Permit Application Status

PRRES20204555


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204555
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED DECK
12/02/2020
12/08/2020
08/05/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
PERMITTING@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/04/2020 12/02/2020
Brandon Kalwei
Residential Plan Review Approved 12/04/2020 12/02/2020
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,158.24 $1,158.24 Paid 12/08/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 12/08/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/08/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/08/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/08/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/08/2020
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 12/08/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/29/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/30/2020 (3:15) 12/30/2020 12/30/2020
Underslab Plumbing Inspection - Residential Passed 1/21/2021 1/21/2021 01/21/2021
All Rough Inspection - Residential Failed 3/24/2021 3/24/2021 03/24/2021
Misc
Informational
03/24/2021
-OK TO COVER PORCH AND COVERED DECK
Miscellaneous Correction
Corrective Action Required
03/24/2021
-PORTAL FRAMING REQUIRES 3" NAILING PATTERN ON ALL STUDS AND 16D NAILS FROM TOP PLATE TO HEADER 3" OC
All Rough Inspection - Residential Partial 3/25/2021 3/25/2021 03/25/2021
Misc
Informational
03/24/2021
-3/25/21 INSPECTED GARAGE PORTAL
Miscellaneous Correction
Resolved
03/25/2021
Piers/Caissons Inspection - Residential Passed 4/2/2021 (11:30) 4/2/2021 04/02/2021
All Rough Inspection - Residential Not Ready 4/7/2021 4/7/2021 04/07/2021
Misc
Informational
03/25/2021
-3/25/21 INSPECTED GARAGE PORTAL -4/7/21 - NO INSPECTION PERFORMED, NO CITY APPROVED PLANS ON SITE
Gas Service Inspection - Residential Passed 4/9/2021 4/9/2021 04/09/2021
Electrical Service Inspection Passed 4/9/2021 4/9/2021 04/09/2021
All Rough Inspection - Residential Failed 4/9/2021 4/9/2021 04/09/2021
Misc
Informational
04/07/2021
-No city approved truss plans on site, unable to inspect trusses -Remove front porch and covered deck lids to allow for inspection of trusses and hold downs -H2.5 clips at all hip trusses -2x4 laid flat at furred down in garage 3’ or more needs to be connected to floor joist to support the ceiling load -Fireblock DWV chase in garage -Pressure treated wood required at chase framing in contact with concrete wall in garage -3” SCH 40 steel column at W14x22 beam in garage per plans -(2) 2x10 rim for covered porch not bearing across 2x4 studs at garage -(3) 2x4 studs for bearing of (3) 2x10 joists at garage between sgl and dbl garage per plans -attic access at garage above dbl door per plans -(2) 2x10 header at garage to mud door Seal all top plate penetrations - see living room chase, -fur down at HVAC in garage ceiling -support DWV every 48” oc, traps not considered support -Fireblock vertical to horizontal at living room chases at windows -secure gas flex line at fireplace -triple joist hanger at joist to lvl connection above foyer 1st floor -correct 2x10 joist hanger at 2nd stair landing above foyer -header at floor joist cut for HVAC at box out in kitchen near refer, joist supported by non load bearing wall -LIB bracing, all locations per plans -strap top plate cut at pantry -address cut king stud at kitchen window for DWV -(3) 2x4 stud pack at lvl bearing ends above breakfast per plans -security blocking at exterior doors -properly support all stair landings -top and bottom plate cut out for b vent at HVAC chase, 2nd floor laundry (4) 2x4 stud pack at all girder truss bearing ends per plans -snow blocking at 2nd floor -12” oc nailing at all abutting and intersecting wall corners (braced walls) -Anchor bolts required within 12” of plate break in garage -Joist hanger required at joist to header, East side basement, over 4' -solid blocking between joists every 48” oc for kitchen island per plans -dbl 2x6 studs at bearing end of dbl joists in basement -submit engineer report on w8x15 steel beam not bearing full on concrete pocket and supported by 2x6 -receptacle required within 25’ of exterior HVAC equipment on same level -Nail exterior sheathing per plans, 6” edge, 12” field **Deck not complete at time of rough in inspection**
All Rough Inspection - Residential Failed 4/20/2021 4/20/2021 04/20/2021
Misc
Informational
04/09/2021
-Fireblock DWV chase in garage -3” SCH 40 steel column at W14x22 beam in garage per plans -attic access at garage above dbl door per plans -Seal all top plate penetrations - see living room chase, crushed HVAC duct in chase from fireblock correction -support DWV every 48” oc, traps not considered support -secure gas flex line at fireplace -LIB bracing, all locations and layout per plans -strap top plate cut at pantry -address cut king stud at kitchen window for DWV -correct DWV that has been cut and land NM to boxes, secure boxes, removed for correction of king stud, stud shoes -All truss hangers per plans-see garage -Truss lateral bracing per plans-2nd floor -properly support all stair landings -top and bottom plate cut out for b vent at HVAC chase, 2nd floor laundry (4) 2x4 stud pack at all girder truss bearing ends per plans -12” oc nailing at all abutting and intersecting wall corners (braced walls) -submit engineer report on w8x15 steel beam not bearing full on concrete pocket and supported by 2x6
All Rough Inspection - Residential Failed 4/27/2021 4/27/2021 04/27/2021
Misc
Corrective Action Required
04/27/2021
-submit engineer report on w8x15 steel beam not bearing full on concrete pocket and supported by 2x6
All Rough Inspection - Residential Failed 4/29/2021 4/29/2021 04/29/2021
Misc
Corrective Action Required
04/27/2021
-w8x15 steel beam not bearing full on concrete pocket and supported by 2x6 Engineer report received, will need to inspect pier pad prior to pour **OK TO INSULATE**
All Rough Inspection - Residential Passed 5/6/2021 5/6/2021 05/06/2021
Misc
Resolved
05/06/2021
Sewer Service Inspection - R Passed 5/14/2021 (9:30) 5/14/2021 05/14/2021
Water Service Inspection - R Passed 5/17/2021 (9:45) 5/17/2021 05/17/2021
Driveway Inspection Passed 5/21/2021 5/21/2021 05/24/2021
Sidewalk Inspection Passed 5/21/2021 5/21/2021 05/24/2021
Erosion Control Inspection Residential Passed 07/28/2021
Occupancy Inspection - Codes Residential Failed 7/28/2021 7/28/2021 07/28/2021
Misc
Corrective Action Required
07/28/2021
-Pay all fees due before final occupancy -Clean mud from street in front of property -Misisng cover plate at front entry -Install missing fixture above stairs -Secure handrail at stairs -Adjust garage entry door to close and latch -Label all dedicated non GFCI outlets in garage and basement
Plot Plan Inspection Passed 8/5/2021 8/5/2021 08/05/2021
Occupancy Inspection - Codes Residential Full C of O 8/5/2021 8/5/2021 08/05/2021
Misc
Resolved
08/05/2021
Documents & Images
Date Uploaded File Type Document Name
12/02/2020 Application Form APPLICATION
12/02/2020 Approved Plans APPROVED DRAWINGS
12/02/2020 Approved Plans APPROVED TRUSS DRAWINGS
12/02/2020 Approved Plans APPROVED TRUSS DRAWINGS
12/02/2020 Plot Plan APPROVED PLOT PLAN
12/08/2020 Receipt Receipt for transaction:2020-007911
12/08/2020 Letter DS Building Permit
12/30/2020 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/25/2021 Letter INSPECTION SUMMARY
04/02/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/09/2021 Letter INSPECTION SUMMARY
04/09/2021 Letter INSPECTION SUMMARY
04/09/2021 Letter INSPECTION SUMMARY
04/20/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter INSPECTION SUMMARY
04/28/2021 Lot 53 Stoney Creek Structural Letter
04/29/2021 Letter INSPECTION SUMMARY
05/03/2021 MN53 column pad approval letter
05/06/2021 Letter INSPECTION SUMMARY
05/14/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/29/2021 Receipt Receipt for transaction:2021-006058
08/05/2021 Letter INSPECTION SUMMARY
08/05/2021 Letter Field Certificate of Occupancy
08/05/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home