Permit Application Status

PRRES20204861


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204861
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK - ROOF TRUSS PACKAGE
12/21/2020
01/11/2021
06/21/2021
11/24/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/12/2021 01/08/2021
Dylan Eppert
Lot elevations
Corrective Action Required
01/08/2021

Existing and finish elevations at all property corners must be provided on the plot plan. PEASE CLARIFY THE REAR EAST SIDE PROPERTY CORNER ELEVATION. MDP SHOWS 969.89 AND THE PLOT PLAN SHOWS 973.27 ARE YOU HAVING TO BRING FILL IN? IT WAS NOT MARKED ON THE APPLICATION.
Residential Plan Review Approved 01/12/2021 01/08/2021
Dylan Eppert
Plot Plan Review Rejected 12/23/2020 12/23/2020
Dylan Eppert
Lot elevations
Corrective Action Required
12/23/2020

Existing and finish elevations at all property corners must be provided on the plot plan. PEASE CLARIFY THE REAR EAST SIDE PROPERTY CORNER ELEVATION. MDP SHOWS 969.89 AND THE PLOT PLAN SHOWS 973.27 ARE YOU HAVING TO BRING FILL IN? IT WAS NOT MARKED ON THE APPLICATION.
Residential Plan Review Approved 12/23/2020 12/23/2020
Dylan Eppert
Planning Review (RES) Approved 12/23/2020 12/21/2020
Shannon McGuire
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,348.05 $1,348.05 Paid 01/11/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 01/11/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/11/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/11/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/11/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/11/2021
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/26/2021 (2:00) 1/26/2021 01/26/2021
Misc
Informational
01/26/2021
- POST ADDRESS - - UFER FOUNDATION WALL REAR OF GARAGE -
Sewer Service Inspection - R Passed 3/5/2021 (11:30) 3/5/2021 03/05/2021
Water Service Inspection - R Passed 3/8/2021 (11:30) 3/8/2021 03/08/2021
Underslab Plumbing Inspection - Residential Failed 3/23/2021 3/23/2021 03/23/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
03/23/2021
- BACKFILL NOT COMPLETE APPEARS NEED TO COMPLETE DRAIN TILE CONNECTION TO SUMP - CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Underslab Plumbing Inspection - Residential Passed 3/29/2021 3/29/2021 03/29/2021
R506.2.5 Interior Underslab Drains
Resolved
03/29/2021
Piers/Caissons Inspection - Residential Passed 4/26/2021 (9:15) 4/26/2021 04/26/2021
Electrical Service Inspection Passed 6/18/2021 6/18/2021 06/18/2021
Gas Service Inspection - Residential Passed 6/18/2021 6/18/2021 06/18/2021
All Rough Inspection - Residential Failed 6/18/2021 6/18/2021 06/18/2021
Miscellaneous Correction
Corrective Action Required
06/18/2021
-Nail sheathing to all studs at PFH per code -Seal penetrations in moisture barrier -Provide 5/8" bolt and 2x2x 3/16 square washer through all bottom plates at PFH -Nail top plate to header with 16d sinkers (2) rows 3" oc at PFH -Exterior sheathing braced walls are not nailed per code or per plan and have been covered with siding-none of these walls can be verified as being acceptable braced walls (see garage wall bottom plates for obvious examples)-An engineer will need to provide a correction or an alternative method to achieve the necessary braced wall design -Tighten anchor bolts throughout -Anchor bolts to be in middle 3rd of plate in garage -Address joist bored closer than 2" to top of joist at dwv in garage -Missing H2.5s at truss against house at covered patio -Bocca plate at refrigerator -Seal gaps in fireblocking at west dead space in great room -Replace stud bored closer than 5/8" to edge and provide stud shoe or double as necessary -Seal gaps at top plates in fire place bump out -Address joists overbored for DWV in great room -Midpoint strap on 2" dwv at entry and laundry -Attic access requires 30" clearnce above -Provide appropriate solid shims under beams at beam pockets in basement
All Rough Inspection - Residential Not Ready 7/7/2021 7/7/2021 07/07/2021
Miscellaneous Correction
Corrective Action Required
06/18/2021
-Seal penetrations in moisture barrier ( Tyvek tape ) - tighten 5/8" bolt @ PFH PORTAL -Nail top plate to header with 16d sinkers (2) rows 3" oc at PFH -Exterior sheathing braced walls are not nailed per code or per plan and have been covered with siding-none of these walls can be verified as being acceptable braced walls (see garage wall bottom plates for obvious examples)-An engineer will need to provide a correction or an alternative method to achieve the necessary braced wall design -Tighten anchor bolt north garage wall -Address joist bored closer than 2" to top of joist at dwv in garage -Missing H2.5s at truss against house at covered patio -Replace stud bored closer than 5/8" to edge and provide stud shoe or double as necessary ( laundry room strap per engineer letter ) -Seal gaps at top plates in fire place bump out -Midpoint strap on 2" dwv at entry and laundry
All Rough Inspection - Residential Passed 7/12/2021 7/12/2021 07/12/2021
Miscellaneous Correction
Resolved
07/12/2021
Sidewalk Inspection Partial 8/16/2021 8/16/2021 08/16/2021
Misc
Informational
08/16/2021
Forms were placed and aggregate was present and compacted. RP 8-16-21
Driveway Inspection Partial 8/16/2021 8/16/2021 08/16/2021
Misc
Informational
08/16/2021
Forms were placed and aggregate was present and compacted. RP 8-16-21
Driveway Inspection Failed 8/20/2021 8/20/2021 08/20/2021
Misc
Informational
08/16/2021
Forms were placed and aggregate was present and compacted. RP 8-16-21
Misc
Corrective Action Required
08/20/2021
Need to patch or replace curbing where it meets with the approach. RP 8-20-21
Sidewalk Inspection Passed 8/20/2021 8/20/2021 08/20/2021
Misc
Informational
08/16/2021
Forms were placed and aggregate was present and compacted. RP 8-16-21
Misc
Informational
08/20/2021
Finished sidewalk meets LS and ADA specs. RP 8-20-21
Occupancy Inspection - Codes Residential Failed 11/4/2021 11/4/2021 11/04/2021
Misc
Corrective Action Required
11/04/2021
-seal top of front lights at siding,top of A/c disconnect & meter can -sod & final grade - provide splash blocks and sump pump extension 36” from foundation -guard rail required at front stoop where more than 30” from grade -Self closing door at garage -provide bonding for Csst gas line per code
Occupancy Inspection - Codes Residential Failed 11/12/2021 11/12/2021 11/11/2021
Misc
Corrective Action Required
11/04/2021
-guard rail required at front stoop where more than 30” from grade -Self closing door at garage
Occupancy Inspection - Codes Residential Full C of O 11/24/2021 11/24/2021 11/24/2021
Misc
Resolved
11/24/2021
Documents & Images
Date Uploaded File Type Document Name
12/21/2020 Application Form W0 #82 - Permit App
12/21/2020 W0 #82 - TRUSS LAYOUT
12/21/2020 W0 #82 - Canterbury - Modern Farmhouse - Sheets- signed
12/21/2020 LOT 82 FINAL
12/21/2020 W0 82
12/23/2020 Specifications APPROVED TRUSS PACKAGE
12/23/2020 Drawing APPROVED TRUSS LAYOUT
12/23/2020 Plans APPROVED HOUSE PLAN
12/23/2020 Letter Codes Residential Plan Review
01/08/2021 Plot Plan APPROVED PLOT PLAN
01/11/2021 Receipt Receipt for transaction:2021-000135
01/11/2021 Letter DS Building Permit
01/26/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/08/2021 Letter INSPECTION SUMMARY
03/23/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
04/26/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
07/01/2021 82 woodside ridge holes in floor joist and wall stud letter
07/07/2021 Letter INSPECTION SUMMARY
07/07/2021 82 WOODSIDE RIDGE BRACED WALL PANEL NAILING PATTERN LETTER (002)
07/09/2021 82 woodside ridge hole in floor joist letter #2
07/12/2021 Letter INSPECTION SUMMARY
08/16/2021 Letter INSPECTION SUMMARY
08/16/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter Codes Final Certificate of Occupancy
11/24/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.