Permit Application Status

PRRES20204543


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204543
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
12/01/2020
12/21/2020
07/23/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOSH@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 12/18/2020 12/16/2020
Shannon McGuire
Plot Plan Review Approved 12/04/2020 12/14/2020
Kim Brennan
Residential Plan Review Approved 12/04/2020 12/02/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,266.08 $1,266.08 Paid 12/16/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/16/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/16/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/16/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/16/2020
8331507-Sewer Connection Fee $510.00 $510.00 Paid 12/16/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/5/2021 01/20/2021
Misc
Informational
01/20/2021
-3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL - - UFER LOCATED IN NE REAR LEFT CORNER OF GARAGE FOUNDATION WALL -
Underslab Plumbing Inspection - Residential Passed 1/22/2021 1/22/2021 01/22/2021
Misc
Corrective Action Required
01/22/2021
- PROVIDE ADDRESS -
Piers/Caissons Inspection - Residential Passed 2/26/2021 (8:15) 2/26/2021 02/26/2021
Misc
Informational
02/26/2021
(2) 24 x 36 w/ (4) # 4 vert bars
Sewer Service Inspection - R Passed 3/11/2021 3/11/2021 03/11/2021
Water Service Inspection - R Passed 3/11/2021 (10:00) 3/11/2021 03/11/2021
Erosion Control Inspection Residential Failed 3/18/2021 03/18/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/18/2021
- PROVIDE SILT FENCE AT BERM IN BACK YARD - - MAINTAIN SILT FENCE SOUTH SIDE - - CLEAN UP TRASH BLOWING IN NEIGHBORS YARDS- - EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -
Erosion Control Inspection Residential Failed 3/23/2021 03/23/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/18/2021
- PROVIDE SILT FENCE AT BERM IN BACK YARD - - MAINTAIN SILT FENCE SOUTH SIDE - - CLEAN UP TRASH BLOWING IN NEIGHBORS YARDS- - EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -
All Rough Inspection - Residential Failed 3/23/2021 3/23/2021 03/23/2021
Misc
Corrective Action Required
03/23/2021
- EROSION CONTROL FAILED 3/18/21 - - MAINTAIN SILT FENCE - - ROUGH IN INSPECTION DENIED -
Gas Service Inspection - Residential Failed 3/24/2021 03/24/2021
Misc
Corrective Action Required
03/24/2021
- PROVIDE MIN 8 PSI FOR 15 MIN -
Electrical Service Inspection Passed 3/24/2021 3/24/2021 03/24/2021
All Rough Inspection - Residential Failed 3/24/2021 3/24/2021 03/24/2021
Misc
Resolved
03/24/2021
- EROSION CONTROL FAILED 3/18/21 - - MAINTAIN SILT FENCE - - ROUGH IN INSPECTION DENIED -
Misc
Corrective Action Required
03/24/2021
PROVIDE ENGINEERS LETTER FOR DAMAGED TRUSS A-12 MASTER BED AT HVAC / B VENT - - PROVIDE 1 ROOF VENT @ COVERED PATIO PER PLAN (4.00) - - SEAL UPWARD PENETRATIONS TOP PLATE AT SGD & KITCHEN SINK - - PROVIDE BOCA PLATE @ WATER LINE FOR REFRIGERATOR - - PROVIDE SOLID BLOCKING @ SHEATHING BREAKS GARAGE @ FRONT STOOP -
All Rough Inspection - Residential Failed 3/26/2021 3/26/2021 03/26/2021
Misc
Corrective Action Required
03/24/2021
PROVIDE ENGINEERS LETTER FOR DAMAGED TRUSS A-12 MASTER BED AT HVAC / B VENT ( nail per engineers letter) - PROVIDE 1 ROOF VENT @ COVERED PATIO PER PLAN (4.00) - Ok to insulate DO NOT SHEETROCK UNTIL TRUSS REPAIR NAILING RE-iINSPECTED
All Rough Inspection - Residential Passed 3/29/2021 3/29/2021 03/29/2021
Misc
Resolved
03/29/2021
Driveway Inspection Partial 4/29/2021 4/29/2021 04/29/2021
Misc
Informational
04/29/2021
4-29-21 1:52pm The forms are set and the aggregate is compacted. They will need to stay ADA compliant.
Gas Service Inspection - Residential Passed 5/6/2021 5/6/2021 05/06/2021
Misc
Corrective Action Required
03/24/2021
- PROVIDE MIN 8 PSI FOR 15 MIN -
Driveway Inspection Passed 5/7/2021 5/7/2021 05/07/2021
Misc
Informational
04/29/2021
4-29-21 1:52pm The forms are set and the aggregate is compacted. They will need to stay ADA compliant.
Misc
Informational
05/07/2021
Finished driveway meets LS and ADA specs. RP 5-7-21
Occupancy Inspection - Codes Residential Failed 6/9/2021 6/9/2021 06/09/2021
Misc
Corrective Action Required
06/09/2021
Maintain silt fence until sod complete Sidewalk inspection pending Provide final grade, sod, splash blocks Provide irrigation permit Provide blocking at cantilever near main service panel Basement handrail height measured vertically from the slopes plane adjoining the stair nosing shall be not less than 34" and not more than 38" R311.7.8.1 2018 IRC
Erosion Control Inspection Residential Failed 6/9/2021 06/09/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/23/2021
- PROVIDE SILT FENCE AT BERM IN BACK YARD - - MAINTAIN SILT FENCE SOUTH SIDE - - CLEAN UP TRASH BLOWING IN NEIGHBORS YARDS- - EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/09/2021
- MAINTAIN SILT FENCE UNTIL SOD COMPLETE - DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Sidewalk Inspection Partial 6/14/2021 6/14/2021 06/14/2021
Misc
Informational
06/14/2021
6/14/21 15:25- Crew has rock tampered down, sidewalk is 4in depth, 5 ft from the back of the curb and carried 2% or less.
Sidewalk Inspection Passed 6/18/2021 6/18/2021 06/18/2021
Misc
Informational
06/14/2021
6/14/21 15:25- Crew has rock tampered down, sidewalk is 4in depth, 5 ft from the back of the curb and carried 2% or less.
Misc
Informational
06/18/2021
6/18/21 9:00- Sidewalk is carrying the correct %, has the correct cure, and meets ada specs.
Plot Plan Inspection Passed 7/23/2021 07/23/2021
Deck Final Inspection - Residential Passed 7/23/2021 07/23/2021
Occupancy Inspection - Codes Residential Full C of O 7/23/2021 7/23/2021 07/23/2021
Misc
Resolved
07/23/2021
Documents & Images
Date Uploaded File Type Document Name
12/01/2020 Application Form Permit Application and License Tax Form
12/02/2020 Approved Plans Approved Truss Layout
12/02/2020 Approved Plans Approved Truss Package
12/11/2020 Approved Plans Approved Drawings
12/14/2020 Plot Plan Approved Plot Plan
12/16/2020 Receipt Receipt for transaction:2020-008061
12/21/2020 Letter DS Building Permit
01/20/2021 W2 Lot 3 - 103 nw Grady Ct-- Footing inspection
01/20/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
02/26/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/18/2021 Letter INSPECTION SUMMARY
03/18/2021 Letter INSPECTION SUMMARY
03/23/2021 Letter INSPECTION SUMMARY
03/23/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/26/2021 Engineer Report/Study Truss Repair letter
03/26/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
04/29/2021 Letter INSPECTION SUMMARY
05/06/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter Field Certificate of Occupancy
07/23/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home