Summary
PRRES20203857
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED PATIO - FINISHED BASEMENT
10/21/2020
10/23/2020
04/20/2021
06/25/2021
Locations
Contacts
ASPEN HOME BUILDERS LLC, Address:6618 ROYAL ST #B, Phone:(816) 507-0123  
STEVE@ASPENHOMESKC.COM  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/23/2020 10/22/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
10/22/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 10/23/2020 10/22/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,188.91 $1,188.91 Paid 10/22/2020
8331507-Sewer Connection Fee $480.00 $480.00 Paid 10/22/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 10/22/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 10/22/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/22/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/22/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/3/2020 (11:30) 11/3/2020 11/03/2020
Erosion Control Inspection Residential Failed 12/08/2020
Misc
Corrective Action Required
12/08/2020
-Erosion control requires continuous maintenance. Repair damaged sections at curb line and establish methods at rear property line within two business days -street cleanup required
Underslab Plumbing Inspection - Residential Passed 12/8/2020 12/8/2020 12/08/2020
Erosion Control Inspection Residential Failed 01/20/2021
Misc
Corrective Action Required
12/08/2020
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -no further inspections until issues are resolved
Sewer Service Inspection - R Passed 1/26/2021 (1:00) 1/26/2021 01/26/2021
Water Service Inspection - R Partial 1/27/2021 (10:15) 1/27/2021 01/26/2021
Misc
Informational
01/26/2021
Partial approval from structure to metallic connection customer side of meter
Water Service Inspection - R Passed 01/27/2021
Misc
Resolved
01/27/2021
Partial approval from structure to metallic connection customer side of meter
Erosion Control Inspection Residential Passed 02/04/2021
Misc
Resolved
02/04/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -no further inspections until issues are resolved
Gas Service Inspection - Residential Passed 2/24/2021 2/24/2021 02/24/2021
Electrical Service Inspection Passed 2/24/2021 2/24/2021 02/24/2021
All Rough Inspection - Residential Partial 2/24/2021 2/24/2021 02/24/2021
Misc
Corrective Action Required
02/24/2021
-Stem wall line X from 18 to 20, line 20 from X to V, line V from 20 to 21
Misc
Corrective Action Required
02/24/2021
-Stem wall line X from 18 to 20, line 20 from X to V, line V from 20 to 21, line 21 from V to W, line W from 21 to 23
Piers/Caissons Inspection - Residential Passed 02/24/2021
All Rough Inspection - Residential Failed 2/24/2021 2/24/2021 02/24/2021
Misc
Corrective Action Required
02/24/2021
-Provide erosion control at side of lot -Nail exterior sheathing per plan throughout -Unable to verify exterior nailing pattern on studs and header at PFH -Provide 2 rows of 16d nails 3” OC at top plate to header connection at PFH -Fireblock at soffit line at duct chase -Studs bored over 40% in exterior wall at garage by electrical panel -Nail all corners and intersecting walls per code -Replace cut stud at exterior corner of dining room -Seal dead space at laundry -Joist hangers at bathroom near bed 3 -Provide lateral brace for (2) 2x8 beam at stairwell -Add bearing stud for roof bearing at master/ stairwell wall
Misc
Resolved
02/24/2021
All Rough Inspection - Residential Failed 3/1/2021 3/1/2021 03/01/2021
Misc
Corrective Action Required
02/24/2021
-Nail exterior sheathing per plan throughout -Studs bored over 40% in exterior wall at garage by electrical panel, provide stud shoe -Nail all corners and intersecting walls per code -complete electrical installation from stud repair in dining room
All Rough Inspection - Residential Passed 3/2/2021 3/2/2021 03/02/2021
Misc
Resolved
03/02/2021
-Nail exterior sheathing per plan throughout -Studs bored over 40% in exterior wall at garage by electrical panel, provide stud shoe -Nail all corners and intersecting walls per code -complete electrical installation from stud repair in dining room
Driveway Inspection Passed 4/22/2021 4/22/2021 04/27/2021
Misc
Informational
04/27/2021
The diveway has been poured and had passed inspections.
Sidewalk Inspection Passed 4/22/2021 4/22/2021 04/27/2021
Miscellaneous Correction
Informational
04/27/2021
Tom Taylor looked at the sidewalk and it appears to have met the standards to pass.
Plot Plan Inspection Failed 5/11/2021 05/11/2021
Misc
Corrective Action Required
05/11/2021
Complete manhole riser installation
Occupancy Inspection - Codes Residential Failed 5/11/2021 5/11/2021 05/11/2021
Misc
Corrective Action Required
05/11/2021
-Maintenance of erosion Control Methods is Required until sod is in place -Downspouts to discharge minimum 36 inches from foundation -Seal exterior penetrations -Guard rail required where grade below exceeds 30 inches, front stoop -No building address, minimum 4 inch height, half inch stroke, on contrasting background and in illuminated area -Provide joist hangers at Garage landing. Address improper stair rise at landing in garage, complete guard rail installation & open risers may not exceed 4 inches -Install anti-tip device at range -Complete safety glaze shower enclosure, master bath
Occupancy Inspection - Codes Residential Temporary C of O 5/13/2021 5/13/2021 05/12/2021
Misc
Corrective Action Required
05/11/2021
-Maintenance of erosion Control Methods is Required until sod is in place -Downspouts to discharge minimum 36 inches from foundation TCO VALID THROUGH June 12, 2021
Occupancy Inspection - Codes Residential Failed 6/11/2021 6/11/2021 06/11/2021
Misc
Corrective Action Required
05/12/2021
-Downspouts to discharge minimum 36 inches from foundation TCO VALID THROUGH June 12, 2021
Plot Plan Inspection Passed 6/11/2021 6/11/2021 06/11/2021
Misc
Corrective Action Required
05/11/2021
Complete manhole riser installation
Occupancy Inspection - Codes Residential Full C of O 6/25/2021 6/25/2021 06/25/2021
Misc
Resolved
06/25/2021
-Downspouts to discharge minimum 36 inches from foundation TCO VALID THROUGH June 12, 2021
Documents & Images
Date Uploaded File Type Document Name
10/21/2020 Application Form Permit app Lot 739 EC
10/21/2020 Lot 739 EC plot plan
10/21/2020 Birch plans lot 739 EC
10/22/2020 Plans APPROVED HOUSE PLANS
10/22/2020 Letter Codes Residential Plan Review
10/22/2020 Plot Plan APPROVED PLOT PLAN
10/22/2020 Receipt Receipt for transaction:2020-007138
10/23/2020 Letter DS Building Permit
11/03/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter Codes Residential Plan Review
12/08/2020 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/26/2021 Lot 739 EC pier inspection
01/27/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
03/01/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
04/26/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter INSPECTION SUMMARY
05/08/2021 LOT 739 ASBUILT
05/10/2021 Plot Plan APPROVED PLOT PLAN
05/11/2021 Letter INSPECTION SUMMARY
05/11/2021 Letter INSPECTION SUMMARY
05/11/2021 Letter INSPECTION SUMMARY
05/11/2021 Letter INSPECTION SUMMARY
05/12/2021 Letter Codes Temporary Certificate of Occupancy
06/11/2021 Letter INSPECTION SUMMARY
06/11/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter Codes Final Certificate of Occupancy
06/25/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home