/2021
Gas Service Inspection - Residential Passed 8/17/2021 8/17/2021 08/17/2021
All Rough Inspection - Residential Failed 8/17/2021 8/17/2021 08/17/2021
Misc
Informational
06/23/2021
: PORTAL FRAMING ONLY : 3" O.C. NAILING PATTERN & HOLDDOWN NAILING APPROVED OK TO COVER
Miscellaneous Correction
Corrective Action Required
08/17/2021
Fire block dead space office Provide LIB at master bed door per plan Provide Nail hangers at box beam master Provide rafter ties north wall master bed Provide mid point support Vertical DWV 2" or smaller master shower Nail exterior wall sheathing master closet Nail stud shoes master vanity Provide (3) 2 x 10 flush per plan deck Provide solid security blocking deck door latch side Provide joist hanger near LVLs dining room Seal upward penetration pantry Tighten anchor bolts garage Provide attic access Provide collar ties @ 48" OC where required Tighten anchor bolts basement Provide anchor bolts within 12" of plate break near service panel Provide stringer connectors per plan Provide anchor bolts SCH 40 column near furnace Bed #2 basement plans call for (3) LVLs or W8x10 beam above door framed dbl 2 x 10 Provide solid blocking @ 48" OC under kitchen island per plan
All Rough Inspection - Residential Passed 8/30/2021 8/30/2021 08/30/2021
Misc
Informational
08/17/2021
: PORTAL FRAMING ONLY : 3" O.C. NAILING PATTERN & HOLDDOWN NAILING APPROVED OK TO COVER
Miscellaneous Correction
Resolved
08/30/2021
Driveway Inspection Partial 9/24/2021 9/24/2021 09/23/2021
Misc
Informational
09/23/2021
Forms are in places and aggregate is present and compacted. Had worker adjust the form to reach the 1.5% slope. Ready to concrete
Driveway Inspection Partial 9/24/2021 9/24/2021 09/24/2021
Misc
Informational
09/23/2021
Forms are in places and aggregate is present and compacted. . Ready to concrete
Driveway Inspection Passed 10/1/2021 10/1/2021 10/01/2021
Misc
Informational
09/24/2021
Forms are in places and aggregate is present and compacted. . Ready to concrete
Misc
Informational
10/01/2021
Driveway looks good and has expansion joints at the curb and right of way. No sidewalk
Occupancy Inspection - Codes Residential Temporary C of O 2/4/2022 2/4/2022 02/04/2022
Misc
Corrective Action Required
02/04/2022
TCO UNTIL 4/4/22 -complete final grade and sod -check water meter and siding from ground at time of sod -splash blocks and sump pump discharge to extend 36” from foundation -seal top of meter can, A/c disconnect & all other exterior penetrations
Plot Plan Inspection Passed 5/10/2022 05/10/2022
Occupancy Inspection - Codes Residential Temporary C of O 5/10/2022 5/10/2022 05/10/2022
Misc
Corrective Action Required
02/04/2022
TCO UNTIL 5/27/22 -check siding from ground at time of sod PROVIDE 6 INCHES CLEARANCE FROM WOOD SIDING TO GRADE ( 1018 IRC R317.1 (5) Obtain Lawn irritation permit & submit back flow certification LAND SEWER TRACER WIIRE IN A BOX AT GRADE LEVEL
Occupancy Inspection - Codes Residential Full C of O 3/23/2023 3/23/2023 03/23/2023
Misc
Resolved
03/23/2023
TCO UNTIL 5/27/22 -check siding from ground at time of sod PROVIDE 6 INCHES CLEARANCE FROM WOOD SIDING TO GRADE ( 2018 IRC R317.1 (5) Obtain Lawn irritation permit & submit back flow certification LAND SEWER TRACER WIIRE IN A BOX AT GRADE LEVEL
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home